Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Louvered fins"”

  1. Thermo-hydraulic study of inclined louvered fins

    … the air side. To increase the heat transfer rate fins are added on the airside which increase the surface area. Over the past decades a considerable amount of research has been performed to improve the performance of fin-andtube heat exchangers: e.g. transfer the same amount of heat with a smaller …

    ghent Repository record for Thermo-hydraulic study of inclined louvered fins (opens in a new tab)

  2. Practical Applications of Delta Winglets in Compact Heat Exchangers with Louvered Fins

    … industry in systems that cool engine components. Louvered fin heat exchangers are used over their continuous fin counterparts because of the significant advantages they provide in heat transfer efficiency, while only causing small increases in overall pressure losses. With the recent emphasis that …

    vt Repository record for Practical Applications of Delta Winglets in Compact Heat Exchangers with Louvered Fins (opens in a new tab)

  3. Spatially Resolved Heat Transfer Studies in Louvered Fins for Compact Heat Exchangers

    … heat transfer study of six scaled up louvered fin geometries that are typical of those found in modern louvered fin compact heat exchangers. Heat transfer measurements were performed over a range of Reynolds numbers and with two different boundary conditions. A fully heated boundary …

    vt Repository record for Spatially Resolved Heat Transfer Studies in Louvered Fins for Compact Heat Exchangers (opens in a new tab)

  4. Numerical Simulation of the Steady-State, Thermal-Hydraulic Performance of Microchannel and Minichannel Evaporators with Headers and Louvered Fins

    … minichannel and microchannel tubes with louvered fins and headers was developed and validated. The model provides the user with the option of selecting from several published correlations when calculating the air-side and refrigerant-side heat transfer and pressure drop within the control …

    ohiolink Repository record for Numerical Simulation of the Steady-State, Thermal-Hydraulic Performance of Microchannel and Minichannel Evaporators with Headers and Louvered Fins (opens in a new tab)

  5. Evaluation of Internal Fin Geometry for Heat Transfer Enhancement in Automobile Exhaust Energy Harvesting Systems

    … generators using two different internal fins — louvered fins and herringbone wavy fins. The multi-louvered fins basically have 'multi flat plate' behavior and will enhance the heat transfer by deflecting the air from its original path and aligning it with the plane of the louvers. …

    vt Repository record for Evaluation of Internal Fin Geometry for Heat Transfer Enhancement in Automobile Exhaust Energy Harvesting Systems (opens in a new tab)

  6. Performance evaluation of louvered fin compact heat exchangers with vortex generators

    … heat transfer surface area is enlarged by adding fins to the air side of the heat exchanger. When a high compactness is needed, complex interrupted fin surfaces are used. A typical example is the louvered fin design. The main disadvantage of the louvered fins is the high pressure drop. Delta …

    ghent Repository record for Performance evaluation of louvered fin compact heat exchangers with vortex generators (opens in a new tab)

  7. Unsteady flow and heat transfer in periodic complex geometries for the transitional flow regime

    … precluding common interrupted surfaces such as louvered fins. Although acceptable continuous surface geometries such as bumped fin geometries are in use, the impacts of changing the parameters of this geometry are unknown. This study investigates the transport characteristics of bumped fins in …

    must-thes Repository record for Unsteady flow and heat transfer in periodic complex geometries for the transitional flow regime (opens in a new tab)

  8. Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers

    Microhannel heat exchangers with louvered folded fins are subjected to frequent frost and defrost cycles when used in outdoor evaporator coils of air-source heat pump systems. Despite their potential for heat transfer enhancements, understanding the root causes that penalize microchannel heat …

    okstate Repository record for Measurements of Frost Growth on Louvered Folded Fins of Microchannel Heat Exchangers (opens in a new tab)

  9. Air-cooled condensers for thermoelectric power generation

    … include a parametric study on plain, wavy, and louvered fins to determine an optimal fin choice prior to additional enhancements. Experimental data from novel, oscillating reed technology designed to improve heat transfer within the air channels are implemented into the model to further optimize …

    gatech Repository record for Air-cooled condensers for thermoelectric power generation (opens in a new tab)

  10. Heat Transfer Measurements and Optimization Studies Relevant to Louvered Fin Compact Heat Exchangers

    … contain tubes carrying one fluid and external fins through which passes another fluid. To enhance the fin-side heat transfer in a compact heat exchanger, which is typically the air side of the heat exchanger, louvers are manufactured into the fins. Louvered fins initiate the growth of new …

    vt Repository record for Heat Transfer Measurements and Optimization Studies Relevant to Louvered Fin Compact Heat Exchangers (opens in a new tab)

  11. Review, Design and Computational Study of Some Compact Heat Exchangers

    … such as plain fin and tube, wavy fin and tube, louvered fin and tube, plain plate fins, wavy fins, offset strip fins, louvered fins and their correlations have been discussed. Using these correlations, in Chapter 2, two heat exchangers, a plain fin and tube heat exchanger and a compact plate fin …

    ohiolink Repository record for Review, Design and Computational Study of Some Compact Heat Exchangers (opens in a new tab)

  12. Measurements and Predictions of the Heat Transfer at the Tube-Fin Junction for Louvered Fin Heat Exchangers

    … investigation, a scaled-up model of the louvered fin-tube wall was tested in a flow facility. Although computational results for the isothermal tube wall are shown, control of the experimental isothermal tube wall proved to be unrealistic and only heat transfer measurements along the …

    vt Repository record for Measurements and Predictions of the Heat Transfer at the Tube-Fin Junction for Louvered Fin Heat Exchangers (opens in a new tab)