Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"Locking plates"”.
-
The Biomechanics of Locking Plates used in a Supercutaneous Fashion
… leading to the investigation of alternatives. Locking plates, such as the string of pearls (SOP) and locking compression plate (LCP), gain strength from the screw-plate interface. Although soft tissue disruption is required for placement on the bone, precise contouring is not necessary. The …
-
Locking plates for distal femur fractures does an increased working length improve healing?
Distal femur locking plates have become a very popular means of internal fixation because of their ability to provide stable distal periarticular fixation. In spite of this enthusiasm however several studies have reported significant problems with healing. In the distal femur it is recognized that …
-
Treatment of distal radius fractures with volar locking distal radius plates
… fixation was not a popular treatment option as plates inserted from the dorsal side frequently caused soft tissue complications and plates inserted from the volar side needed additional augmentation as a result of the biomechanical specifics of distal radius fractures. However, with the …
-
Ex vivo biomechanical comparison of reinforced locking plate design and locking compression plates applied in comminuted tibial fractures
… The aim of study was to compare four designs of locking plates at biomechanical characteristics for the stabilization of experimentally induced comminuted tibial fractures in dog. Material and Methods: Pelvic limbs were harvested from sixteen dog cadavers. Paired tibiae were stripped of all soft …
-
A Biomechanical Comparison of 3.5 Locking Compression Plate Fixation to 3.5 Limited Contact Dynamic Compression Plate Fixation in a Canine Cadaveric Distal Humeral Metaphyseal Gap Model
… To compare the biomechanical properties of 3.5 locking compression plate (LCP) fixation to 3.5 limited contact dynamic compression plate (LC-DCP) fixation in a canine cadaveric, distal humeral metaphyseal gap model in static axial compression and cyclic axial compression and torsion. Study …
-
Simulation-based design of patient-specific femoral locking plate using topology optimization
Femoral locking plates are orthopedic implants used in closed reduction of the fractured femur. These orthopedic implants designed using conventional methods apply finite element analysis to evaluate their performance. These traditional approaches result in failure of implants and need for revision …
-
Reconstruction of distal femoral fractures with fixed-angled or polyaxial technology; a prospective randomised controlled trial.
… demands on the surgeon and the selected implant. Locking osteosynthesis devices have been shown to provide superior stability to axial loading compared with traditional, unlocked osteosynthesis plate-screw constructs, blade plates and intra-medullary nails.. However, the outcome following fixation …
-
Validation of a feline femoral bone surrogate with mechanical and clinical evaluation of feline orthopedic implants
… the mechanical behavior of two novel feline interlocking nails against plate controls in vitro, in an attempt to evaluate their safety and efficacy. Following testing in both torsion and 4-point bending, the I-Loc nail was evaluated in 30 clinical feline trauma cases.Fracture gap constructs were …
-
Finite Element Representation of Bone-Screw Mechanics
… directly on the shoulder or arm. Fixation using locking plates and bone screws has become the treatment of choice; however, an overall complication rate of 49% has been reported, with 7.5% resulted from failure of the bone-screw interface. Accordingly, the purpose of the work presented in this …
-
Fracture fixation of complex tibial plateau fractures
… changed the stress distributions within the locking plates and screws. Furthermore, the lateral locking plate cannot adequately stabilize this fracture, and a double plating method including a supplemental medial plate is required. Consequently, it is highly recommended to apply the coronal …
-
Biomechanischer Stabilitätsvergleich zwei- und dreidimensionaler, winkelstablier Miniimplantate für die Osteosynthese von Mittelhandfrakturen
1 Einleitung .1 1.1 Plattenosteosynthese.1 1.1.1 Frakturheilung .1 1.1.2 Geschichte der Plattenosteosynthese .4 1.2 Winkelstabilität .8 1.2.1 Prinzipien winkelstabiler Verbindungen .10 1.3 Anatomie und Biomechanik der Mittelhand .14 1.4 Frakturen der Mittelhand und Finger .17 1.4.1 Epidemiologie …
-
Auswirkung der Schwingstrecke und des Platten-Winkels einer Doppelplatten-Osteosynthese in einem ovinen Tibia-Defektmodell - eine Finite-Elemente-Analyse
… (DPO) with 120° or 40° plate angle with locking plates (3.5 mm LCP) were compared with single-plate osteosynthesis (4.5 mm LCP) with axial loading at 2000 N and torsion at 25 Nm. The models differed by plate length, plate-to-bone distance, number of screws and plate working length. …
-
Biomechanical comparison of the 1.5mm locking compression plate with the 1.5 and 2.0mm mini-cuttable plates & Effect of bone-plate distance on the biomechanical properties of the 1.5mm locking plate
… investigating the appropriateness of the 1.5mm locking compression plate (LCP) for repair of radial and ulnar fractures in miniature breed dogs. A retrospective study will review the current use and results of the mini-cuttable plates in miniature breeds while a biomechanical study compares the …
-
Behandlung von Unterkieferfrakturen mit Osteosyntheseplatten des UniLock-2.0-Systems
In dieser retrospektiven Studie wurden Unterkieferfrakturen mit dem UniLock-2.0-System behandelt. <br>Material und Methode: <br>Von Juli 2001-Mai 2004 werteten wir die Daten von 53 Patienten mit komplizierten Unterkieferfrakturen, welche mit einer oder mehrern Platten versorgt wurden aus. Alle …
-
Συγκριτική εμβιομηχανική μελέτη ενδομυελικής ήλωσης και εσωτερικής οστεοσύνθεσης με κλειδούμενη πλάκα για τα ενδαρθρικά κατάγματα της εγγύς κνημιαίας μετάφυσης
… with those of modern plating (Single Lateral Locking Plate – SLLP) or conventionalplating (Dual Buttress Plating - DBP). The study’s hypothesis is that the novel techniquecombines ideally the characteristics of the 2 other established techniques, which renders itthe most suitable type of …