Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 151 for “"Loop-mediated isothermal amplification"”.
-
Development of loop-mediated isothermal amplification for rapid diagnostics
… for decentralized or resource-limited settings. Loop-Mediated Isothermal Amplification (LAMP) technology offers a faster and simpler alternative, but traditional LAMP assays face limitations, including the inability to quantify pathogen load, cold-chain dependency, limited multiplexing, and …
-
On-chip parallel detection of foodborne pathogens using loop-mediated isothermal amplification
… device capable of performing nucleic acid amplification will enable effective detection of infectious agents in multiple settings, allowing better enforcement of food safety regulations. Current protocols and practices for control of agents responsible for foodborne disease will become …
-
An Integrated Array-based Microfluidic Device for Parallel Loop-Mediated Isothermal Amplification (LAMP)
… during the cycles. To overcome this limitation, isothermal amplification methods have been developed which function at constant temperatures and help reduce the need for state-of-the-art machines to perform the amplification. Among isothermal amplification methods, LAMP (loop mediated isothermal …
-
Loop-Mediated Isothermal Amplification for Diagnosis of Major Infectious Diseases in Resource-Limited Settings
… (LMICs). With the recent development of Loop-Mediated Isothermal Amplification (LAMP), researchers are hoping to bring rapid and inexpensive point-of-care diagnostics, based on nucleic acid amplification, to LMIC settings. We ex-plored the possibility of a portable, low-cost LAMP-based …
-
Nachweis von toxinogenen Isolaten von Stachybotrys chartarum mit einem Loop-mediated Isothermal Amplification (LAMP) – Assay
… verwendet, die loop-mediated isothermal amplification (LAMP). Bei dieser Methode wird unter Verwendung von vier Oligonucleotid Primern unter isothermalen Bedingungen innerhalb einer Stunde die Ziel-DNA amplifiziert (Notomi et al., 2015; Notomi et al., 2000). Die …
-
Multiplexed detection of infectious pathogens using on-chip loop-mediated isothermal amplification and a smartphone
New tools are needed to enable rapid detection, identification, and reporting of infectious pathogens in a wide variety of point-of-care applications that impact human and animal health. In this work, we report the design, construction, and characterization of a platform for multiplexed analysis of …
-
Loop Mediated Isothermal Amplification Assay for the Detection of Antimicrobial Resistance in E. coli Bloodstream Infections
… blood culture. Current rapid nucleic acid amplification tests (NAATs) require real-time detection and are predominantly PCR based, which necessitates the use of expensive amplification and detection equipment. This research aimed to develop a loop mediated isothermal amplification (LAMP) …
-
Loop mediated isothermal amplification based detection of equine respiratory pathogens using a portable, smartphone-based setup
… approximately 30 minutes. Our approach utilizes loop mediated isothermal amplification (LAMP) reagents pre-deposited into distinct lanes of the microfluidic chip, which, when exposed to target nucleic acid sequences from the test sample, generates fluorescent products that, when excited by …
-
SENSITIVE AND SPECIFIC DETECTION OF SARS-COV-2 IN SALIVA USING REVERSE TRANSCRIPTASE LOOP-MEDIATED ISOTHERMAL AMPLIFICATION
A novel coronavirus called SARS-CoV-2 has caused the emergency release of the most well-known molecular assay, the CDC N1 RT-PCR assay, causing reports of poor analytical performance resulting in false-negative results (20, 26), and inconsistent testing kits received (23, 32). An immediate and dire …
-
Point-of-Care Electroflotation of Dispersed, Low Tolerance Pathogens Improves Detection Rates by Loop Mediated Isothermal Amplification
… with and without EF treatment in a standardized loop mediated isothermal amplification (LAMP) assay targeting a single-copy gene (glycerate kinase) in E. coli 25922. By this method reliable detection (~>95 %) of E. coli 25922 by LAMP was achieved at concentrations down to 102 CFU / mL, …
-
DEVELOPMENT OF A RAPID DIAGNOSTIC ASSAY FOR THE COLORIMETRIC DETECTION OF LEGIONELLA BACTERIA USING LOOP MEDIATED ISOTHERMAL AMPLIFICATION
… species. This project aims to develop a Loop Mediated Isothermal Amplification (LAMP) assay that can detect multiple species of Legionella in less than one hour. LAMP utilizes four primers, a strand displacing DNA polymerase, and a single incubation temperature to amplify DNA from a …
-
Development of a colourimetric loop mediated isothermal amplification assay for the detection of Mycoplasma bovis in bovine milk samples
… aimed to develop and evaluate a colourimetric loop mediated isothermal amplification (LAMP) assay as a rapid, sensitive and specific tool for detecting M. bovis in raw bovine milk samples. We developed a colorimetric LAMP assay through the incorporation of DNA enzymes (DNAzymes). We …
-
Loop-mediated isothermal amplification (LAMP) for the diagnosis of human sleeping sickness: towards a point-of-care diagnostic test
… of infection. This study focuses upon LAMP (loop-mediated isothermal amplification) as a novel diagnostic for sleeping sickness that may serve to bridge the gap between the need for sensitive, specific molecular diagnostics on the one hand and ‘field-friendly’ diagnostics on the other. Here, …
-
A Rapid Colorimetric Peptide Nucleic Acid Loop-Mediated Isothermal Amplification Assay for the Detection of the IDH1 Mutation in Glioblastoma
… a novel colorimetric peptide nucleic acid loop-mediated isothermal amplification (PNA-LAMP) method that rapidly detects the IDH1 R132H mutation in GBM. PNA-LAMP amplifies target DNA under isothermal conditions with high specificity and speed. The PNA prevents amplification of wild-type IDH1 …
-
Bestimmung des MDR1 (Multidrug resistance 1)-Genstatus beim Hund mittels allel-spezifischer PCR und allel-spezifischer Loop-mediated Isothermal Amplification (LAMP)
… wäre. Abhilfe könnte hier die Methode der Loop-mediated Isothermal Amplification (LAMP) schaffen. Im Bereich des Erregernachweises wird sie heute bereits als Point-of-Care (POC)-Test eingesetzt, da die Reaktion schnell abläuft und in einfachen, kleinen Geräten durchgeführt werden kann …
-
Development and Application of Serogroup-independent and Serogroup-specific Loop-mediated Isothermal Amplification Assays for Detecting Shiga Toxin-Producing Escherichia coli
… non-O157 STEC infections in the United States. Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification technology that has attracted great attention in recent years as a rapid, accurate, and cost-effective pathogen detection method in both food testing and clinical …
Page 1 of 8