Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"Long scan"”.
-
Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping
… flow parameters of the cardiovascular system. Long scan times of three-dimensional flow encoded MRI in particular have, however, hampered the acceptance of the method in a clinical routine setting. Furthermore, concerns have recently been raised about the limited accuracy of the technique. The …
-
Advanced Techniques for Cardiovascular Magnetic Resonance Imaging in Cases of Irregular Motion
… breathing can still lead to unacceptably long scan times and scan abortions. Respiratory motion in patients must also be taken into consideration during the ablation procedure to ensure accu¬rate image guidance. Furthermore, arrhythmia leads to pathological changes in the electrical …
-
High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry
… to ionizing radiation. However, MRI requires long scan times to achieve 3D images at sufficient resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). These long scan times can make subject motion a problem. This thesis describes my work to reduce scan time while achieving …
-
XPS and Carbon-13 NMR spectroscopic analysis of composite rocket propellants
… in the order pendant>>cis>trans. Due to the long scan times involved this method is of limited utility for ageing analysis.
-
Image quality impact of randomized sampling trajectories in MRI: Implications for compressed sensing
… soft tissue contrast but it is limited by long scan times. Compressed sensing (CS) is a novel technique that leverages the underlying transform sparsity of medical images, randomized under-sampling of k-space, and nonlinear reconstruction to recover images from accelerated scans. However, …
-
Multi-parametric mapping using Magnetic Resonance Fingerprinting for cardiac and liver tissue characterization
… However, quantitative MRI suffers from longer scan times than qualitative imaging. Cardiac and liver MR examinations are often difficult to carry out successfully for some patient cohorts (pediatrics, elderly and very ill patients) due to these long scan times and the high number of …
-
Learning-Based Optimization of the Under-Sampling Pattern in MRI
The long scan times of Magnetic Resonance Imaging (MRI) create a bottleneck in patient care and acquisitions can be accelerated by under-sampling in k-space (i.e., the Fourier domain). In this thesis, we focus on the optimization of the sub-sampling pattern with a data-driven framework. Since the …
-
Motion -Compensated 3-D Generalized Series Imaging
… and signal-to-noise efficiency. Unfortunately, long scan times have traditionally precluded the use of 3-D imaging in applications where simultaneous resolution of both small spatial structures and closely spaced temporal events is important. The research in this thesis is aimed at exploiting …
-
Advancement of 31P Magnetic Resonance Spectroscopy Using GRAPPA Reconstruction on a 3D Volume
… for 31P MRSI are patient discomfort due to long scan times and prone positioning within the scanner, as well as reduced data quality due to patient motion and respiration. To further advance the full potential of 31P MRSI as a clinical diagnostic tool in the management of liver cancer, this …
-
Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System
… multi‐point velocity encoding schemes. However, long scan times are currently the main barrier for the acceptance of the method in a clinical setting. The following work presents data‐driven MRI reconstruction algorithms for undersampled measurements with the focus on accurate flow quantification …
-
The design and testing of a novel compact real-time hybrid Compton and neutron scattering instrument.
… imaging systems suffer with limited portability, long scan times, and cover limited energy ranges. Conversely, the imaging system designed, built and tested in this work is not only capable of locating both gamma rays and neutrons, but is also capable of operating in near real time, covers a large …
-
Motion Correction for Dynamic PET/MR Datasets
… activities. Dynamic PET acquisition requires a long scan time, and movement of the subject during this time cannot be fully avoided. Motion of organs due to breathing, heartbeat, etc. is continuous, but there are also bulk motions of body regions to consider which may occur if the subject has …
-
Accelerated J-resolved proton magnetic resonance spectroscopic imaging
1H-MRSI has long been recognized as a powerful tool for noninvasive mapping of metabolites and neurotransmitters. A fundamental challenge of conventional 1H-MRSI is that resonances from different molecules overlap with one another in the crowded chemical shift frequency spectrum, which will lead to …
-
Exploring the Usage of U-Net-based Deep Learning Networks for Reduction of Brain PET Scan Time in Alzheimer's Disease Patients
… biological processes. A high-quality PET scan requires a high dosage of such tracers and/or a long scan time in a PET machine, both of which can be sources of discomfort for the patient. In this work, a potential solution based on deep learning is explored, such that PET scans obtained …
-
Acquisition and reconstruction methods for hybrid 2D/3D diffusion MRI
… 2D diffusion MRI faces many limitations, such as long TR (repetition time) which lead to low SNR (signal-to-noise ratio) efficiency, and long scan times with advanced diffusion protocols which usually require a large number of diffusion directions and/or b values. These limitations become more …
-
Dynamic glucose enhanced chemical exchange saturation transfer MRI : Optimization of methodology and characterization of cerebral transport kinetics
… techniques, sensitivity to motion and long scan durations. Therefore, DGE MRI is not yet ready for clinical implementation, and further evaluation and methodological development are required. The focus of the work presented in this thesis has been on the optimization and development of …
-
Accelerating MRI with Deep Learning: From Anatomic to Quantitative Imaging
… diagnostic quality, resulting in a 10-30 minutes scan time. Such a long scan time might increase motion artifacts and the patient's discomfort. To perform parameter mapping, conventional methods require repeated scans of the same anatomical structure with varying sequence parameters, which limits …
-
Undersampling to accelerate time-resolved MRI velocity measurement of carotid blood flow
… measurement of such information but long scan time limits its clinical application in this area. In order to reduce scan time the MRI signal is often undersampled by skipping part of the signal during data acquisition. The aim of this work is to implement and evaluate different …
-
QUANTITATIVE T2 MAPPING USING ACCELERATED 3D STACK-OF-SPIRAL GRADIENT ECHO READOUT
… data at different echo times, which leads to long scan time. The purpose of this thesis is to develop a rapid and accurate T2 mapping protocol with 3D high-resolution and whole- brain coverage using optimized spiral acquisition, accelerated reconstruction, and model fitting. To implement rapid …
-
Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications
… noise ratio (SNR), incomplete fat suppression or long scan times in some challenging clinical applications, such as MR Neurography, abdominal imaging, whole-body imaging and diffusion-weighted imaging. The research in this thesis aims to improve and develop MR sequences and reconstruction methods …
Page 1 of 3