Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 56 for “"Linear Polarization Resistance"”.
-
The Effect of Sweep Rates on Linear Polarization Resistance Measurements
A study of Linear Polarizations Resistance Measurements for silver metal immersed in a solution of AgNO3 and HNO3 to determine the effect of varying potential sweep rates has been made. Results indicate that for the system under investigation the Polarization Resistance is a non-linear function of …
-
Assessment of In-situ Corrosion Conditions at Nevada Mechanically Stabilized Earth Wall Sites: Using Electrochemical Soil Characteristics and Linear Polarization Resistance
… electrochemical backfill characterization and linear polarization resistance (LPR) corrosion rate monitoring. Evaluation of electrochemical backfill characteristics has resulted in the discovery of six sites that fail current NDOT/ AASHTO MSE wall backfill requirements. The in-situ soil samples …
-
Avaliação de heterociclo do tipo mesoiônico solubilizado em sistema microemulsionado para aplicação em dutos
… inhibitors were evaluated by the techniques of linear polarization resistance (LPR) and loss of weight (MW) in a cell instrumented given the gravity and electrochemical devices. The systems were shooting speed of less than 60 minutes and efficiency of inhibition [SCO-ME (91.25%) and SCO-ME-MI …
-
Electrochemical Method for Characterization and Ranking of Corrosion Inhibitors
… the potential corrosion inhibitors through linear polarization resistance (LPR) testing in NaCl electrolyte, narrowing the collection of inhibitors to the three most-promising chemicals, adrenalone, 3,4-dihydroxyphenylacetic acid and dopamine. The screened inhibitors proved effective in HCl …
-
An Investigation into the Micromechanical and Corrosion Properties of Additively Manufactured Stainless Steel 316L
… micro-mechanical properties and corrosion resistance of laser powder bed fusion (L-PBF) processed additive manufactured (AM) 316L stainless steel parts were investigated for different combinations of processing parameters. Various laser powers were employed for the fabrication of all AM …
-
Utilização de matérias primas vegetais para aplicabilidade como inibidores de corrosão
… were performed by the electrochemical linear polarization resistance (LPR) technique as well as weight loss, on the surface of AISI 1020 carbon steel. The maximum corrosion inhibition efficiencies were determined by extrapolation of Tafel plots, showing the following values: 95,6 % for …
-
Understanding Tribocorrosion of Pipeline Steels: Measuring the Impact of Hydraulic Fracturing Fluid Additives on Material Loss
… including, open circuit potential (OCP), linear polarization resistance (LPR), and potentiodynamic polarization. Evaluation of the wear generated in tribocorrosion experiments was accomplished through optical profilometry and scanning probe microscopy. Scanning electron microscopy (SEM) …
-
EVALUATION OF THE EFFECT OF THE pH OF CONCRETE PORE SOLUTION ON THE CORROSION PERFORMANCE OF REINFORCING BARS
… pH of concrete pore solution on the corrosion resistance of reinforcement is evaluated using the rapid macrocell test (outlined in Annex A2 of ASTM A955-14). Tests are conducted on five different types of reinforcing bars; Type 2304 duplex stainless steel bar, Type 304 stainless steel clad bar, …
-
Reavaliação da eficiência de óleo de coco saponificado e de sua microemulsão como inibidores de corrosão em uma célula eletroquímica
… instrumented cell, via techniques involving linear polarization resistance (LPR) and mass loss coupons (MLC). For this, curves of efficiency versus SCO concentration (ranging between 0 and 75 ppm) have been constructed. According to the obtained results, the following efficiency levels were …
-
Nondestructive Evaluation Of Corrosion Damage In Reinforced Concrete Aged Slab Specimen
… rate were estimated with half-cell potential and linear polarization resistance measurements. Impact-echo and ultra-sonic pulse velocity tests were conducted periodically to assess concrete damage. Corrosion losses required to initiate cracks were estimated. At the end of the test period, results …
-
Desgaste corrosivo-cavitativo-erosivo de um aço-carbono em meio aquoso com frações de sal (NaCl), CO2 e particulados sólidos (SiO2)
… (180°) by Profilometry, Mass Variation and Linear Polarization Resistance (LPR). The results of the Microhardness and Surface Texture of all coupons were subjected to statistical comparison, using the software Statgraphics® Centurion XVI, 95% statistical certainty, and significant …
-
Stress corrosion cracking behavior of friction stir processed ultrafine grained light metal alloys
… to the base alloy. The significant increment in linear polarization resistance of UFG Al-Mg-Sc alloy has been attributed to modification in chemistry and grain refinement. The slow strain rate testing (SSRT) results indicated no stress corrosion susceptibility for FSP Al-Mg alloy. A critical …
-
Obtenção de novos sistemas nanoautoemulsificantes a partir do óleo das sementes de Azadirachta indica A Juss e suas aplicações como inibidores de corrosão
… Juss (SNEOAI) was evaluated by the techniques of linear polarization resistance (LPR) and weight loss (CPM), a instrumented cell. For that, hydroalcoholic extract of leaves of A. indica (EAI) was solubilized in a nanoemulsion system (SNEOAI) of which O/W system (rich in aqueous phase). This …
-
Bench- and Pilot-Scale Corrosion Control Inhibitor Effectiveness Studies for a Community's Blended Surficial and Brackish Groundwater Supply
… City's existing finished water corrosivity using linear polarization resistance (LPR) measurements and gravimetric coupon analysis at the pilot-scale, during which four phosphate-based inhibitors were tested for corrosion control. Based on the initial screening results, the City challenged UCF to …
-
Evaluation of Corrosion Detection Methods in Reinforced Concrete Structures
… techniques analyzed include half-cell potential, linear polarization resistance, galvanostatic pulse technique, connectionless electronic pulse response analysis and four-point electrical resistivity. Generally, corrosion rate as determined by NDT measurements is in agreement, to the same order of …
-
The influence of Arabian Gulf environment on mechanisms of reinforcement corrosion
… analysis, scanning electron microscopy, DC linear polarization resistance and AC impedance spectroscopy techniques were utilized to study the effect of experimental parameters on chloride binding, reinforcement corrosion and carbonation.The results indicated that the concomitant presence of …
-
Derivado de oxazinoquinoxalina e sistemas coloidais à base de óleo de coco aplicados como inibidores de corrosão em aço AISI 1018 em meio salino
… AISI 1018, in saline (3.5% NaCl). Studies of Resistance Polarization Linear (RPL) showed inhibition efficiencies ranging from 55% to 89% in low concentrations (6 pmm to 100.0 ppm) evaluated samples (OAQX) solubilized in DMSO. For determination of adsorption parameters, Langmuir isotherms were …
-
Avaliação da eficiência da espécie vegetal ouratea parviflora como inibidor de corrosão em aço carbono
… a saline medium (NaCl 3.5%). Was used the method Linear Polarization Resistance method, also determining the behavior and the isotherm of the metal/inhibitor adsorption process. According to the obtained results, the maximum inhibition efficiencies were observed at 67.70% (12.5 ppm), 77.94% (200 …
-
Corrosion of Post-Tensioned Tendons Repaired with Dissimilar Grout
… was monitored through macrocell current, linear polarization resistance, open circuit potential, potentiodynamic scans, and electrochemical impedance spectroscopy. Samples in simulated pore solutions were studied at various pH levels and constituent concentrations. All samples were …
-
Contributors to waterside corrosion of soil-steel structures
… to determine the properties causing degradation. Linear polarization resistance was also completed on two mechanically stabilized earth walls to obtain in-situ corrosion rates. To complement field work, laboratory experiments were conducted on galvanized steel samples in electrolytes simulating …
Page 1 of 3