Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 35 for “"Load Ratings"”.
-
The Effects of Truck Platoons on Steel Bridge Load Ratings
… or girder spacings. The AASHTO design and legal load ratings were calculated for each platoon case and were then used to examine the effects of truck platooning on bridge load ratings, and thus the adequacy of current bridges to carry platoons. The overall findings of the study include the …
-
Development of a Strategy to Address Load Posted Steel Multi-Girder Bridges Through Reduction in Uncertainty in Load Ratings
Bridges that are posted for load can cause a variety of issues for the people that use them and the entities that manage them. If a truck carrying goods must detour its route because it is too heavy to travel over a posted bridge, this increases its travel time and distance, and therefore costs. …
-
An evaluation of alternative analysis methods for production load rating of culverts
… models for culverts will produce more reliable load ratings. In this thesis, reliability means the coherence between predicted and observed events. Load-soil-structure interaction was the only portion of reliability investigated. Those aspects of reliability associated with method repeatability, …
-
Using building information modeling to track and assess the structural condition of bridges
… the importance of it. When determining a safe load carrying capacity of a bridge, damage location information is significant because shear and moment limit states are more critical at different locations and member capacities can vary along the length of a span. Capturing damage location …
-
Effect of Transverse Post-Tensioning on Moment Distribution Between Channel Girders
… in South Carolina and how to improve their load distribution. The specimens are 30 feet in length, 33 inches wide and 17 inches deep. South Carolina has 377 bridges containing prestressed concrete channel girders and many of these bridges received a poor load rating in a recent load rating …
-
Load Rating Evaluation of Deteriorated Prestressed Channel Girders
… (SCDOT) is conducting a multi-year effort to load rate its inventory of over 9,400 bridges. This includes many bridges that are load posted due to potential structural considerations (e.g., outdated design loads, members whose capacity is difficult to assess, structural degradation). The …
-
Impact of Truck Platooning on Texas Bridges
… each of these structures estimated truck platoon load ratings were calculated according to the original design methodology (allowable stress, load factor, or load and resistance factor) using NBI data elements along with assumptions from prior studies. The obtained load ratings from the older …
-
A strength and serviceability assessment of high performance steel Bridge 10462
… was assessed by conducting static and dynamic load tests. The Culloden Bridge is a three-span-continuous bridge that utilizes HPS 100W in the compression flanges of sections in negative flexure at interior supports. The experimental natural frequency, lateral live load distribution factors, and …
-
Diagnostic testing for improved load rating of reinforced concrete slab bridges
… were designed for less than the current legal load, they are still in service and performing adequately. Currently the bridges in Texas are load rated based on a procedure similar to the original design procedure. These procedures are very conservative and result in low load ratings for slab …
-
Methods to develop composite action in non-composite bridge floor systems: part I
… deficient, with about 3500 bridges posted for load, meaning that they do not meet today’s design load ratings. More than one out of every eight bridges is proposed to be replaced, at a cost of $15 billion, because of insufficient capacity or roadway geometry. Economic methods of rehabilitating …
-
Bridge Load Rating Utilizing Experimental Data and Finite Element Modeling
… Highway Administration, 2011) Accurate bridge load rating can potentially reduce, and even remove, bridge postings throughout the state. Analytical structural bridge models were used to define new load ratings for ALDOT Bridges 005248, 005318, and 012296. With past methodology, Engineers' …
-
Live Load Test and Finite Element Model Analysis of a Box Girder Bridge for the Long Term Bridge Performance Program
… due to environmental variables and vehicle loads. Part of this program includes the periodic testing of selected bridges. The Lambert Road Bridge was subjected to nondestructive testing in the fall of 2009. Part of this testing included a live load test. This test involved driving two heavy …
-
Live-Load Testing and Finite-Element Analysis of a Steel Cantilevered Deck Arched Pratt Truss Bridge for the Long-Term Bridge Performance Program
… as the bridge underwent non-destructive live loading. The recorded gauge readings were analyzed to determine bridge behavior and then used in the assistance of calibrating a working finite-element model. After a working model was verified the distribution factors for the interior and exterior …
-
Evaluation of bridge rating methods
… these structures is to perform diagnostic load testing on bridges that are structurally deficient. Frequently, diagnostic load tests reveal strength and serviceability characteristics that exceed the predicted codified parameters. Usually, the codified parameters are conservative when …
-
Load rating analysis, field testing of steel railroad bridges - dailey branch bridges at mileposts 1.4 and 5.8
… 17.875 feet. These bridges are evaluated for the load ratings using AREMA 2014 manual using the allowable stress method. Since, the material properties of the bridge members are definitely unknown, the yield strength of steel assumed is in accordance with the instructions in AREMA 2014 manual. The …
-
Development of a Methodology to Load Rate General Aviation Airports with Environmental Considerations
… This research seeks to develop a methodology to load rate GA airports with consideration for facilities located in coastal regions that are at greater risk of experiencing flood events. Procedures are developed to accurately estimate annual airport traffic and pavement structural capacity during …
-
Load Testing Deteriorated Spans of the Hampton Roads Bridge-Tunnel for Load Rating Recommendations
… Virginia coast has taken its toll on the main load carrying girders. Concrete spalling has exposed prestressing strands within the girders allowing corrosion to spread. Some of the more damaged girders have prestressing strands that have completely severed due to the extensive corrosion. The …
-
Consideration of strand fatigue for load rating prestressed concrete bridges
… the strand in prestressed concrete beams for the load rating of prestressed concrete bridges. The criteria for load rating prestressed concrete bridges are provided by the American Association of State Highway and Transportation Officials in the Manual for Condition Evaluation of Bridges, which …
-
The Relationship of Cognitive Load and Different Participant Roles on Knowledge Retention in Simulation-based Learning Among Undergraduate Nursing Students
… High-fidelity simulation (HFS) is a cognitive load inducing educational tool that gives participants an opportunity to emulate clinical scenarios by assuming various roles. HFS offers opportunities for undergraduate nursing students to build fundamental knowledge that can replace, or enhance, …
-
Structural Condition Assessment Of Prestressed Concrete Transit Guideways
… share common design details, geometries, and loading conditions. The original analysis is based on certain simplifying assumptions such as rigid behavior over supports and simplified tendon/concrete/steel plate interaction. The current objective is to conduct a representative study for a more …
Page 1 of 2