Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"Locking plate"”.

  1. Optimisation of locking plate fixation methods for periprosthetic fractures

    … bone and an unstable prosthesis. Failure of locking plate fixation of fractures around the tip of a stable prosthesis (Vancouver type B1) have been reported clinically, suggesting that further investigation into their treatment is needed. This study developed a computational periprosthetic …

    whiterose Download PDF for Optimisation of locking plate fixation methods for periprosthetic fractures (opens in a new tab)

  2. Simulation-based design of patient-specific femoral locking plate using topology optimization

    Femoral locking plates are orthopedic implants used in closed reduction of the fractured femur. These orthopedic implants designed using conventional methods apply finite element analysis to evaluate their performance. These traditional approaches result in failure of implants and need for revision …

    missouri Repository record for Simulation-based design of patient-specific femoral locking plate using topology optimization (opens in a new tab)

  3. The Advanced Locking Plate System (ALPS): application and results in 71 small animal patients

    … the results of application of the advanced locking plate system (ALPS) in small animal surgery. Study Design – Case series. Animals – Client-owner dogs and cats (n=71) that were treated with ALPS (n= 72). Methods – Animals treated with ALPS (2007-2010) were evaluated. Data included …

    zurich

  4. Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures

    … The aim of study was to compare four designs of locking plates at biomechanical characteristics for the stabilization of experimentally induced comminuted tibial fractures in dog. Material and Methods: Pelvic limbs were harvested from sixteen dog cadavers. Paired tibiae were stripped of all soft …

    brazil-ufv Repository record for Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures (opens in a new tab)

  5. Comparison of a novel surgical implant with the volar locking plate for the treatment of distal radius fractures: a mechanical study

    … non-operative approach to surgery, using volar locking plate (VLP) technology. Surgery, however, is not without risk, complications including failure to restore an anatomic reduction, fracture re-displacement (loss of reduction), and tendon rupture. The objectives of this study were to optimize …

    sask Repository record for Comparison of a novel surgical implant with the volar locking plate for the treatment of distal radius fractures: a mechanical study (opens in a new tab)

  6. Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate

    … investigating the appropriateness of the 1.5mm locking compression plate (LCP) for repair of radial and ulnar fractures in miniature breed dogs. A retrospective study will review the current use and results of the mini-cuttable plates in miniature breeds while a biomechanical study compares the …

    guelph Repository record for Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate (opens in a new tab)

  7. Τροποποιημένη διαφυσική οστεοτομία 1ου μεταταρσίου Ludloff στην αντιμετώπιση του βλαισού μέγα δακτύλου: εμβιομηχανική και κλινική μελέτη

    … fixation of Ludloff osteotomy by addind a small locking plate on the medial site. Twenty identical fourth generation synthetic 1st metatarsals (Sawbone, Pacific Research Laporatories, Vashon, WA) were used for biomechanical comparisons.The specimens were divided into two groups. The first-A Group …

    greece Repository record for Τροποποιημένη διαφυσική οστεοτομία 1ου μεταταρσίου Ludloff στην αντιμετώπιση του βλαισού μέγα δακτύλου: εμβιομηχανική και κλινική μελέτη (opens in a new tab)

  8. Šlaunikaulių periprotezinių lūžių problematika. Klinikinis atvejis /

    … open reduction and internal fixation with a locking plate, implantation of custom cement and metal structures and distal femoral replacement. Demographic changes are leading to a ever-increasing number of older patients with arthrosis, while the improving availability of health care services …

    vilnius Repository record for Šlaunikaulių periprotezinių lūžių problematika. Klinikinis atvejis / (opens in a new tab)

  9. Investigation of fixation of the disrupted pubic symphysis using multiple prosthetics in cadaveric models

    … symphysis in order to determine whether the locking plate was able to limit the motion per force better than the compression plate. The displacement data and the compliance coefficient data provided evidence that the locking plate assembly is more apt to limit motion in the pubic symphysis. …

    ttu Repository record for Investigation of fixation of the disrupted pubic symphysis using multiple prosthetics in cadaveric models (opens in a new tab)

  10. Translational Models for Advancement of Regenerative Medicine and Tissue Engineering

    … segmental tibial defect stabilized using single locking plate fixation. First, the biomechanical stability of the model was evaluated in vivo using plantar-pressure analysis of gait. Then, the surgical technique was refined through a retrospective analysis of the effects of plate length and …

    utk-theses Repository record for Translational Models for Advancement of Regenerative Medicine and Tissue Engineering (opens in a new tab)

  11. Locking plates for distal femur fractures does an increased working length improve healing?

    Distal femur locking plates have become a very popular means of internal fixation because of their ability to provide stable distal periarticular fixation. In spite of this enthusiasm however several studies have reported significant problems with healing. In the distal femur it is recognized that …

    cape-town Repository record for Locking plates for distal femur fractures does an increased working length improve healing? (opens in a new tab)

  12. Development of a novel endoprosthesis for canine limb-sparing using a finite element approach

    … to those observed clinically. The use of a locking plate in place of the current non-locking plate was also investigated. Several stress redistribution strategies were also examined. A novel modular design was developed in collaboration with the Colorado State University's Veterinary …

    colostate Repository record for Development of a novel endoprosthesis for canine limb-sparing using a finite element approach (opens in a new tab)

  13. Humeral Fracture Fixation Techniques: A FEA comparison of locing and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws.

    Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct …

    maryland Repository record for Humeral Fracture Fixation Techniques: A FEA comparison of locing and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws. (opens in a new tab)

  14. Λοξή διαφυσιακή οστεοτομία 1ου μεταταρσίου (Ludloff) για την διόρθωση βλαισού μεγάλου δακτύλου: συγκριτική εμβιομηχανική μελέτη δύο τύπων

    … site. We suggest the use of a medial mini locking plate as a supplementary fixation. Our clinical outcomes were quite satisfactorily. There was no loss of correction or periosteal bone formation. To test the hypothesis that supplementary use of the medial mini locking plate would improve …

    greece Repository record for Λοξή διαφυσιακή οστεοτομία 1ου μεταταρσίου (Ludloff) για την διόρθωση βλαισού μεγάλου δακτύλου: συγκριτική εμβιομηχανική μελέτη δύο τύπων (opens in a new tab)

  15. A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants

    … shaft fractures: intramedullary nailing and locking plate systems. Comparison of finite element results -- from simulated physiological loading conditions and loads induced by "virtual surgery" -- among the optimized implants and those currently used in the operating room showed much …

    missouri Repository record for A comprehensive simulation-based methodology for the design and optimization of orthopaedic internal fixation implants (opens in a new tab)

  16. A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model

    … with either a 6-hole Dynamic Compression Plate applied in compression or a 6-hole Locking Compression Plate. Pelves were tested in cantilever bending to failure and construct stiffness, yield load, ultimate load at failure, displacement at failure, and mode of failure compared. The mean …

    guelph Repository record for A Comparison of Dynamic Compression Plates and Locking Compression Plates Using Cantilever Bending in a Canine Ilial Fracture Model (opens in a new tab)

  17. Finite Element Representation of Bone-Screw Mechanics

    … directly on the shoulder or arm. Fixation using locking plates and bone screws has become the treatment of choice; however, an overall complication rate of 49% has been reported, with 7.5% resulted from failure of the bone-screw interface. Accordingly, the purpose of the work presented in this …

    denver Repository record for Finite Element Representation of Bone-Screw Mechanics (opens in a new tab)

  18. Fracture fixation of complex tibial plateau fractures

    Bi-condylar tibial plateau fractures with the highest frequency in 40-to-60-year-old patients accounts for 35% of all tibial plateau fractures. Surgical treatment of this fracture remains challenging due to the multi-planar articular comminution and the subsequent severe soft tissue injuries. …

    lmu-germany Repository record for Fracture fixation of complex tibial plateau fractures (opens in a new tab)

  19. A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model

    … To compare the biomechanical properties of 3.5 locking compression plate (LCP) fixation to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model in static axial compression and cyclic axial compression and torsion. Study …

    vt Repository record for A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model (opens in a new tab)

Page 1 of 2