Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 429 for “"Liquid-liquid extraction"”.

  1. Liquid-liquid extraction in a spray column

    … in the continuous phase of a spray type liquid-liquid extraction tower. Concentration profiles of both continuous and dispersed phases were obtained by internal sampling. Mass transfer data are presented for the transfer of acetic acid between water and methyl isobutyl ketone in the …

    ubc Repository record for Liquid-liquid extraction in a spray column (opens in a new tab) Download PDF for Liquid-liquid extraction in a spray column (opens in a new tab)

  2. Technology for liquid-liquid extraction process development

    … The devices currently available for performing liquid-liquid separation steps at laboratory scale have limitations in performance, control and scalability. This thesis presents a new laboratory scale separation device that utilises nonwoven coalescing filters to separate challenging emulsion …

    whiterose Download PDF for Technology for liquid-liquid extraction process development (opens in a new tab)

  3. Liquid-Liquid Extraction by the Slug Technique

    … data on mass transfer coefficients in ternary liquid-liquid extraction. The technique yields a constant measurable interfacial area and the coefficients thus obtained from the experiments could be compared with those obtained by the penetration theory.</p> <p>The technique, as proposed, …

    mcmaster Repository record for Liquid-Liquid Extraction by the Slug Technique (opens in a new tab)

  4. Liquid-liquid extraction in a pulsed column

    Thesis (Ph. D.)--Michigan State University of Agriculture and Applied Science. Department of Chemical Engineering, 1957

    msu Repository record for Liquid-liquid extraction in a pulsed column (opens in a new tab)

  5. Back-mixing in liquid-liquid extraction spray columns

    Backmixing of the continuous phase was studied in liquid-liquid spray columns of various geometries, for various flowrates of the two phases, and for various drop size distributions. The dispersion or eddy diffusion model was used to characterize the axial mixing of the continuous phase. Axial …

    ubc Repository record for Back-mixing in liquid-liquid extraction spray columns (opens in a new tab) Download PDF for Back-mixing in liquid-liquid extraction spray columns (opens in a new tab)

  6. Individual mass transfer resistances in liquid-liquid extraction

    … measured by passing the two partially miscible liquids counter - currently through the column. The degree to which each stream approached saturation at the exit served as a measure of each film resistance. By presaturating one of the liquids, a unidirectional mass transfer was obtained and the …

    missouri Repository record for Individual mass transfer resistances in liquid-liquid extraction (opens in a new tab)

  7. The Modification of Solvents for Liquid-Liquid Extraction Processes

    … to modify the efficiency of selected solvents in liquid-liquid extraction by the addition of small amounts of additives would offer advantages in extraction, solvent recovery and inventory costs. Therefore, the literature relating to desirable solvent properties, variations in solvent use, methods …

    aston Repository record for The Modification of Solvents for Liquid-Liquid Extraction Processes (opens in a new tab) Download PDF for The Modification of Solvents for Liquid-Liquid Extraction Processes (opens in a new tab)

  8. Liquid-liquid extraction studies of the rare earth elements.

    … is directed towards the study of the solvent extraction behaviour of the lanthanides and aluminium, bismuth, calcium and zinc whose radii and/or charges are similar to those of the REE. A brief review of the fundamentals and classification of extraction systems and of extractants is presented …

    ottawa-retro Repository record for Liquid-liquid extraction studies of the rare earth elements. (opens in a new tab)

  9. Characteristics of a pulsed packed, liquid-liquid extraction column.

    … on the performance of a pulsed, packed, liquid extraction column, using the system benzoic acid, toluene, and water. Water was maintained as the continuous phase. It was found that in the range of parameters considered, that the higher the frequency of pulsation and the higher the water …

    nps Repository record for Characteristics of a pulsed packed, liquid-liquid extraction column. (opens in a new tab)

Page 1 of 22