Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Low Voltage Grid"”.

  1. Control of DC Power Distribution Systems and Low-Voltage Grid-Interface Converter Design

    … system-level control to improve load sharing, voltage regulation and efficiency; (b) design of a high-efficiency interface converter to connect dc microgrids with the existing low-voltage ac distributions, with a special focus on common-mode (CM) voltage attenuation. Droop control has been used …

    vt Repository record for Control of DC Power Distribution Systems and Low-Voltage Grid-Interface Converter Design (opens in a new tab)

  2. A Study on Voltage Issues Caused by Photovoltaic Installations on the Low Voltage Grid in New Zealand Residential Conditions

    … and the challenges it brings in terms of voltage quality i.e. voltage, imbalance sag and swell. It examines previous work conducted and extensions which should be investigated. The thesis analyses the voltage power quality guidelines proposed by the Electricity Authority and their validity …

    auckland-tech Repository record for A Study on Voltage Issues Caused by Photovoltaic Installations on the Low Voltage Grid in New Zealand Residential Conditions (opens in a new tab)

  3. Variable structure virtual impedance approaches for improving power flow control of grid-connected power converters

    … distributed generators (DG), in the electrical grid. However, because of the intermittent nature of the energy in solar radiation and wind, control strategies for regulating the DG power flow are necessary to ensure a proper connection of these systems to the grid. These control strategies are …

    brazil-ufrn Repository record for Variable structure virtual impedance approaches for improving power flow control of grid-connected power converters (opens in a new tab)

  4. Impact of plug in electric vehicle battery charging on a distribution system

    … battery chargers are mostly connected to the low-voltage grid for charging, hence their increased penetration coupled with uncoordinated charging could impact the distribution system in terms of voltage unbalance and transformer overloading. Although PEV battery charging is increasing, impact …

    utc Repository record for Impact of plug in electric vehicle battery charging on a distribution system (opens in a new tab)

  5. Aspectos do desempenho operativo de redes elétricas com inserção de geração fotovoltaica

    … generation. Therefore, a distribution grid was proposed by combining a medium and low voltage systems and also, by adding distributed photovoltaic generation at the low voltage grid. Furthermore, the IEEE 39 bus system was chosen for the transmission grid studies, also by adding central …

    brazil-uerj Repository record for Aspectos do desempenho operativo de redes elétricas com inserção de geração fotovoltaica (opens in a new tab)

  6. Constructing realistic synthetic load profiles based on privacy-sensitive residential smart meter data

    … to accelerate the energy transition on the low-voltage grid. These data can be used to develop tailored innovative technology solutions and maximize their efficiency, as well as to increase the number of renewable technologies on the grid by creating additional flexibility. However, public …

    ghent Repository record for Constructing realistic synthetic load profiles based on privacy-sensitive residential smart meter data (opens in a new tab)

  7. Cascaded H bridge based solid state transformer for Medium Voltage and Low voltage interface, Simulation and Analysis.

    … paper presents a smart way to interface a medium voltage grid with low voltage grid as a response to rapidly growing penetration of distributed Energy resources (DES) in the power system grid. With renewable energy resources and distributed storages ever increasing, the complexity to manage loads …

    ttu Repository record for Cascaded H bridge based solid state transformer for Medium Voltage and Low voltage interface, Simulation and Analysis. (opens in a new tab)

  8. Methods for evaluating the implications of the transition to carbon neutrality on the power grid

    Today’s power grid infrastructure was not built for a decarbonized energy economy and is consequently slowing the transition to CO2-neutrality. Worldwide, renewable energy projects totaling roughly 3 TW of capacity are delayed for lack of grid-connection capacity; some are never realized. In …

    freiburg-diss Repository record for Methods for evaluating the implications of the transition to carbon neutrality on the power grid (opens in a new tab)

  9. Advanced control architectures for grid connected and standalone converter systems

    … computational burden and stability in grid-connected and stand-alone based power electronic converter systems applicable for ac microgrids.</p><p>Two voltage sensorless control architectures, one for stand-alone applications and the other for grid-connected application are established …

    must-thes Repository record for Advanced control architectures for grid connected and standalone converter systems (opens in a new tab)

  10. Design and simulation of a single-phase inverter with grid support functions

    … the operation and stability of the electrical grid, at all voltage levels. Utilities and system operators, among others, have worked towards the development of interconnection standards and test procedures for these types of resources in order to mitigate the impact of their increasing …

    ets-quebec Download PDF for Design and simulation of a single-phase inverter with grid support functions (opens in a new tab)

  11. Design and Development of a Direct Medium Voltage Solar PV Resonant Inverter

    In a grid-tied photovoltaic (PV) system connected to a medium voltage (MV) grid, an inverter is generally employed with a line frequency transformer (LFT) to connect to the grid. These LFTs are large in size and weight, exhibit high cost and losses. In recent studies, the LFTs replaced by are by …

    south-carolina Repository record for Design and Development of a Direct Medium Voltage Solar PV Resonant Inverter (opens in a new tab)

  12. Managerial guidelines for microgrids in an urban context; demonstration at Karlastaden

    … problem is one of the main concerns. Microgrids have the potential to reduce this problem and additionally increase the value streams for the real estate owner. The aim of the thesis is to conceptually design managerial guidelines for evaluating the financial feasibility of microgrids. The …

    chalmers Repository record for Managerial guidelines for microgrids in an urban context; demonstration at Karlastaden (opens in a new tab)

  13. Integration studies for New Zealand Low-Voltage Distribution Networks with Inverter-based Energy Systems.

    … of distributed energy resources, especially on Low Voltage grid. The uncontrolled market and reducing price of inverter based energy systems means increased penetration of renewable generation on varying topologies. However, current network planning strategies can successfully take distributed …

    auckland-ms Repository record for Integration studies for New Zealand Low-Voltage Distribution Networks with Inverter-based Energy Systems. (opens in a new tab)

  14. Zukünftige Belastungen von Niederspannungsnetzen unter besonderer Berücksichtigung der Elektromobilität

    Aktuell finden umfangreiche Neuerungen und Veränderungen im Elektroenergiesystem statt. Dabei stellen die Netzintegration von Energiespeichern, EE-Anlagen und Elektrofahrzeugen sowie die Realisierung von Energiemanagementsystemen wichtige Neuerungen in der Niederspannungsebene dar. Analysen der …

    qucosa-diss

Page 1 of 2