Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 9 of 9 for “"Linearity correction"”

  1. CMOS techniques for direct digitisation of current signals

    … (CCRO) is presented which describes its non-linearity with a single parameter, the Active-to-Dead Time Ratio (TADR). An improved squaring CCRO topology is presented, based on the TADR model which improves upon the linearity of inverter-based CCROs by 9.75 dB. The power-linearity trade-off is …

    cork Repository record for CMOS techniques for direct digitisation of current signals (opens in a new tab) Embargoed until 2030-06-12

  2. Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease

    … response is non-linear. Aims: In this thesis non-linearity correction methods for quantitative myocardial DCE-MRI are compared, the feasibility of a novel bookend T1 based correction is tested and the method is used in clinical studies to assess myocardial characteristics in health and ischaemic …

    whiterose Repository record for Quantitative Dynamic Contrast Enhanced Magnetic Resonance Imaging for Evaluation of the Myocardium in Ischaemic Heart Disease (opens in a new tab)

  3. An Ultraviolet Survey of the DA White Dwarf Population of the Galaxy

    … We use white dwarfs within 100 pc to verify the linearity correction to the GALEX data. We find that the linearity correction is valid for magnitudes brighter than 15.95 and 16.95 for the far-ultraviolet (FUV) and near-ultraviolet (NUV) bands, respectively. We also use DA white dwarfs beyond 250 …

    oklahoma-thes Repository record for An Ultraviolet Survey of the DA White Dwarf Population of the Galaxy (opens in a new tab)

  4. Extending The Lifetime of Optically Stimulated Dosimeters For Use In Output Checks At Iroc- Houston

    … recommendations. Evaluations of sensitivity and linearity characteristics were performed as accumulated dose increased. To re-use the OSLDs, the dosimeters were bleached. Four different monochromatic and one polychromatic light source was compared to the IROC light source to determine the impact …

    uthsc Repository record for Extending The Lifetime of Optically Stimulated Dosimeters For Use In Output Checks At Iroc- Houston (opens in a new tab)

  5. Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry

    … performed with an 192Ir HDR source to determine correction factors for linearity with dose, dose rate, and the combined effect of irradiation energy and phantom construction. The uncertainties introduced by source positioning in the phantom and timer resolution limitations were also investigated. …

    uthsc Repository record for Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry (opens in a new tab)

  6. Optical metrology to support the next generation of nanopositioning

    … not always possible, or practical. Three novel correction algorithms are therefore proposed, aiming to correct for non-linearities in situations where existing correction algorithms fail. The first, the two-wavelength non-linearity correction aims to correct for higher order non-linearities in …

    cranfield Repository record for Optical metrology to support the next generation of nanopositioning (opens in a new tab)

  7. Phase distortion in envelope elimination and restoration radio frequency power amplifiers

    … of this research is to analyze and improve linearity of envelope elimination and restoration (EER) radio frequency (RF) power amplifiers. Envelope elimination and restoration was compared to other efficiency enhancement techniques and determined to likely be the most suitable solution for …

    gatech Repository record for Phase distortion in envelope elimination and restoration radio frequency power amplifiers (opens in a new tab)

  8. Variability of age of air derived from MIPAS SF₆ measurements

    … carried out, including a further developed non-linearity correction with simulated age of air spectra as opposed to the traditional method where an inverse Gaussian function was used to parametrise the age spectrum as a function of the mean age. Age of air trend patterns were found to be robust …

    karlsruhe-diss Repository record for Variability of age of air derived from MIPAS SF₆ measurements (opens in a new tab)

  9. Effects of luminance, color, and spatial frequency variations on perceived image quality

    … color variation is affected by the degree of non-linearity correction in the metric if the robustness is tested in the context of the straight-line relationship.

    vt Repository record for Effects of luminance, color, and spatial frequency variations on perceived image quality (opens in a new tab)