Results 1 to 20 of 21 for “"Locking Screws"”
-
Dynamisierung der Cis-Kortex durch Einsatz von "Dynamic Locking Screws" in einer mit "Locking compression plates" fixierten Tibiaquerosteotomie: eine experimentelle Studie an Schafen
… this study was to evaluate two types of dynamic locking screws in comparison to the standard bicortical locking head screw (LS). One of the dynamic screws was developed and produced by Synthes® Switzerland (dynamic locking screw, DLS), the other one was produced to match the far cortical locking …
-
Humeral Fracture Fixation Techniques: A FEA comparison of locing and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws.
Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct …
-
Biomechanical Evaluation Of Locked and Non-locked Constructs Under Axial And Torsion Loading
Locking compression plates are proven to be safe for use in open reduction and internal fixation (ORIF). The ORIF is a procedure performed to treat fractures. It has various combination of holes, the system provides more options for clinicians to use either locking screw or non-locking screws. This …
-
Neurovascular structures at risk from proximal locking of retrograde femoral nails
… insertion of both proximal and distal interlocking screws for maximal axial and rotational stability. The distal screws are inserted lateral to medial in a relatively safe area of the lower thigh using an external guide. The proximal locking screws by contrast are inserted 'freehand' at the …
-
Novel biomechanical test method for cancellous bone screws and screw augmentation with cement.
… loading[17][20][21]. The increased use of locked screws in plate constructs has also changed the loading patterns of bone screws. For this study, a novel “toggle-out” testing method was developed to more realistically simulate in-vivo loading of screw-plate constructs. Our objective was to compare …
-
A Biomechanical Comparison of Locking Compression Plate Constructs with Plugs/Screws in Osteoporotic Bone Model
Locking compression plates are proven to be safe for use in open reduction and internal fixation (ORIF) especially in osteoporotic bones. Because of various combinations of holes, the system provides more options for clinicians to use either locking screws or non-locking screws. This clinical …
-
FUNCTIONAL BIOMECHANICAL EVALUATION OF MULTIPLE DESIGN PROGRESSIONS OF DISTAL RADIUS VOLAR PLATES
… normal wrist function. Volar plate fixation with locking screws has become increasingly popular among surgeons for the treatment of unstable distal radius fractures. The purpose of the present study was to evaluate the biomechanical performance of different design progressions of the volar plating …
-
Η ανάπτυξη και μελέτη ( κλινική και εμβιομηχανική) ενός νέου ενδομυελικού ήλου για την αντιμετώπιση των καταγμάτων της διάφυσης του βραχιονίου
… is provided without the need for distal locking screws in the majority of fractures, while the need for proximal locking screws during the antegrade procedure is abolished. The nail has been tested for both its biomechanical properties and its clinical usefulness in a series of patients …
-
Die Dynamisierung der winkelstabilen Plattenosteosynthese mit Hilfe der Dynamic Locking Screw (DLS) : ein experimentelle Studie an Schafen
… von 0, 1 oder 3 mm Breite wurde mit einer Locking-Compression-Plate in Kombination mit den zu evaluierenden Dynamischen Kopfverrieglungsschrauben (DLS) refixiert. Der Heilungsverlauf wurde radiologisch in einem dreiwöchigen Rhythmus über sechs, beziehungsweise zwölf Wochen kontrolliert. Am …
-
Mechanical Comparison of a Type II External Skeletal Fixator and Locking Compression Plate in a Fracture Gap Model
… II external skeletal fixator (ESF) to a 3.5 mm locking compression plate (LCP) in axial compression, mediolateral, and craniocaudal bending in a fracture gap model. The hypothesis was that the Type II ESF would demonstrate comparable stiffness to the LCP. A bone simulant consisting of short …
-
Development and Validation of a Single-Camera Video Extensometer
… distal radius models, repaired using either locking or non-locking screws, were tested through a simulated healing and rehabilitation period. Changes with respect to failure criteria were measured using calipers and the video extensometer. Similar trends were found between video and caliper …
-
A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model
… To compare the biomechanical properties of 3.5 locking compression plate (LCP) fixation to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model in static axial compression and cyclic axial compression and torsion. Study …
-
Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty
… anterior-posterior peripheral screw type (nonlocking vs. locking), and bone density (10 vs. 25 pcf). Samples were cyclically loaded under compression and shear with a 500 N force at 60° to simulate peak loads during shoulder abduction. Implant-bone motion was measured using four linear …
-
Ein neues System zur periprothetischen Frakturstabilisierung
… Especially in Vancouver type B1 fracture locking plate systems provide a soft tissue preserving and safe technique. Therefore it is necessary to advance and test new implants. Aim: This study compares the hinge system of the distal lateral femur plate (LOQTEQ®) with locking attachment …
-
Μελέτη των οστεοτομιών του 1ου μετατάρσιου στη χειρουργική θεραπεία του βλαισού μεγάλου δακτύλου του ποδιού
… had no statistical difference. When plates with locking screws were introduced in proximal osteotomies, complications were minimized compared to K-w fixation and the technique was easier.
-
Implant-Supported Prosthesis in Fibula Free Flap Jaw-in-a-Day Reconstruction Using Finite Element Analysis
… concentrated within the fixation plates and locking screws rather than at fibula-mandible or fibula-fibula junctions. The Superior-Immediate configuration produced the highest stresses (131 MPa at the right screw hole and 134 MPa at the right graft-mandible junction) and the greatest …
-
Εκτίμηση της σταθερότητας της κεντρικής ασφάλισης του ενδομυελικού ήλου στα κατάγματα του άνω τριτημορίου της κνήμης
… nails in order to accommodate multiple locking screws in various directions. The objective of the present biomechanical study is to compare the stability of six tibial nails when they are used for the treatment of unstable, extra-articular, proximal tibial fractures. Thirty composite …
-
Ενδομυελική ήλωση μακρών οστών με τον ήλο S2: προοπτική μελέτη για τις ιδιαιτερότητες και τα πλεονεκτήματα που αφορούν στην περιφερική ασφάλιση
… been studied extensively but the part of distal locking of intramedullary nails continues to be troubleshooting for many Surgeons. “Free-hand” technique is excessively used as a targeting method for distal locking despite the fact that it is a time-consuming process, frequently traumatic and …
-
Treatment of distal radius fractures with volar locking distal radius plates
… However, with the development of volar locking distal radius plates in 1997, considerable scientific, clinical and commercial interest in the treatment of distal radius fractures by open reduction and plate fixation has developed. The plates do have theoretical advances over other means …
-
Biomechanical Evaluation of Hybrid Locked Plating for Humeral Shaft Fracture Fixation
<p>Bone plate and screws are commonly used for fixation of humeral shaft fractures.A hybrid construct with unlocked screws and locked screws has gained popularity forfixation of comminuted fractures. Unlocked screws are used to reduce fracture gap while locked screws with better fixation strength …
Page 1 of 2