Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 68 for “"Load Transient"”

  1. Shipboard fault detection, load transient exploration, and power simulation

    Non-intrusive load monitoring experiments have provided useful information in practice for activity tracking, condition-based maintenance, energy scorekeeping, and fault detection through various installations over several decades. Changes in power transient behavior on electrical loads are …

    mit Repository record for Shipboard fault detection, load transient exploration, and power simulation (opens in a new tab)

  2. Fast load transient response and chip area efficient low dropout regulators

    … power management applications.</p> <p>First, a load-transient-enhanced and chip-area-efficient LDR based on a wide-swing voltage buffer without using on-chip compensation capacitor and large equivalent series resistance (ESR) for compensation is proposed. The small parasitic capacitor of the …

    hkust Repository record for Fast load transient response and chip area efficient low dropout regulators (opens in a new tab)

  3. Simulation of synchronous machine model and analysis of fault and load transient

    … generator that supplies a three phase active load through a three-phase diode rectifier with AC excitation as the primary mean of excitation. The model is subjected to different fault and load situations for the study of transient dynamics. The design and simulation was carried out in MATLAB …

    nanyang Repository record for Simulation of synchronous machine model and analysis of fault and load transient (opens in a new tab)

  4. Digitally Controlled DC-DC Converters with Fast and Smooth Load Transient Response

    … power supplies (SMPS) used for point-of-load (PoL) applications need to meet increasingly stringent requirements on voltage regulation, while minimizing physical volume and optimizing conversion efficiency. The focus of this thesis is the voltage regulation capability of low-power PoL …

    toronto-retro Repository record for Digitally Controlled DC-DC Converters with Fast and Smooth Load Transient Response (opens in a new tab)

  5. Integrated design of DC-DC power converters target for fast load transient applications

    … (PWM) control method at heavy load condition and shifts to Pulse-Frequency-Modulation(PFM) control at light load condition. This hybrid dual mode operation can indeed improve the efficiency over a wide loading range. However, dual mode operation also implies more complicated …

    nanyang Repository record for Integrated design of DC-DC power converters target for fast load transient applications (opens in a new tab)

  6. Design of buck converter with fast load transient response based on time domain analysis

    <p>Fast-load transient response DC-DC power converters are currently in great demand for portable electronic devices. Conventional control methodologies such as voltage-mode and current-mode scheme cannot achieve fast-load transient response due to the large compensation capacitor existing in the …

    hkust Repository record for Design of buck converter with fast load transient response based on time domain analysis (opens in a new tab)

  7. PEAK SHAVING AND LOAD TRANSIENT RESPONSE MITIGATION WITH HYBRID ALTERNATING AND DIRECT CURRENT MICROGRIDS

    … energy. This work evaluates peak shaving and transient load management in a COTS hybrid microgrid using a hybrid energy storage system (HESS) of lead-carbon batteries and a supercapacitor. Physics-based modeling and simulations informed the control strategy and predicted system dynamics under …

    nps Repository record for PEAK SHAVING AND LOAD TRANSIENT RESPONSE MITIGATION WITH HYBRID ALTERNATING AND DIRECT CURRENT MICROGRIDS (opens in a new tab)

  8. Current-mode DC-DC buck converter with current-voltage feedforward control

    … systems must have fast dynamic response to both load transient- and reference- tracking. Dynamic response of conventional voltage-mode and current-mode switching converters are limited in load transient. V<sup>2</sup> control has been proposed and is able to achieve fast load transient response. …

    hkust Repository record for Current-mode DC-DC buck converter with current-voltage feedforward control (opens in a new tab)

  9. High frequency high efficiency high dynamic range (3H) DC-DC converter IC

    … urgent to develop a voltage regulator with fast load transient response and large current delivery capability to power the next generation microprocessor. The scope of this thesis is to design a dc-dc converter which delivers large current and responses fast to the load transient without …

    nanyang Repository record for High frequency high efficiency high dynamic range (3H) DC-DC converter IC (opens in a new tab)

  10. High Performance Digital Control Techniques for Powering Microprocessors

    … adjustment, non-linear control and a dedicated transient detection circuit is proposed to improve the dynamic performance. The dynamic reference step adjustment method lowers the high speed requirement of reference update clock; the non-linear control minimizes the transient-assertion-to-action …

    queens Repository record for High Performance Digital Control Techniques for Powering Microprocessors (opens in a new tab)

  11. NOVEL CONTROL APPROACHES TO IMPROVE SINGLE AND MODULAR DC-DC CONVERTERS DYNAMICS IN DATA CENTERS

    … there are specific requirements such as fast load dynamics and sensitive power, voltage or current sharing. Therefore, power converters need to provide and maintain ultra fast responses to achieve a certain control objective. For example, for voltage regulators connected to the points of the …

    alberta Repository record for NOVEL CONTROL APPROACHES TO IMPROVE SINGLE AND MODULAR DC-DC CONVERTERS DYNAMICS IN DATA CENTERS (opens in a new tab)

  12. Entire Load Efficiency And Dynamic Performance Improvements For Dc-dc Converters

    … efficiency for On-Board Converters or Point of load (POL) converters, the second aspect is load adaptive control techniques to improve all load efficiency for battery powered DC-DC converters that are applied to mobile devices, and the third aspect is dynamic performance improvement techniques …

    ucf Repository record for Entire Load Efficiency And Dynamic Performance Improvements For Dc-dc Converters (opens in a new tab)

  13. Analysis and design of a highly efficient and versatile DC-DC converter

    … the advantages of simple structure, good light load efficiency and fast response to load step. The purpose of this research is to develop AOT control in two areas: digital control for its process scalability and flexibility, and ultra-low-power operation. Novel circuit blocks and techniques have …

    nanyang Repository record for Analysis and design of a highly efficient and versatile DC-DC converter (opens in a new tab)

  14. Design of monolithic power converters with fast reference-tracking

    … behaviors between reference-tracking and load transient are clarified. Common fix-frequency control schemes including voltage-mode control, current-mode control and V<sup>2</sup>-control are studied and the latter is found to be inherently slow in reference-tracking.</p><p>Feed-forward …

    hkust Repository record for Design of monolithic power converters with fast reference-tracking (opens in a new tab)

  15. A Fast Response Dual Mode Buck Converter with Automatic Mode Transition

    … improve the efficiency over a wide range of the load current. Due to the highly varying nature of the load, it is beneficial to have the converter switch between the modes without an external mode select signal. This work proposes a new technique for automatic mode switching which maintains very …

    tamu Repository record for A Fast Response Dual Mode Buck Converter with Automatic Mode Transition (opens in a new tab)

  16. State-Trajectory Analysis and Control of LLC Resonant Converters

    … tank. In some highly dynamic processes like the load transient, start-up, over-load protection and burst operation, it is hard to control the current and voltage stresses and oscillations in the resonant tank. Moreover, to meet the high power density requirement, the LLC is required to operate at …

    vt Repository record for State-Trajectory Analysis and Control of LLC Resonant Converters (opens in a new tab)

  17. Microcontroller (MCU) Based Simplified Optimal Trajectory Control (SOTC) for High-Frequency LLC Resonant Converters

    … unpredictable dynamics, burst mode for light-load efficiency, soft start-up and short circuit protection. Additionally, digital controllers are gradually taking the place of analog controllers in the control of the LLC resonant converter due to the advantages of the digital controllers over …

    vt Repository record for Microcontroller (MCU) Based Simplified Optimal Trajectory Control (SOTC) for High-Frequency LLC Resonant Converters (opens in a new tab)

  18. Analysis, design, and implementation of digital dc-dc converters

    … controller, and a window SAR ADC to achieve fast transient response and low overshoot. An additional predictive or jerk component is introduced to the conventional PID controller to speed up the transient response and reduce the settling time by 50%. In addition, a feedforward control is also …

    nanyang Repository record for Analysis, design, and implementation of digital dc-dc converters (opens in a new tab)

  19. Wide input range DC-DC converter with digital control scheme

    … exhibits 2:1 voltage variation as well as a slow transient response. The proposed approach consists of two stages: a primary three-level boost converter stage cascaded with a high frequency, isolated boost converter topology, which provides a higher voltage gain and isolation from the input …

    tamu Repository record for Wide input range DC-DC converter with digital control scheme (opens in a new tab)

  20. Design and realization of low dropout voltage regulators in PMIC for portable applications

    … Amongst all the design metrics of LDO, a fast load transient response with small overshoot/undershoot is arguabely the most important yet challenging specification for LDO to achieve. This is mainly due to two reasons. Firstly, modern mobile SoC is becoming more and more complex with higher …

    nanyang Repository record for Design and realization of low dropout voltage regulators in PMIC for portable applications (opens in a new tab)

Page 1 of 4