Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 51 for “"Long scan"”.

  1. Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping

    … flow parameters of the cardiovascular system. Long scan times of three-dimensional flow encoded MRI in particular have, however, hampered the acceptance of the method in a clinical routine setting. Furthermore, concerns have recently been raised about the limited accuracy of the technique. The …

    kings Repository record for Advances in Magnetic Resonance Phase‐Contrast Velocity Mapping (opens in a new tab)

  2. Advanced Techniques for Cardiovascular Magnetic Resonance Imaging in Cases of Irregular Motion

    … breathing can still lead to unacceptably long scan times and scan abortions. Respiratory motion in patients must also be taken into consideration during the ablation procedure to ensure accu¬rate image guidance. Furthermore, arrhythmia leads to pathological changes in the electrical …

    kings Repository record for Advanced Techniques for Cardiovascular Magnetic Resonance Imaging in Cases of Irregular Motion (opens in a new tab) Download PDF for Advanced Techniques for Cardiovascular Magnetic Resonance Imaging in Cases of Irregular Motion (opens in a new tab)

  3. High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry

    … to ionizing radiation. However, MRI requires long scan times to achieve 3D images at sufficient resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). These long scan times can make subject motion a problem. This thesis describes my work to reduce scan time while achieving …

    byu Repository record for High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry (opens in a new tab) Download PDF for High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry (opens in a new tab)

  4. XPS and Carbon-13 NMR spectroscopic analysis of composite rocket propellants

    … in the order pendant>>cis>trans. Due to the long scan times involved this method is of limited utility for ageing analysis.

    vt Repository record for XPS and Carbon-13 NMR spectroscopic analysis of composite rocket propellants (opens in a new tab)

  5. Image quality impact of randomized sampling trajectories in MRI: Implications for compressed sensing

    … soft tissue contrast but it is limited by long scan times. Compressed sensing (CS) is a novel technique that leverages the underlying transform sparsity of medical images, randomized under-sampling of k-space, and nonlinear reconstruction to recover images from accelerated scans. However, …

    calgary Repository record for Image quality impact of randomized sampling trajectories in MRI: Implications for compressed sensing (opens in a new tab)

  6. Multi-parametric mapping using Magnetic Resonance Fingerprinting for cardiac and liver tissue characterization

    … However, quantitative MRI suffers from longer scan times than qualitative imaging. Cardiac and liver MR examinations are often difficult to carry out successfully for some patient cohorts (pediatrics, elderly and very ill patients) due to these long scan times and the high number of …

    kings Repository record for Multi-parametric mapping using Magnetic Resonance Fingerprinting for cardiac and liver tissue characterization (opens in a new tab) Download PDF for Multi-parametric mapping using Magnetic Resonance Fingerprinting for cardiac and liver tissue characterization (opens in a new tab)

  7. Learning-Based Optimization of the Under-Sampling Pattern in MRI

    The long scan times of Magnetic Resonance Imaging (MRI) create a bottleneck in patient care and acquisitions can be accelerated by under-sampling in k-space (i.e., the Fourier domain). In this thesis, we focus on the optimization of the sub-sampling pattern with a data-driven framework. Since the …

    cornell Repository record for Learning-Based Optimization of the Under-Sampling Pattern in MRI (opens in a new tab)

  8. Motion -Compensated 3-D Generalized Series Imaging

    … and signal-to-noise efficiency. Unfortunately, long scan times have traditionally precluded the use of 3-D imaging in applications where simultaneous resolution of both small spatial structures and closely spaced temporal events is important. The research in this thesis is aimed at exploiting …

    uiuc Repository record for Motion -Compensated 3-D Generalized Series Imaging (opens in a new tab)

  9. Advancement of 31P Magnetic Resonance Spectroscopy Using GRAPPA Reconstruction on a 3D Volume

    … for 31P MRSI are patient discomfort due to long scan times and prone positioning within the scanner, as well as reduced data quality due to patient motion and respiration. To further advance the full potential of 31P MRSI as a clinical diagnostic tool in the management of liver cancer, this …

    purdue-thes Repository record for Advancement of 31P Magnetic Resonance Spectroscopy Using GRAPPA Reconstruction on a 3D Volume (opens in a new tab)

  10. Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System

    … multi‐point velocity encoding schemes. However, long scan times are currently the main barrier for the acceptance of the method in a clinical setting. The following work presents data‐driven MRI reconstruction algorithms for undersampled measurements with the focus on accurate flow quantification …

    kings Repository record for Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System (opens in a new tab) Download PDF for Accelerating Multi‐Dimensional Magnetic Resonance Imaging of Blood Flow and Turbulence in the Cardiovascular System (opens in a new tab)

  11. The design and testing of a novel compact real-time hybrid Compton and neutron scattering instrument.

    … imaging systems suffer with limited portability, long scan times, and cover limited energy ranges. Conversely, the imaging system designed, built and tested in this work is not only capable of locating both gamma rays and neutrons, but is also capable of operating in near real time, covers a large …

    lancaster Download PDF for The design and testing of a novel compact real-time hybrid Compton and neutron scattering instrument. (opens in a new tab)

  12. Motion Correction for Dynamic PET/MR Datasets

    … activities. Dynamic PET acquisition requires a long scan time, and movement of the subject during this time cannot be fully avoided. Motion of organs due to breathing, heartbeat, etc. is continuous, but there are also bulk motions of body regions to consider which may occur if the subject has …

    chalmers Repository record for Motion Correction for Dynamic PET/MR Datasets (opens in a new tab)

  13. Accelerated J-resolved proton magnetic resonance spectroscopic imaging

    1H-MRSI has long been recognized as a powerful tool for noninvasive mapping of metabolites and neurotransmitters. A fundamental challenge of conventional 1H-MRSI is that resonances from different molecules overlap with one another in the crowded chemical shift frequency spectrum, which will lead to …

    uiuc Repository record for Accelerated J-resolved proton magnetic resonance spectroscopic imaging (opens in a new tab)

  14. Exploring the Usage of U-Net-based Deep Learning Networks for Reduction of Brain PET Scan Time in Alzheimer's Disease Patients

    … biological processes. A high-quality PET scan requires a high dosage of such tracers and/or a long scan time in a PET machine, both of which can be sources of discomfort for the patient. In this work, a potential solution based on deep learning is explored, such that PET scans obtained …

    waterloo Repository record for Exploring the Usage of U-Net-based Deep Learning Networks for Reduction of Brain PET Scan Time in Alzheimer's Disease Patients (opens in a new tab)

  15. Acquisition and reconstruction methods for hybrid 2D/3D diffusion MRI

    … 2D diffusion MRI faces many limitations, such as long TR (repetition time) which lead to low SNR (signal-to-noise ratio) efficiency, and long scan times with advanced diffusion protocols which usually require a large number of diffusion directions and/or b values. These limitations become more …

    oxford Repository record for Acquisition and reconstruction methods for hybrid 2D/3D diffusion MRI (opens in a new tab)

  16. Accelerating MRI with Deep Learning: From Anatomic to Quantitative Imaging

    … diagnostic quality, resulting in a 10-30 minutes scan time. Such a long scan time might increase motion artifacts and the patient's discomfort. To perform parameter mapping, conventional methods require repeated scans of the same anatomical structure with varying sequence parameters, which limits …

    buffalo Repository record for Accelerating MRI with Deep Learning: From Anatomic to Quantitative Imaging (opens in a new tab)

  17. Undersampling to accelerate time-resolved MRI velocity measurement of carotid blood flow

    … measurement of such information but long scan time limits its clinical application in this area. In order to reduce scan time the MRI signal is often undersampled by skipping part of the signal during data acquisition. The aim of this work is to implement and evaluate different …

    edinburgh Repository record for Undersampling to accelerate time-resolved MRI velocity measurement of carotid blood flow (opens in a new tab)

  18. QUANTITATIVE T2 MAPPING USING ACCELERATED 3D STACK-OF-SPIRAL GRADIENT ECHO READOUT

    … data at different echo times, which leads to long scan time. The purpose of this thesis is to develop a rapid and accurate T2 mapping protocol with 3D high-resolution and whole- brain coverage using optimized spiral acquisition, accelerated reconstruction, and model fitting. To implement rapid …

    jhu Repository record for QUANTITATIVE T2 MAPPING USING ACCELERATED 3D STACK-OF-SPIRAL GRADIENT ECHO READOUT (opens in a new tab)

  19. Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications

    … noise ratio (SNR), incomplete fat suppression or long scan times in some challenging clinical applications, such as MR Neurography, abdominal imaging, whole-body imaging and diffusion-weighted imaging. The research in this thesis aims to improve and develop MR sequences and reconstruction methods …

    utswmed Repository record for Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications (opens in a new tab)

Page 1 of 3