Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"Look-Locker"”.
-
Assessment of hepatic fibrosis and inflammation with Look-Locker T1 Mapping and Magnetic Resonance Elastography with histopathology as reference standard
… diagnosis of cirrhosis prospectively underwent look-locker inversion recovery T1 mapping and MRE. T1 relaxation time and liver stiffness (LS) were measured by two readers. Hepatic fibrosis and inflammation were histopathologically staged according to a standardized fibrosis (F0-F4) and …
-
Metody MR relaxometrie pro měření v nehomogenním radiofrekvenčním poli
… spinových ech pro simultánní měření T1 a T2, a Look-Locker metoda umožňující rychlé mapování T1. Pro zvýšení přesnosti byly zavedeny rozšířené modely, například Look-Locker s globálním parametrem B1+ a EPG (extended phase graphs) model pro data RAREVTR, zohledňující nehomogenitu pole B1+ a …
-
Development of Frequency-modulated Techniques for MRI of Fast Relaxing Spins
… system has been shown. Secondly, a 3D Look-Locker T1 mapping method for radial sampling sequence was developed and implemented in the SWIFT sequence. The ability of the developed SWIFT Look-Locker method to provide quantitative distribution of the IONPs at high concentration is verified …
-
Development of native and contrast enhanced magnetic resonance imaging for the characterization of cardiovascular disease
… for vessel wall imaging. It however requires a Look Locker scan to choose the correct inversion time (TI) to achieve post-contrast blood suppression. The quadruple inversion recovery (QIR) sequence was later developed to suppress blood before and after contrast using identical imaging …
-
Image registration in quantitative inversion recovery MRI and applications in heart and lungs
… accidental respiratory motion in Modified Look Locker Inversion Recovery (MOLLI) sequences for cardiac T1 mapping is presented and compared to an established, alternative method. The method presented produces synthetic images via an inversion recovery model. It is shown that both methods …
-
Nicht-invasive Beurteilung des Myokards durch kardiales T1-Mapping
… eines neuen Pulssequenz-Schemas („modified Look-Locker inversion recovery“ = MOLLI), welches hochauflösendes T1-Mapping für kardiale Anwendungen innerhalb eines Atemanhaltezyklus ermöglicht. In der Folge wurde diese Methode systematisch bei gesunden Probanden getestet und validiert, wobei …
-
IMAGING POTENTIAL IN SATURATION RECOVERY METHODS FOR SARCOIDOSIS PATIENTS WITH MEDICAL DEVICES
… can cause degradation in image. The modified Look-Locker inversion recovery (MOLLI) method is widely used in quantitative T1 mapping with high precision but low accuracy and susceptibility to artifact. Newer methods like saturation recovery single-shot acquisition (SASHA) may be less …
-
Improved Techniques For Acquisition and Analysis of Dynamic Contrast-Enhanced Magnetic Resonance Imaging For Detecting Vascular Permeability In The Central Nervous System
… results. To obtain fast and accurate T1 map, the Look-Locker acquisition technique was implemented with a novel and truly centric k-space segmentation scheme. In addition, an original multi-step curve fitting procedure was developed to increase the accuracy of T1 estimation. A view sharing …
-
Προηγμένοι απεικονιστικοί παραμετρικοί δείκτες μαγνητικής τομογραφίας καρδιάς (CMR), κατά την αξιολόγηση ασθενών με σημαντική στένωση αορτικής βαλβίδας και ασθενών με μυοκαρδιοπάθεια
… AL or LVH-AS were assessed with T1, T2 (modified Look-Locker inversion recovery), extracellular volume (ECV) mapping, and late gadolinium enhancement (LGE) imaging of the heart and spleen. Results: Age, left ventricular mass index, wall thickness, ejection fraction, and splenic dimensions did not …
-
Advanced methodologies for neuromodulation and quantitative MRI with MB-SWIFT
… imaging (MRI) technology, an alternating Look-Locker (aLL) method was developed to study novel MRI biomarkers such as T1? based on rotating frame MRI methods tailored to reveal neurodegeneration. Objectives and Methods: 1) For OS-ESCS, we introduced a similar OS approach for ESCS, and …
-
Myokardiale Gewebedifferenzierung bei Aortenklappenstenose mittels T1-Mapping
… wurden sechs T1-Maps in der sogenannten Modified Look-Locker Inversion Recovery Sequenz von der basalen, medialen und apikalen Ebene, jeweils vor und nach dem Kontrastmittel (KM) Gadobutrol erhoben. Die absoluten T1-Relaxationszeiten und der Verteilungskoeffizient des KM (Lambda) wurden …
-
Deep Learning-based Segmentation of Kidneys from MR Images
… model utilizing T1- weighted Modified Look-Locker Inversion Recovery (T1-MOLLI) images at multiple inversion times, and a multi-modal model incorporating diffusion-weighted imaging (DWI) and T2*-weighted image data. While the multi-channel T1-MOLLI model demonstrated strong agreement …
-
Tissue Characterisation in Acquired Heart Disease with Cardiovascular Magnetic Resonance Imaging
… ischaemic cardiomyopathy (Chapter 3). Modified Look-Locker Inversion recovery (MOLLI) T1 and extracellular mapping techniques can be applied reproducibly in health and following either bolus or split dose gadolinium administration (Chapters 4 & 5). T1 mapping provides important insights into …
-
T1-Mapping zur frühen Detektion fibrotischer Veränderungen bei Anderson-Fabry-Patienten
… MRT untersucht. Hierzu wurde eine modifizierte Look-Locker Inversion-Recovery (MOLLI)-Sequenz zur Messung der T1-Maps verwendet. Ziel war es, durch das T1-Mapping Risikopatienten (u.a. LGE-negative Patienten) früher als bisher zu identifizieren und damit zeitnah einer entsprechenden Therapie …
-
An Information Theory Model For Optimizing Quantitative Magnetic Resonance Imaging Acquisitions
… to a 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) signal model for synthetic MRI. In this framework, mutual information is used to measure the information gained by a measurement as a function of acquisition parameters, …
-
Longitudinal relaxation dynamics in white matter : experiments in NMR and MRI
… demonstrating similar T₁ biasing effects during Look-Locker and Variable Flip Angle sequences. We evaluate sources of systematic error pertinent to MRI applications. Finally, we modify the canonical Bloch-McConnell equations describing two-pool relaxation to incorporate fractional-order …
-
Manganese imaging with positron emission tomography, autoradiography, and magnetic resonance
… field strength independent inversion recovery Look-Locker sequence, and used to generate relaxation rate change and Mn concentration maps after Mn administration. These maps showed excellent quantitative agreement with PET and AR images of the same animal, confirming that MR R1 change …
-
Parametrisches T1-Mapping in der kardialen MRT
… Kontrastmittelapplikation mittels modifizierter Look-Locker inversion recovery Sequenz in mehreren Kurzachsenpositionen. Es wurden zwei unterschiedliche Kontrastmittel in unterschiedlichen Dosen angewandt (Gadoteridol 0,15 mmol/kg Körpergewicht, Gadobutrol 0,2 mmol/kg Körpergewicht). Außerdem …
-
Evaluation des diagnostischen Potenzials von MRT-basiertem T1-Mapping bei Patienten mit vermutetem und gesichertem Prostatakarzinom
… (T1-Zeit), erhoben mittels Modified Look- Locker Inversion Recovery Sequence (MOLLI), als quantitativen radiologischen Biomarker für Diagnostik des Prostatakarzinoms zu evaluieren: 1) zur Detektion von Primärtumoren sowie 2) zur Detektion von Lymphknotenmetastasen des …
-
Der Einfluss der räumlichen Auflösung und der Kontrastmitteldosis auf die kardiale T 1-Relaxationszeit bei der kardialen Magnetresonanztomographie
… free-precession) basierenden Modified Look-Locker-Inversion-Recovery (MOLLI) Pulssequenz wurden 29 gesunde Probanden in zwei separaten T 1-Mapping Scans an einem 3 Tesla MRT untersucht. Es wurden drei verschiedene native T 1-Mapping Akquisitionen mit den unterschiedlichen Voxelgrößen …
Page 1 of 2