Showing 1 to 10 of 10 for “"Low Cardiac Output Syndrome"”.
-
A clinical appraisal of propofol-mediated, antioxidant-based cardioprotection during coronary artery bypass grafting with cardiopulmonary bypass
… encounter a postoperative complication known as low cardiac output syndrome which can quadruple the overall mortality rate for CABG. Intraoperative ischemia reperfusion injury is a major factor in the development of low cardiac output syndrome; so effective intraoperative myocardial protection is …
-
Pažintinių funkcijų sutrikimai po vainikinių arterijų jungčių suformavimo operacijų ir juos predisponuojantys perioperaciniai rizikos veiksniai /
… are independent preoperative predictors of POCD. Low cardiac output syndrome detected postoperatively for more than 48 hours, was three fold increasing the risk of POCD. Patients experiencing POCD were treated in ICU for a significantly longer period of time, even in the absence of cardiovascular …
-
Η επίδραση του levosimendan στη μυοκαρδιακή λειτουργία σε επεμβάσεις αορτοστεφανιαίας παράκαμψης
… as a loading dose of 12γ/kg during 10 min followed of 10γ/kg/min. Dobutamine was started as a continuous infusion of 10γ/kg/min. After 10 min interval, an upward adjustment to 20 γ/kg/min could be made if clinically indicated. Our results not only confirm the findings of previous studies but …
-
Aortic Valve Replacement: The Influence of Prosthesis-Patient Mismatch for Left Ventricular Remodeling, Cardiac Function and Survival
… mismatch on left ventricular remodeling following aortic valve replacement for severe valve insufficiency. The present work demonstrated that PPM was not associated with low cardiac output syndrome, but rather an independent risk factor for a neurological event during the postoperative …
-
Development, validation and application of analytical methods to measure prognostic biomarkers in patients receiving on-pump coronary artery bypass grafting surgery
… of Detection (LOD), Limit of Quantitation (LOQ), Lower Limit of Quantitation (LLOQ) and stability were found satisfactory. Concentrations of 15-F₂t₋isoprostane, 3-nitrotyrosine and adenosine were found to rise after on-pump CABG surgery. However, these changes were not able to explain the …
-
Development of paediatric dosage forms of furosemide using the problem structuring method of morphological analysis
… as a solution space for paediatric patients with low cardiac output syndrome. Morphological Analysis application resulted in the selection of two different dosage forms for further work (Microemulsion oral liquid dosage form and an Orodispersible Mini-tablet). The furosemide microemulsion …
-
Die Rolle der prophylaktischen Implantation einer intraaortalen Ballonpumpe auf dem kurzfristigen Outcome nach einer elektiven koronaren Bypass-Operation mit Einsatz der Herz-Lungen-Maschine bei den Patienten mit einer hochgradig eingeschränkten linksventrikulären Pumpfunktion
… Risiko zur Entwicklung eines postoperativen Low Cardiac Output Syndrome (LCOS) verbunden. Das LCOS ist eine schwere Form der akuten Herzinsuffizienz, die als sehr gefürchtete und schwerwiegende Komplikation nach einer Herzoperation auftreten kann. Dieses Syndrom geht mit einer deutlich …
-
Effects of peri-operative statin treatment on atrial electrical properties, post-operative atrial fibrillation and in-hospital clinical outcomes in patients undergoing elective cardiac surgery
… of postoperative atrial fibrillation (POAF) and low cardiac output syndrome in patients undergoing cardiac surgery. Statins have been shown to exert rapid anti-inflammatory and antioxidant effects by inhibiting myocardial NOX2 oxidases and by increasing the bioavailability of nitric oxide (NO). …
-
Evaluation of minimal access proximal thoracic aortic surgery
Minimal access approaches in cardiac surgery and for procedures on the aortic valve began to develop in the 1990s. Several variations were performed in search of the most appropriate technique before the median ministernotomy was established. Despite limited exposure, difficult deairing or …
-
Αντιμετώπιση ασθενών με χαμηλή καρδιακή παροχή που υποβάλλονται σε εγχειρήσεις καρδιάς με τη χρήση συσκευής υποβοήθησης της αριστερής κοιλίας διαδερμικής τοποθέτησης
… devices (VADs) are used in 0.2%-1.2% of all cardiac surgical cases. The hospital discharge rate with temporary VADs as “bridge to recovery” in the post-cardiotomy setting remains low (20%-60%). This study evaluates a recently developed VAD (TandemHeart pVAD, Cardiac Assist, Pittsburgh, PA) in …