Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 151 for “"Liquid samples"”.
-
Analysis of small volume liquid samples using cavity enhanced absorption spectroscopies
… sensitive absorption measurements on gas-phase samples, but their application to liquid samples has so far been more limited. Sensitive short pathlength analysis of liquid samples is required for online analysis of microfluidic samples, which are processed in channels with dimensions of tens to …
-
Trace element analysis of liquid samples, by proton induced x-ray fluorescence
A method of spectroscopic analysis of trace elements in solutions has been developed. The solution is converted to a mist and analyzed by proton induced x-ray flourescence in a helium atmosphere. Related problems in the development of proper droplet size and apparatus design are discussed in detail …
-
Thermal Characterization of Liquid Samples with Three-Dimensional On-Chip Micro Calorimeter
… diffusivity and specific heat capacity of liquid samples. These thermal properties are used to understand thermal reaction behavior, obtain information of stability for reactant molecules, and characterize a material. Thermally characterized solvents can be utilized to investigate a solute. …
-
A low-field nuclear magnetic resonance force microscope using liquid samples at room temperature
… Microscopy (NMRFM) studies of room-temperature liquids. A series of magnetically-capped oscillators was custom-made and characterized to form the core of the sensor. These were then employed in a novel probe with liquid samples and a sensor in vacuum, and used to study 1H resonance in a …
-
Effectiveness of a novel extraction method for semen: comparison using liquid samples and dried stains
… of time and resources. A large percentage of samples are mixtures containing DNA from a major female contributor and at least one minor male contributor. The amount of male DNA present is often much less than that of the female, making it difficult to achieve a full short-tandem repeat (STR) …
-
Design and Fabrication of a Nanofluidic Cell System for High-Resolution Electron Microscopy of in-Liquid Samples.
… an indispensable tool for the study of dry solid samples.[1,2] The use of a nanofluidic system (NFS) extends the applications of TEM to include wet solid, liquid, and gaseous samples, opening up a world of possibilities for the direct study of solution or gas phase reactions, dynamics of particles …
-
Microfluidic Viscometer for Tear Films and Other Biofluids
… and validated for measuring microliter-volume liquid samples, such as human tear films. The microfluidic viscometer combines an optically clear acrylic chip with a hydrophobic surface coating together with a syringe pump to control the sample flow rate. Additional functionally supporting …
-
Comparison of an Advanced Mercury Analyzer with the Cold Vapor Atomic Absorption Technique for the Determination of Mercury in Coal
… the AMA-254, for analysis of the solid and liquid samples. The system allows for the thermal heating of the sample to decompose the sample and release mercury, which is concentrated in a gold amalgam. Thermal desorption of the mercury from the amalgam is detected by atomic absorption …
-
Στοιχειακές και ισοτοπικές αναλύσεις ουρανίου σε υγρά δείγματα
… determination of uranium concentration in liquid samples. The present thesis describes the study, development, application and optimisation of practices that constituted the phosphorimetric apparatus of the laboratory a reliable technique for determining uranium concentration in liquid …
-
Overhauser effect and NMR spectra of n-methyl methylenimine
Pure liquid samples of the simple but rather reactive species N-Methyl Methylenimine were studied at -60°C. The conventional NMR spectra and double resonance spectra were taken. The NMR constants and relative signs of three spin-spin coupling constants were determined. Absolute signs of the …
-
Radiative cooling and optical temperature sensing
… by a factor of 92. With this approach various samples are cooled down radiatively and spatially structured cooling patterns are generated on their surfaces. First applications exploiting this cooling pathway even include the supercooling of liquids. In the second half of this thesis a novel …
-
Redesign and recalibration of a bubble-cap column used in the fractionation of isopropanol-water solutions
… an analytical method by which the composition of liquid samples from the column could be determined accurately and quickly, and, in general, to place the assembly in such condition that experimental runs can be made more easily with a higher degree of accuracy than has previously been possible.
-
The Nicotine Content of a Sample of E-cigarette Liquid Manufactured in the United States
… 2014 and 2019. There is little research on e-liquid nicotine concentration from domestic manufacturers. However, limited research outside of the U.S. found wide inconsistencies between the labeled concentration of nicotine in e-liquids and the actual nicotine concentration. Methods: The seven …
-
Terahertz Spectroscopy in Microfluidic Systems
… as a tool for the measurement of dry, solid samples, the investigation of liquid analytes is complicated by the strong attenuation of terahertz-frequency signals in aqueous environments. The integration of microfluidic systems with on-chip waveguides offers a potential solution as picosecond …
-
Application of phononic crystals as liquid sensors for the development of novel point of care technologies
… measurement of the acoustic properties of small liquid samples. So far, various phononic crystal sensors have been proposed to be used as liquid sensors. However, they are still in very early stages of development and suffer several drawbacks like high analyte consumption, complex manufacturing …
-
Microsecond and submicrosecond impulse breakdown of insulating liquids and liquid – polymer interfaces
… insulation within pulsed power machines; with liquid samples in varying levels of moisture saturation stressed with voltages of both standard and non-standard wave-shape to induce breakdown. To further reflect the practical scenario liquid samples were also tested when in direct contact with …
-
Microwave Properties of Liquids and Solids, Using a Resonant Microwave Cavity as a Probe
… determining microwave properties of solids and liquids. The method employed consisted of varying the depth of penetration of a cylindrical sample of the material into a cavity operating in the TM0 1 0 Mode. The liquid samples were contained in a thin-walled quartz tube. The perturbation of the …
-
Laser Electrospray Mass Spectrometry: Mechanistic Insights and Classification of Inorganic-Based Explosives and Tissue Phenotypes Using Multivariate Statistics
… laser pulses was measured using dried and liquid samples of p-substituted benzylpyridinium ions and peptides. In the comparison of the experiments of using 800 nm and 1042 nm laser pulses, it was found that there are different vaporization mechanisms for dried and liquid samples. It was …
-
Liquid Dielectrophoresis for Lab-on-Chip Detection and Bioanalysis
… microfluidics (DMF) refers to miniaturized liquid sample handling technology where biological/chemical samples are dispensed and further manipulated in the form of ultrafine droplets (microliter to picoliter), over micro/nano patterned surfaces. Liquid dielectrophoresis (L-DEP) based DMF …
Page 1 of 8