Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 17 of 17 for “"Liquid argon detector"”
-
First Search for Gravitational Wave Coincident Neutrinos in a Liquid Argon Detector with DEAP-3600
Modern liquid argon (LAr) scintillation detectors are capable of detecting many types of rare particle interactions with extremely low cross sections. One such detector, DEAP-3600, was originally designed to observe weak interactions between nuclei and dark matter; its low backgrounds and argon …
-
TOWARDS AN IMPROVED MEASUREMENT OF THE CEVNS PROCESS WITH THE CENNS-10 LIQUID ARGON DETECTOR
… and again in 2020 using a 24-kg single-phase liquid argon detector. Following the 2020 result, the liquid argon detector continued to operate, tripling the amount of data collected in the previous analysis. For this larger data set, beam-related neutron and steady-state backgrounds were …
-
Study of the calorimetric performance of a liquid Argon detector based on a novel optical imaging concept
… neutrino mass ordering. DUNE will exploit a Far Detector composed of four multi-kiloton LArTPCs, and a Near Detector (ND) complex located close to the neutrino source at Fermilab. The SAND detector at the ND complex is designed to perform on-axis beam monitoring, constrain uncertainties in the …
-
Study of the tracking performance of a liquid Argon detector based on a novel optical imaging concept
… An important component of the DUNE Near Detector complex is the System for on-Axis Neutrino Detection (SAND) apparatus, which will include GRAIN (GRanular Argon for Interactions of Neutrinos), a novel liquid Argon detector aimed at imaging neutrino interactions using only scintillation …
-
Simulations and Data analysis for the 35 ton Liquid Argon detector as a prototype for the DUNE experiment
… complex phase (δCP). DUNE will utilise Liquid Argon (LAr) Time Projection Chamber (TPC) (LArTPC) technology, and the Far Detector (FD) will consist of four modules, each containing 17.1 kt of LAr with a fiducial mass of around 10 kt. Each of these FD modules represents around an order of …
-
Comissioning and Calibration of a Small-Scale Modular Liquid Argon Detector, Argon-1, for Novel Studies in Background Rejection Techniques Towards Next-Generation Dark Matter Detectors
… sensitivity in next generation dark matter detectors will require the development of novel technologies, better background rejection and better understanding of noble liquid physics. To aid in this development, Argon-1 has been commissioned at Carleton University. Argon-1 is a modular …
-
Toward a Precision Measurement of CEvNS on Liquid Argon
… cross section on several targets. The first liquid argon measurement was made in 2021. The collaboration is currently undertaking precise measurements of the CEvNS cross section, the first of such measurements to be made on the liquid argon detector COH Ar 750. Making a precise measurement of …
-
A First Search for Coherent Elastic Neutrino-Nucleus Scattering with Liquid Argon
… that end, COHERENT has deployed the single-phase liquid argon detector CENNS-10 to provide a low $N$ measurement of the cross section. CENNS-10 completed an Engineering Run in the spring of 2017. From this analysis, a vital in-situ measurement of the beam-related neutron flux in liquid argon, …
-
Characterization of Pulse–Shape Discrimination for Background Reduction in the DEAP-1 Detector
DEAP (Dark Matter Experiment with Argon and Pulse Shape Discrimination) is an experiment that aims to directly detect dark matter particles via nuclear recoils in liquid argon. The experiment uses the scintillation property of liquid argon as a means to discriminate the γ and β backgrounds from the …
-
FIRST DETECTION OF COHERENT ELASTIC NEUTRINO-NUCLEUS SCATTERING ON AN ARGON TARGET
… Neutron Source (SNS) with a 14.6 kg CsI[Na] detector. One of the physics goals of the COHERENT experiment is to test the square of the neutron number dependence of the CEvNS cross section predicted in the Standard Model by observing CEvNS in multiple nuclei. To that end, the ~24 kg CENNS-10 …
-
MiniCLEAN Dark Matter Experiment
… The MiniCLEAN experiment is single-phase liquid-argon detector instrumented with 92 photomultiplier tubes placed inside the cryogenic liquid with 4-pi coverage of a 500 kg (150 kg) target (fiducial) mass. For this experiment, PMT stability and calibration are essential. In-situ optical …
-
Discovery potential for Heavy Neutral Leptons at the SAND detector of the DUNE experiment
… the Standard Model (BSM). At the DUNE Near Detector complex, the SAND detector will exploit the intense broadband neutrino beam and a high-resolution gas-detector tracker in a magnetic field coupled to a novel 1-ton liquid Argon detector and a high-granularity calorimeter to perform searches …
-
Phenomenology of a Low-Energy Neutrino Factory and Related Experiments
… physics reach of this setup with a 100 kiloton liquid argon detector and comparing its performance to that of a 50 kiloton liquid scintillator detector and a 440 kiloton water Cerenkov detector. The liquid argon and liquid scintillator detectors are found to perform best, providing sensitivity …
-
Design of single phase liquid argon detectors for dark matter searches
… signal. This work explores the use of noble liquids, in a single liquid phase design, to detect single scatters of dark matter particles. The goal of current experiments is to investigate matter-dark-matter interaction cross-sections down to 10 -45 cm2 . With that in mind, the MiniCLEAN …
-
Cosmic ray background estimations in large liquid argon detectors for proton decay via p to K+ anti_nu and nu_e appearance from nu_mu beams
… SD, have been proposed to house a large-scale liquid argon detector. This was once intended to be part of the ``Deep Underground Science and Engineering Laboratory" (DUSEL) project to build extensive laboratory space for multidisciplinary scientific research, well-shielded from cosmic rays. The …
-
Quasi-Background-Free Neutrinoless Double-Beta Decay Searches with LEGEND: Statistical Methods and Cryogenic SiPM Characterization
… deploying an array of highly enriched germanium detectors inside of a liquid argon cryostat. In order to fully cover the allowed parameter space for inverted ordered light Majorana neutrinos, the LEGEND collaboration is pursuing a phased approach. The already-built LEGEND-200 experiment aims for …
-
Étude et simulation de la lumière de scintillation produite et se propageant dans une chambre à dérive double-phase à argon liquide, dans le contexte du projet DUNE
… massif contenant plus de 40 kilotonnes d’argon liquide, basé sur la technologie des chambres à dérive à argon liquide (LArTPC). Deux approches de cette technologie sont actuellement en développement, menant à l'installation au CERN de deux prototypes dont la construction devrait s'achever …