Copper Micro-channel Loop Thermosyphon
… construct and analyze the performance of a loop thermosyphon prototype. The design stage included a pressure loss analysis to ensure working fluid circulation. Analytical, numerical and experimental analyses were performed to calculate the heat transfer coefficient and heat transfer and to …
-
State Feedback Control of a Single-Loop Thermosyphon System Via a Quotient Controller
… to stabilize a chaotic flow in a single loop thermosyphon system with a high heat index. The thermosyphon loop is heated from below and cooled from above, which causes time-dependent chaotic flow when the external heat index is above a threshold value. Our goal was to stabilize the fluid …
-
Numerical and experimental investigations on capillary-driven thin-film evaporation with applications in pumped two-phase loop and loop thermosyphon
… a mechanical-capillary-driven (hybrid) two-phase loop (HTPL) was used as a test platform to study the capillary-driven thin-film evaporation at a system level. Deionized water is the working fluid for the HTPL. A computational model for the HTPL using a thermal-hydraulic network was developed to …
-
Experimental Investigation and Numerical Simulation of Loop Thermosyphons
… NPCHP is not a new device as suggested but is a loop thermosyphon with very high fill ratio. This effort focuses on proving the NPCHP, as an overfilled loop thermosyphon, is an effective heat transfer device through experiments and numerical simulations. An analysis of the operation and …
-
Characterization of Heat Exchange for Additively Manufactured Components
… of SLM 3D-printed evaporators in a two-phase loop thermosyphon. To achieve the first objective, a high-accuracy steady-state guarded method was developed to measure the effective conductivity of AM components. First, this apparatus was employed to measure the thermal conductivity of several …
-
Supercritical Fluids: Critical Point, Anomalous States, and Transport Behavior
… Concurrently, a supercritical natural convection loop (thermosyphon) facility is built for future investigations of the supercritical convective heat transfer. Critical property data for sulfur hexafluoride are acquired using an off-the-shelf apparatus. Recommendations are made for future …
-
Parametric Design of a Manifold for a Hollow Micropillar Evaporator for use in High Heat Flux Applications
… assembled and are tested to seal up to 15 bar. A loop thermosyphon utilizing the evaporator was developed and shown to evaporate the refrigerant and create a two phase cycle, however full data was not able to be collected on the experiment. The developments presented in this thesis provides the …
-
Análise de circuito de termossifão bifásico aplicado à parte fria de sistemas stirling de refrigeração: [dissertação]
… work investigated the performance of a two-phase loop thermosyphon (TPLT), using carbon dioxide as refrigerant fluid and operating under typical conditions of a Free-Piston Sitrling Cooler (FPSC). The basic characteristic of the problem inhabits in the transport of a heat transfer rate of 600W …
-
Elaboration d'un modèle détaillé d'une boucle diphasique gravitaire et développement d'un modèle réduit associé
Les systèmes électriques occupent de nos jours une place de plus en plus importante dans le domaine du transport aérien, ferroviaire et automobile. Ce progrès s'est accompagné de la miniaturisation des systèmes(convertisseurs) qui nécessitent un refroidissement très performant. Alors que les …
-
Passive cooling of data centers : modeling and experimentation
L'objectif de cette étude est de concevoir un système de refroidissement passif au sein d'un data center. La solution qui a été choisie est la boucle thermosiphon, combinant le free cooling et le refroidissement par changement de phase. Cette technologie offre de la simplicité et de la compacité. …
-
Simulation numérique d’une boucle biphasique gravitaire par la méthode Volume-of-Fluid
L’avancée remarquable de l’électronique de puissance s’est accompagnée de la miniaturisation des systèmes, nécessitant un refroidissement très performant. Une des solutions consiste à utiliser des boucles fluides diphasiques, dans lesquelles le transfert de chaleur est associé au changement d’état …
-
Refroidissement d'une armoire de Télécommunication avec Bouche Diphasique Thermosyphon
France Télécom possède des armoires de télécommunication dont la puissance est limitée à cause de la dissipation thermique des équipements actifs qui entraîne une augmentation de leur température interne. La puissance des équipements limite le nombre de clients qu'il est possible de connecter aux …