Showing 1 to 20 of 20 for “"Line-Commutated Converter"”.
-
Modeling line-commutated converter HVDC transmission systems using dynamic phasors
… thesis develops the dynamic phasor model of a line-commutated converter (LCC) high-voltage direct current (HVDC) transmission system. The mathematical definition and properties of dynamic phasors are utilized to model both the dc-side and the ac-side of a LCC-HVDC transmission system as well as …
-
Generalized dynamic average modeling of line-commutated converter systems in transient simulation programs
Power electronic converters are used in a wide range of applications as well as being the enabling technology for interfacing the alternative energy resources and many loads in modern power systems. The methodology of developing the so-called dynamic average-value models (AVMs) for such converters …
-
Variable speed constant frequency power conversion with permanent magnet synchronous and switched reluctance generators
… power conversion stage may be a dc link with a line-commutated converter, a dc link with a self-commutated inverter, or a cycloconverter. The line-commutated converter and cycloconverter power stages require a fixed frequency supply for operation whereas the self-commutated inverter is capable …
-
Travelling Wave Based DC Line Fault Location in VSC HVDC Systems
… based fault location techniques work well for line commutated converter (LCC) based high voltage direct current (HVDC) transmission lines, but the large capacitors at the DC line terminals makes application of the same techniques for voltage source converter (VSC) based HVDC schemes …
-
A Hybrid LCC-VSC HVDC Transmission System Supplying a Passive Load
… grids, stability of long transmission lines, and use of long cables for power transmission. In the past 20 years, Voltage Source Converter (VSC)-HVDC transmission systems were developed and installed in many projects, thereby adding more operational benefits to DC transmission option, …
-
Series / Parallel Hybrid VSC-LCC for HVdc Transmission Systems
… thesis investigates the feasibility of hybrid converter based arrangements for High Voltage direct current (HVdc) transmission systems. The conventional HVdc transmission systems, which use Line Commutated Converter (LCC) technology, require ac voltage and large amounts of reactive power to …
-
Extended-frequency dynamic phasor modelling of LCC-HVDC systems for electromagnetic transient simulations
A new model for line-commutated converter (LCC) HVDC systems based upon the concept of extended-frequency dynamic phasors is developed in an electromagnetic transient (EMT)-based simulation platform. The proposed model is capable of representing LCC-HVDC converters during normal as well as abnormal …
-
Multi-terminal HVDC (MTHVDC) interaction studies using small signal stability assessment
… modern power systems. Tapping on existing HVDC lines becomes a practical option to deliver reliable power to the customer. However, there are potential interactions in the Multi-terminal HVDC (MTHVDC) systems. To investigate the interactions in MTHVDC systems, a detailed linearized Line …
-
LCC Based Multi-Terminal HVDC Operation without Telecommunication
… in the last two decades. Nowadays, a Line-Commutated Converter (LCC) HVDC is a dominant technology for high power transmission over long distances. Typically, point-to-point configuration HVDC systems are used. However, in a case when generated electricity has to be supplied to several …
-
Control and modeling of a hybrid quasi-three-level converter for high voltage direct current applications
… to their widespread implementation. High power converters are vital components of these systems, and the continued analysis of existing and novel topologies is crucial to their increased efficacy and deployment. The voltage source converter, based on self-commutating semiconductors, encompasses …
-
Transient overvoltages caused by a monopolar fault on a bipolar dc overhead line with dedicated metallic return
… fault on pole conductor in an overhead bipolar Line Commutated Converter (LCC) HVdc system with a Dedicated Metallic Return (DMR). In HVdc systems with earth return, when a fault occurs, one pole may be lost causing the system to operate in monopolar mode with the ground return. During the …
-
Proteção de linhas de transmissão aéreas de sistemas LCC-HVDC monopolares baseada em ondas viajantes utilizando um terminal
… the conventional direct current transmission lines systems, LCC (Line Commutated Converter) systems, present great lengths, which increase the fault occurrence rate and, consequently, the demands on the protection methods. A transmission line protection with fast actuation is indispensable, …
-
Power Electronics Converter Interfaced Power System Emulation Platform Development and Research Demonstration
… programming interconnected three-phase voltage converters (VSCs) to behave like the intended power system components.In this dissertation, several platforms are developed to extend the HTB emulation capability, including a versatile power electronics converter based transmission line emulator, a …
-
Design, Control and Protection of Modular Multilevel Converter (MMC)-Based Multi-Terminal HVDC System
… of remote renewable energy. Voltage source converter (VSC) type is preferred over the traditional line-commutated converter (LCC) for this application, due to the advantages like smaller station footprint and no need for strong interfacing ac grid. As the state-of-the-art VSC topology, …
-
A simulation-based optimisation method to evaluate dynamic compensators for the improvement of LCC-HVDC performance in high source impedance power systems
Line commutated converter (LCC) high voltage direct current (HVDC) link dynamic performance is negatively affected by low alternating current (AC) system short circuit ratio (SCR) as viewed from the LCC-HVDC link converter stations. This is particularly evident at LCC-HVDC link converter stations …
-
Commutation failure prediction and interaction mechanism of Multi-Infeed LCC-HVDC systems under asymmetrical faults
Line-Commutated Converter based HVDC (LCC-HVDC) systems have been widely used for long-distance bulk power transmission and will play a vital role in the future decarbonised power systems since renewable energy resources are normally far away from load centres. As a frequent dynamic event in …
-
An impedance frequency response approach for analyzing interactions in ac-dc systems
… level between the ac side system and dc side converters. The system resonances in the sub-synchronous and super-synchronous frequency range are identified and stability determined. This approach applies the Generalized Nyquist stability Criterion (GNC) assuming that the frequency dependent …
-
Modeling and Control of Wind Generation and Its HVDC Delivery System
… Furthermore, a control scheme for rotor-side converter (RSC) and grid-side converter (GSC) is studied. A control method for the HVDC delivery system is also presented. Secondly, wind farms are prone to faults due to the remote locations. Unbalanced fault is the most frequent. Therefore, …
-
Hybrid AC/DC hubs for network connection and integration of renewables
… Toaddress the demands of connecting wind farm converter stations with other AC/DCsystems, different hybrid HVDC converters for network connection and integration ofrenewables are proposed and evaluated in this thesis with the consideration ofconverter power rating, cost, efficiency and …
-
Phase-Locked Loop Control In Low-Inertia Grid-Connected Voltage-Source Converters
… the grid increases, the number of voltage-source converters (VSC) installed also does. VSC controls both switch turn-on and turn-off, allowing a dc voltage source to be switched between phases. For the converter to accurately synchronize with the grid, a phase-locked loop (PLL) is used for the …