Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 331 for “"Linear accelerator"”.

  1. A linear accelerator bunch length monitor

    The Saskatchewan Accelerator Laboratory is a 300 MeV electron accelerator (Linac) and storage ring. Electrons are injected into the Linac in packets called bunches for acceleration by an electromagnetic field. The length of these bunches have a direct impact on the energy spread of the beam at the …

    sask Repository record for A linear accelerator bunch length monitor (opens in a new tab)

  2. Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning

    Beam commissioning is a critical component of linear accelerator (LINAC) implementation, requiring accurate measurement of percent depth dose (PDD), beam profiles, and output factors across a wide range of field sizes. Conventional commissioning workflows often require multiple detectors and can be …

    vcu Repository record for Medical Linear Accelerator Water Tank Measurements Optimization for Commissioning (opens in a new tab)

  3. Neutron production and transport at a medical linear accelerator

    … Teaching Hospital (VTH) uses a Varian Trilogy™ linear accelerator (linac) for radiation oncology treatment. The high-energy electron beam is used to treat superficial tumors (deep tissues are spared with this modality) or is accelerated against a target to produce high-energy photons that are …

    colostate Repository record for Neutron production and transport at a medical linear accelerator (opens in a new tab)

  4. Measurement of the bremsstrahlung spectrum of the linear accelerator.

    … to monitor the bremastrahlung beam of the MIT linear accelerator has been designed and tested. This spectrometer measures the energy distribution of the photo protons from deuterium. The bremastrahlung spectrum is found by using the known cross section for the d( ,n)p reaction. The efficiency …

    nps Repository record for Measurement of the bremsstrahlung spectrum of the linear accelerator. (opens in a new tab)

  5. Gas target studies at the Naval Postgraduate School linear accelerator.

    … targets at the Naval Post- graduate School Linear Accelerator v/as conducted. The parameters included gas densities, effective target thicknesses, and radiative corrections to experimental cross-section calculations. To compare the NPGLINAC with other accelerators an electron scattering …

    nps Repository record for Gas target studies at the Naval Postgraduate School linear accelerator. (opens in a new tab)

  6. Energy Recovery Linear Accelerator Lattice Design and Coherent Synchrotron Radiation

    Energy Recovery Linear Accelerators (ERLs) are potential drivers for novel fourth-generation synchrotron light sources. An ERL combines the high quality beams of a linear accelerator with the high currents possible in a storage ring. The excessive power needs of a lone linac are avoided by …

    cornell Repository record for Energy Recovery Linear Accelerator Lattice Design and Coherent Synchrotron Radiation (opens in a new tab)

  7. Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator

    … on three clinically beam matched Varian iX linear accelerators. Measurements of the beam quality (%DD(10)), peak-to-valley dose ratio (PVDR), collimator factor (CF), and relative output factor (OF) were carried out for 2 cm x 2 cm, 3 cm x 3 cm, 4 cm x 4 cm, and 5 cm x 5 cm mini-beam …

    sask Repository record for Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator (opens in a new tab)

  8. Measurement of Neutron Activation from a High Energy Varian Linear Accelerator

    Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced …

    unlv Repository record for Measurement of Neutron Activation from a High Energy Varian Linear Accelerator (opens in a new tab) Download PDF for Measurement of Neutron Activation from a High Energy Varian Linear Accelerator (opens in a new tab)

  9. Exploration of an electron linear accelerator-driven photoneutron source for BNCT

    … the experiment. Changes to the settings of the linear accelerator used were also made. These changes resulted in the desired increased neutron output from the system.

    missouri Repository record for Exploration of an electron linear accelerator-driven photoneutron source for BNCT (opens in a new tab)

  10. Design and simulation of the Colorado State University linear accelerator system

    … of Twente in the Netherlands recently donated a linear accelerator and free-electron laser system to Colorado State University. A detailed model and simulation of the system must be constructed in order to assist the re-commissioning process at CSU. An initial design of the beam-transport system …

    colostate Repository record for Design and simulation of the Colorado State University linear accelerator system (opens in a new tab)

  11. A facility for transient radiation effects experiments at the NPS linear accelerator

    … to give time and spatial beam profiles which aid linear accelerator tuning and beam manipulation is described. Initial transient radiation effects experiments have been conducted and photo currents observed. Schematics, pictures, and construction details of the apparatus are presented.

    nps Repository record for A facility for transient radiation effects experiments at the NPS linear accelerator (opens in a new tab)

  12. Wakefield Damping in a Distributed Coupling Linear Accelerator for the Compact Linear Collider

    Particle accelerators are made of series of metal coupled pillbox cavities. The dimensions of the cavities are tuned to resonate at a particular frequency when excited by radio frequency (RF) waves. This thesis studies a new accelerator design for the Compact Linear Collider (CLIC). The number of …

    sask Repository record for Wakefield Damping in a Distributed Coupling Linear Accelerator for the Compact Linear Collider (opens in a new tab)

  13. Instrumental photon activation analysis using the linear accelerator at the Naval Postgraduate School

    Charcoal, charcoal residue, potting soil, aluminum foil, bismuth germinate, and petroleum samples have been investigated using instrumental photon activation analysis (i.e., no radiochemistry). The major and minor elements routinely observed by this nondestructive method were: C, Cl, Ca, Fe, Mg, …

    nps Repository record for Instrumental photon activation analysis using the linear accelerator at the Naval Postgraduate School (opens in a new tab)

  14. The establishment of a radiation effects program at the NPGS linear accelerator facility.

    The establishment of a program to study the effects of radiation on solid state electronic devices is discussed. The design and testing of experimental equipment used in connection with this project, and the techniques developed for the exposure of devices to the electron beam of the NPGS LINAC, …

    nps Repository record for The establishment of a radiation effects program at the NPGS linear accelerator facility. (opens in a new tab)

  15. In-situ testing of radiation effects on VLSI capacitors using the NPS linear accelerator

    … testing is conducted using the NPS electron linear accelerator. The data is taken while the capacitor is being exposed to an accumulating dose of electron radiation. The capacitance values are monitored using the parameter changes of a specially designed low pass filter circuit. The 3 dB …

    nps Repository record for In-situ testing of radiation effects on VLSI capacitors using the NPS linear accelerator (opens in a new tab)

  16. Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques

    … emittance of the Naval Postgraduate School (NPS) Linear Accelerator (linac) has been measured: the normalized horizontal emittance of 97 pi +/- 10 pi mm-mrad and the normalized vertical emittance of 54 pi +/- 8 pi mm-mrad. The experiment was performed independently twice using a Kapton …

    nps Repository record for Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques (opens in a new tab)

  17. DEVELOPMENT OF A FOUR CAVITY SECOND-HARMONIC GYROKLYSTRON AS DRIVER FOR A LINEAR ACCELERATOR

    … designed specifically to drive a high gradient linear accelerator recently developed by the Haimson Corporation. The gyroklystron was designed using the code MAGYKL, yielding a predicted output power of 87 MW for an input drive power of 250 W, with a velocity pitch ratio (alpha) of 1.4. The tube …

    maryland Repository record for DEVELOPMENT OF A FOUR CAVITY SECOND-HARMONIC GYROKLYSTRON AS DRIVER FOR A LINEAR ACCELERATOR (opens in a new tab)

Page 1 of 17