Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"Linear attenuation coefficient"”.

  1. Development of a method for automating effective patient diameter estimation for digital radiography

    … for the image receptor. Values of effective linear attenuation coefficient are estimated from Monte Carlo simulations. Monte Carlo simulations were created for two x-ray systems. The simulations were optimised and thoroughly validated to ensure that any result obtained is accurate. The …

    dundee Repository record for Development of a method for automating effective patient diameter estimation for digital radiography (opens in a new tab) Download PDF for Development of a method for automating effective patient diameter estimation for digital radiography (opens in a new tab)

  2. Design and Fabrication of a Mechanical Device for "in-situ" Measurement of Density of a Wood Particle Mat during Pressing

    … and attached to the press through a series of linear bearings. Aluminum plate stock was used to fabricate a frame to which all racks, gears and yokes were attached. A teflon insulating pad was placed between all surfaces of the mechanical device and the press to minimize heat transfer to the …

    utk-theses Repository record for Design and Fabrication of a Mechanical Device for "in-situ" Measurement of Density of a Wood Particle Mat during Pressing (opens in a new tab)

  3. Investigation Of Barium Sulfate Sludge From Wastewater Treatment For Use In Concrete And Drilling Fluid Applications

    … is also investigated through measurements of its linear attenuation coefficient for gamma radiation from common industrial and medical radionuclides, including Ba-133, Co-60, and Cs-137. The dried waste material demonstrated potential as a partial replacement for portland cement in traditional …

    umn Repository record for Investigation Of Barium Sulfate Sludge From Wastewater Treatment For Use In Concrete And Drilling Fluid Applications (opens in a new tab)

  4. A Model for Technique Optimization of Dual Energy X-Ray Digital Imaging with Application to Intravenous Urography

    … at rates proportional to their density and linear attenuation coefficient. Therefore, the make-up of the object of interest can be resolved by irradiating it with multiple x-ray spectrums and then digitizing the resultant detected values and applying mathematical algorithms. The possible …

    marquette Repository record for A Model for Technique Optimization of Dual Energy X-Ray Digital Imaging with Application to Intravenous Urography (opens in a new tab)

  5. A X-ray scanning machine for imaging atomic elements

    … images which show the spatial variation of X-ray linear attenuation coefficient within an object. X-ray differential K absorbtion edge tomography is the application of computer axial tomography to form images of selected atomic elements within an object, and these images show the distribution of …

    dcu Download PDF for A X-ray scanning machine for imaging atomic elements (opens in a new tab)

  6. EFFECT OF MAGNETITE AND COLEMANITE ON RADIATION SHIELDING ULTRA-HIGH-PERFORMANCE CONCRETE

    … for density, compressive strength, and radiation attenuation (i.e., gamma, fast neutron, and thermal neutron). Results demonstrated that full replacement of silica sand with magnetite significantly enhanced mechanical and gamma shielding properties, while achieving the highest density (3420 kg/m³, …

    mcmaster Repository record for EFFECT OF MAGNETITE AND COLEMANITE ON RADIATION SHIELDING ULTRA-HIGH-PERFORMANCE CONCRETE (opens in a new tab)

  7. Spectral X-ray imaging using deep learning

    … and beyond. It operates by measuring the linear attenuation coefficient, which depends on photon energy. Traditional X-ray sources used in CT systems are polyenergetic, generating photons across a spectrum of energies. However, conventional CT systems rely on energy-integrating detectors …

    soton Download PDF for Spectral X-ray imaging using deep learning (opens in a new tab)

  8. DRY-WET PACKING OPTIMIZATION OF ULTRAHIGH-PERFORMANCE CONCRETE FOR RADIATION SHIELDING: UNVEILING THE INTERACTIVE EFFECTS OF MAGNETITE, ILMENITE, AND FERROBORON

    … on RS-UHPC performance, particularly gamma linear attenuation coefficient (µ). Among all models, the Random Forest and XG Boost models demonstrated superior predictive accuracy, achieving high R² values of 81% and 77%, respectively, and low error metrics. Lastly, an experimental program was …

    mcmaster Repository record for DRY-WET PACKING OPTIMIZATION OF ULTRAHIGH-PERFORMANCE CONCRETE FOR RADIATION SHIELDING: UNVEILING THE INTERACTIVE EFFECTS OF MAGNETITE, ILMENITE, AND FERROBORON (opens in a new tab)

  9. Reconstruction algorithms for multispectral diffraction imaging

    … intensity is measured to construct the spatial linear attenuation coefficient (LAC) distribution. Such scalar information is adequate for visualization of interior physical structures, but additional dimensions would be useful to characterize the nature of the structures. By imaging using …

    bu Repository record for Reconstruction algorithms for multispectral diffraction imaging (opens in a new tab)

  10. Experimental Determination of Shielding Requirements for PET Medical Facilities

    … A more accurate determination of the effective attenuation coefficient of lead for the spectra of photon energies emitted from PET/CT patients could reduce the shielding requirements necessary to adequately protect public health. In this work, the spectra of energies emitted from 14 patients of …

    uab Repository record for Experimental Determination of Shielding Requirements for PET Medical Facilities (opens in a new tab)

  11. The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation

    … us to investigate the benefits of reconstructing linear attenuation coefficient (mu) and (rho_e) images of the breast. First generation CT provides a cost-effective and simple approach to reconstruct (rho_e) images in a laboratory but is limited by the anisotropic probability of scatter, …

    manitoba Repository record for The Development and Validation of a First Generation X-Ray Scatter Computed Tomography Algorithm for the Reconstruction of Electron Density Breast Images Using Monte Carlo Simulation (opens in a new tab)

  12. Bone Densitometry using CT Imaging

    … beam hardening artifacts by decomposing the linear attenuation coefficient into two components. However, dual energy imaging requires a sophisticated hardware setup or extra radiation dosage in a CT examination and may introduce motion artifacts into the images and cause misregistration. A …

    nus Repository record for Bone Densitometry using CT Imaging (opens in a new tab) Download file for Bone Densitometry using CT Imaging (opens in a new tab)

  13. A study of the imaging of atomic elements by computerised axial tomography

    … images show the spatial variation in the linear attenuation coefficient in a cross-section of a specimen. However, no information is present to enable one to predict the location nor concentration of an atomic element in the image. Differential X-ray absorptiometry is a well established …

    dcu Download PDF for A study of the imaging of atomic elements by computerised axial tomography (opens in a new tab)

  14. Algorithms for enhanced artifact reduction and material recognition in computed tomography

    … source spectra and reconstruct the effective linear attenuation coefficient of voxels in the image which may not provide the sufficient information to identify the occupying materials. In this dissertation, we provide algorithmic solutions to enhance CT material recognition. We provide a set …

    bu Repository record for Algorithms for enhanced artifact reduction and material recognition in computed tomography (opens in a new tab)

  15. Comparative Performance Evaluation of Conventional and Folded Detector Structures for X-ray imaging

    … their good charge transport properties, higher attenuation coefficient and solution-based cheaper process techniques. These detectors need high detective quantum efficiency (DQE) for getting clear X-ray image. The photoconductor layer thickness plays a very important role in conventional …

    concordia Download PDF for Comparative Performance Evaluation of Conventional and Folded Detector Structures for X-ray imaging (opens in a new tab)

  16. A study of the imaging of contrast agents for use in computerised tomography

    … which is capable of mapping the variation in linear attenuation coefficient in a slice through an object. This is achieved by the multiple measurement of the attenuation of an X-ray beam at various positions and angles through the body. In medical diagnostic imaging using CT, contrast agents …

    dcu Download PDF for A study of the imaging of contrast agents for use in computerised tomography (opens in a new tab)

  17. Using X-ray Imaging Techniques to Determine Density of Foods

    … for evaluation of food density. The x-ray attenuation through materials is dependent on the chemical composition and is proportional to density as described by the Beer-Lambert's law. This relationship forms the hypothesis of this study. The proposed experiments were conducted to verify and …

    purdue-thes Repository record for Using X-ray Imaging Techniques to Determine Density of Foods (opens in a new tab)

  18. Limitations and Advancements in Soft x-ray Spectroscopy

    … through a high resolution XAS study of the linear polyacenes. When measured at high resolution, the linear polyacenes exhibited a fine structure that could be assigned to excitation of non-equivalent carbon atoms in the molecules. The energies and intensities of these transitions were …

    sask Repository record for Limitations and Advancements in Soft x-ray Spectroscopy (opens in a new tab)

  19. Alternating Minimization Algorithms for Dual-Energy X-Ray CT Imaging and Information Optimization

    … excitation energy. In turn, the estimates of the linear attenuation coefficients or the component images from dual-energy CT image reconstruction are usedto estimate the electron density and mean excitation. Therefore, the quantitative accuracy of the estimates of the linear attenuation …

    wustl Repository record for Alternating Minimization Algorithms for Dual-Energy X-Ray CT Imaging and Information Optimization (opens in a new tab)

  20. Měření stínicích vlastností materiálů

    Tato práce se věnuje problematice ionizujícího záření, konkrétně gama zářením a jeho stínění. Toto záření vzniká například při štěpné reakci v jaderném reaktoru. Ke stínění gama záření se nejčastěji používají materiály jako olovo nebo beton. Je to kvůli jejich nízké ceně a vysoké hustotě. Úkolem …

    brno-tech Repository record for Měření stínicích vlastností materiálů (opens in a new tab)

Page 1 of 2