Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"Load Shaving"”.

  1. PV Integration and Peak Load Shaving Using Energy Storage Feasibility Study

    … is used in different application such as peak load shaving, system upgrade deferrals, and improving renewable energy integration. A photovoltaic system (PV) is wildly used in the distribution system, and it has given good results in reducing the amount of consumed electrical power from the grid …

    calgary Repository record for PV Integration and Peak Load Shaving Using Energy Storage Feasibility Study (opens in a new tab)

  2. Peak Load Shaving Using Battery Energy Storage Systems for a Regional Distribution Network

    … frequently encounter challenges during peak load periods, including elevated infrastructure costs, grid congestion and instability, higher fuel consumption, environmental pressures, increased transmission and distribution losses, and reduced system efficiency. These issues arise from surges …

    unsw Repository record for Peak Load Shaving Using Battery Energy Storage Systems for a Regional Distribution Network (opens in a new tab)

  3. Peak Load Shaving and Power Quality Improvement for the Louis-Hippolyte-La Fontaine Tunnel in Montréal

    … to adopt Energy Storage Systems (ESS) for peak load shaving. In this thesis, a Battery Energy Storage System (BESS) is sized and controlled to reduce the constraints imposed on the electrical grid by the Louis-Hippolyte-La Fontaine Tunnel by means of peak load shaving. The peak load reduction is …

    concordia Download PDF for Peak Load Shaving and Power Quality Improvement for the Louis-Hippolyte-La Fontaine Tunnel in Montréal (opens in a new tab)

  4. A Case Study on Application of Fuzzy Logic based Controller for Peak Load Shaving in a Typical Household's Per Day Electricity Consumption

    … and distribution of power. The electrical load consumed by consumers per day is not constant throughout the day. The utilities must be capable of meeting the load demand, which means they must have enough electricity generation potential and necessary infrastructure. This cost is …

    gvsu Repository record for A Case Study on Application of Fuzzy Logic based Controller for Peak Load Shaving in a Typical Household's Per Day Electricity Consumption (opens in a new tab)

  5. Optimization of electricity consumption using thermal and battery energy storage systems in smart buildings

    … and release it in peak hours to achieve peak load shaving, save cost, provide the demand load, and increase the power quality and stability. However, based on the limited capacity of ESSs and their limitations, it is challenging to meet peak load shaving criteria determined by utility …

    ets-quebec Download PDF for Optimization of electricity consumption using thermal and battery energy storage systems in smart buildings (opens in a new tab)

  6. Solar Farm Utilizing a Battery Energy Storage System

    … during peak energy demand. This achieves peak load shaving which reduces the cost of electricity for the customer and is ecologically friendly. This thesis aims to create an efficient solar farm with a battery energy storage system for a farmer in California that achieves peak load shaving. …

    calpoly Repository record for Solar Farm Utilizing a Battery Energy Storage System (opens in a new tab)

  7. Power system transmission enhancement through storage

    … on single storage system is compared with Load Shaving method, which indicate that three methods have approximately the same storage schedule and daily fuel cost. Results on two storage system with QP method suggest that the coordination between storage units can help to transfer more power …

    vt Repository record for Power system transmission enhancement through storage (opens in a new tab)

  8. Integration of passive and active phase change storage systems into buildings

    … The results identified considerable peak-load shaving and improved thermal comfort. The outcomes are being used in the development of commercial products for integration into new buildings and retrofitting into existing ones.

    adelaide Repository record for Integration of passive and active phase change storage systems into buildings (opens in a new tab)

  9. Application of Supercapacitor in Elecrical Energy Storage

    … with the supercapacitor to achieve peak load shaving as well as Uninterruptible Power Supply (UPS) functionalities. Due to the need to operate in both buck-boost and boost modes, a tri-state hybrid mode was proposed to bridge the buck-boost and boost modes. It was proven experimentally …

    nus Repository record for Application of Supercapacitor in Elecrical Energy Storage (opens in a new tab) Download file for Application of Supercapacitor in Elecrical Energy Storage (opens in a new tab)

  10. Planning and operation of active smart grids

    … also become a viable solution for balancing the load and the intermittent generation of renewable energy sources. The DSS can also provide the smart grid operator with various other benefi ts including peak load shaving, resilience enhancement, power loss reduction, and arbitrage gain. The active …

    ubc Repository record for Planning and operation of active smart grids (opens in a new tab) Download PDF for Planning and operation of active smart grids (opens in a new tab)

  11. Optimization of Residential Battery Energy Storage System Scheduling for Cost and Emissions Reductions

    … bills by using energy storage systems for load shifting and/or peak load shaving. While there are numerous system designs and model formulations for minimizing electric bills under these rate structures the use of these systems has the potential to cause an increase in emissions from the …

    rit Repository record for Optimization of Residential Battery Energy Storage System Scheduling for Cost and Emissions Reductions (opens in a new tab)

  12. Batteries and thermal energy storage: an analytical method for sizing and analyzing potential synergies in hybrid systems

    … generation capacity is sized to meet the peak load, typically in the summer when building cooling loads are high and is underutilized for much of the year. Electric utilities often pass on the costs associated with these peaking generators to building owners through demand charges. Building …

    colo-mines Repository record for Batteries and thermal energy storage: an analytical method for sizing and analyzing potential synergies in hybrid systems (opens in a new tab)

  13. Microgrid Modeling and Grid Interconnection Studies

    … converter is designed in a way to function for load-shaving during unplanned load changes in the microgrid. This fully functioning microgrid is then connected with the main grid using Kundur’s two-area system and simulated for various faults and load changes. A collection of data at the point of …

    ut-knoxville Repository record for Microgrid Modeling and Grid Interconnection Studies (opens in a new tab)

  14. Implementing Utility-Scale Battery Energy Storage with Renewable Generation Under Abnormal System Conditions

    … generation, frequency and voltage support, peak load shaving and demand-side management. The following parameters of battery energy storage should be monitored, recorded and controlled to be used efficiently in this context of available energy capacity, power quality, Volt-Watt support, Volt-Var …

    buffalo Repository record for Implementing Utility-Scale Battery Energy Storage with Renewable Generation Under Abnormal System Conditions (opens in a new tab)

  15. Dynamic dispatch of direct load control

    Direct Load Control (DLC) -- the direct control of customer loads by an electric utility for the economic and reliable operation of the power system, is an important and active element of Load Management (LM). Currently attention has focussed on the integration of DLC into system operations. …

    vt Repository record for Dynamic dispatch of direct load control (opens in a new tab)

  16. Distribution circuit multi-time-scale simulation tool for wind turbine and photovoltaic integration analysis

    … variability of wind speed, solar irradiance, and load consumption, determining the maximum penetration of wind turbines and PVs, and sizing of energy storage for peak load shaving and power variability control. The proposed multi-time-scale simulation tool developed in MATLAB includes several …

    texas Repository record for Distribution circuit multi-time-scale simulation tool for wind turbine and photovoltaic integration analysis (opens in a new tab)

  17. Design and Operation of Stationary Distributed Battery Micro-storage Systems

    … Moreover, energy storage allows for leveling the load, shaving peak demands, and furthermore, transacting power with the utility grid. This research proposes an energy management system (EMS) to manage the operation of distributed grid-tied battery micro-storage systems for stationary applications …

    ucf Repository record for Design and Operation of Stationary Distributed Battery Micro-storage Systems (opens in a new tab)

Page 1 of 2