Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 197 for “"Liquid argon"”.
-
Electronic phenomena in liquid argon and liquid helium
… conduction pulses under alpha bombardment in liquid helium I and II, and a substantial extension of previous observations in liquid argon. Electron mobility in argon had been measured in fields between 2 kV/cm. and 200 kV/cm., the high field values agreeing with the order of magnitude …
-
Cosmic ray tests of a liquid argon calorimeter
A series of tests have been performed on a liquid argon calorimeter module at the Test Beam Facility at the Stanford Linear Accelerator Centre. We find that the calorimeter performs according to design. Several performance parameters have been measured. The charge-collection efficiency in a tower …
-
Development of a liquid argon purity monitoring system
Liquid argon time-projection chambers (LArTPCs) are used to detect charged particles and measure their properties. Charged particles that pass through the liquid argon (LAr) in a LArTPC ionize and excite argon atoms, producing ionization electrons and prompt scintillation light. The ionization …
-
Searching for Dark Matter With Single Phase Liquid Argon
… of WIMPs in terrestrial detectors. Single phase liquid argon detectors are an appealing WIMP detection technique due to the scintillation properties of liquid argon and the scalability of the single phase approach. The MiniCLEAN dark matter detector is a single phase liquid argon scintillation …
-
Interface Thermal Resistance Between Liquid Argon and Various Solids
… between two parallel solid walls separated by liquid argon is investigated using three-dimensional molecular dynamics (MD) simulations. Liquid argon molecules confined in silver and graphite nano-channels are examined separately. Heat flux and temperature distribution within the nano-channels …
-
Toward a Precision Measurement of CEvNS on Liquid Argon
… cross section on several targets. The first liquid argon measurement was made in 2021. The collaboration is currently undertaking precise measurements of the CEvNS cross section, the first of such measurements to be made on the liquid argon detector COH Ar 750. Making a precise measurement of …
-
Low-Energy Physics in Liquid Argon Time Projection Chambers
… an intense neutrino beam. Particles traversing liquid argon time projection chambers (LArTPCs) leave behind wakes of ionization electrons. DUNE, whose main components are LArTPCs, will image the topologies of these wakes with ~ 0.5 cm precision and ~500 ns timing resolution and, based on the …
-
Advancing the liquid-argon active veto for the LEGEND experiment
… suppression in this configuration is the liquid argon (LAr) instrumentation, which employs optical light-guide fibers to collect LAr scintillation light and veto background events via anti-coincidence with the high-purity germanium detector signals. This dissertation presents a dedicated …
-
Studying charge production in a liquid argon time projection chamber
Liquid Argon Time Projection Chambers (LArTPCs) have become widely used neutrino detectors. They primarily take advantage of the ionisation charge produced by the interaction of charged particles to achieve high spatial resolution and excellent calorimetry reconstruction. LArTPC is the technology …
-
Alphas and Surface Backgrounds in Liquid Argon Dark Matter Detectors
… This can be done using a scintillator such as liquid argon, which gives off light when a particle interacts with it. Liquid argon (LAr) is a favorable means of detecting WIMPs because it has an inherent property that enables a technique called pulse-shape discrimination (PSD). PSD can …
-
Measurement of the Dielectric Constants of Liquid Argon and Oxygen
Measurements of the dielectric constants of liquid argon, liquid oxygen, liquid nitrogen and three organic liquids were made with an alternating current series capacitance bridge operating over the frequency range from twenty cycles per second up to one hundred kilocycles per second. The liquefied …
-
Design and calibration of the dune liquid argon near detector
… Of these three detectors, the upstream Liquid Argon Time Projection Chamber (LArTPC) is considered to be the primary target due to its precision and similarity to the DUNE far detector units. The ND LArTPC detector will utilize novel detection techniques such as a highly-segmented drift …
-
A molecular dynamics investigation of a free surface of liquid argon
… the equilibrium molecular structure of the liquid-vapour interfacial region for argon at about 124 °K. The density profile through the surface is found to be of a non-monotonic form. The pair distribution function in the surface is also determined and compared to radial distribution …
-
Design of single phase liquid argon detectors for dark matter searches
… signal. This work explores the use of noble liquids, in a single liquid phase design, to detect single scatters of dark matter particles. The goal of current experiments is to investigate matter-dark-matter interaction cross-sections down to 10 -45 cm2 . With that in mind, the MiniCLEAN …
-
Reconstruction and Analysis for the DUNE 35-ton Liquid Argon Prototype
… the far detector will consist of 40 kton liquid argon and an embedded time projection chamber. This promising technology is still in development and, since each detector module is around a factor 15 larger than any previous experiment employing this design, prototyping the detector and …
Page 1 of 10