Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Low dose CT"”.

  1. Denoising Low-Dose CT Images using Multi-frame techniques

    … examines potential methods of achieving a reduction in X-ray radiation dose of Computer Tomography (CT) using multi-frame low-dose CT images. Even though a single-frame low-dose CT image is not very diagnostically useful due to excessive noise, we have found that by using multi-frame low-dose …

    sask Repository record for Denoising Low-Dose CT Images using Multi-frame techniques (opens in a new tab)

  2. Low dose CT perfusion: filtering the way to the clinic

    CT perfusion is a method in which multiple CT scans are taken in succession, after contrast medium has been administered to the patient. This allows the radiologist to see where and when blood enters body parts. The disadvantage of this method is that many CT scans must be made, which results in a …

    radboud Repository record for Low dose CT perfusion: filtering the way to the clinic (opens in a new tab) Download PDF for Low dose CT perfusion: filtering the way to the clinic (opens in a new tab)

  3. A 3D Deep Learning Architecture for Denoising Low-Dose CT Scans

    … designed to improve the image quality of low-dose computed tomography (LDCT) scans. Although LDCT scans are advantageous for reducing radiation exposure, they inherently suffer from reduced image quality. Our novel 3D DL architecture addresses this issue by effectively enhancing LDCT …

    vt Repository record for A 3D Deep Learning Architecture for Denoising Low-Dose CT Scans (opens in a new tab)

  4. Enhancing Quality of Low-Dose CT Scans Via Generative Diffusion Models

    The enduring challenge in computed tomography (CT) imaging is mitigating the radiation risks associated with high-dose protocols while maintaining image quality. This research introduces an innovative approach that diverges significantly from conventional methodologies, using Generative Diffusion …

    mcmaster Repository record for Enhancing Quality of Low-Dose CT Scans Via Generative Diffusion Models (opens in a new tab)

  5. Dynamic Fluence Field Modulation for Low-Dose CT Using Multiple Aperture Devices

    X-ray Computed Tomography (CT) is a major imaging modality used in a wide variety of clinical cases in modern medicine, but has raised public concerns over increasing population radiation exposure. While traditional dose-saving solutions, such as the bowtie filter, have been in use for several …

    jhu Repository record for Dynamic Fluence Field Modulation for Low-Dose CT Using Multiple Aperture Devices (opens in a new tab)

  6. Automatic colonic polyp detection using curvature analysis for standard and low dose CT data

    … deaths in the developed nations. Early detection and removal of colorectal polyps via screening is the most effective way to reduce colorectal cancer (CRC) mortality. Computed Tomography Colonography (CTC) or Virtual Colonoscopy (VC) is a rapidly evolving non-invasive technique and the …

    dcu Download PDF for Automatic colonic polyp detection using curvature analysis for standard and low dose CT data (opens in a new tab)

  7. High-Speed Reconstruction of Low-Dose CT Using Iterative Techniques for Image-Guided Interventions

    … view and ease of operation, Computed-Tomography(CT) is increasingly the choice for IGIs. The risk of radiation exposure, however, limits its current and future use. We perform ultra low-dose scanning to overcome this limitation. To address the image quality problem at low doses, we reconstruct …

    maryland Repository record for High-Speed Reconstruction of Low-Dose CT Using Iterative Techniques for Image-Guided Interventions (opens in a new tab)

  8. Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach

    Computed Tomography (CT) imaging is widely used in the clinic for numerous applications like disease screening scans for cancer, lung nodules or internal bleedings, routine exams of bone or head injuries, and radiotherapy planning. However, radiation exposure of patients during CT examinations is a …

    tamu Repository record for Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach (opens in a new tab) Embargoed until 2027-08-01

  9. Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach

    Computed Tomography (CT) imaging is widely used in the clinic for numerous applications like disease screening scans for cancer, lung nodules or internal bleedings, routine exams of bone or head injuries, and radiotherapy planning. However, radiation exposure of patients during CT examinations is a …

    tamu Repository record for Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach (opens in a new tab) Embargoed until 2027-08-01

  10. Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach

    Computed Tomography (CT) imaging is widely used in the clinic for numerous applications like disease screening scans for cancer, lung nodules or internal bleedings, routine exams of bone or head injuries, and radiotherapy planning. However, radiation exposure of patients during CT examinations is a …

    tamu Repository record for Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach (opens in a new tab) Embargoed until 2027-08-01

  11. Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach

    Computed Tomography (CT) imaging is widely used in the clinic for numerous applications like disease screening scans for cancer, lung nodules or internal bleedings, routine exams of bone or head injuries, and radiotherapy planning. However, radiation exposure of patients during CT examinations is a …

    tamu Repository record for Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach (opens in a new tab) Embargoed until 2027-08-01

  12. Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach

    Computed Tomography (CT) imaging is widely used in the clinic for numerous applications like disease screening scans for cancer, lung nodules or internal bleedings, routine exams of bone or head injuries, and radiotherapy planning. However, radiation exposure of patients during CT examinations is a …

    tamu Repository record for Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach (opens in a new tab) Embargoed until 2027-08-01

  13. Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach

    Computed Tomography (CT) imaging is widely used in the clinic for numerous applications like disease screening scans for cancer, lung nodules or internal bleedings, routine exams of bone or head injuries, and radiotherapy planning. However, radiation exposure of patients during CT examinations is a …

    tamu Repository record for Opportunities and Challenges in Low-Dose CT Imaging: A PCA-Based Latent Diffusion Approach (opens in a new tab) Embargoed until 2027-08-01

  14. A Power-Law noise scheduler for image diffusion models in low-dose CT denoising

    … imaging has led to the widespread adoption of low-dose computed tomography protocols, guided by the principle of ALARA (As Low As Reasonably Achievable). However, lowering the radiation dose results in increased image noise and artifacts, which can significantly compromise diag nostic quality. …

    brazil-ufpe Repository record for A Power-Law noise scheduler for image diffusion models in low-dose CT denoising (opens in a new tab)

  15. FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES

    … of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual …

    cornell Repository record for FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES (opens in a new tab)

  16. Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging

    … Mismatch of PET data with computed tomography (CT) attenuation correction (CTAC) due to respiratory motion is a known source of errors in PET imaging. In theory, this can be corrected by matching individual PET and CT phases which have been generated by respiratory-correlated PET and CT. …

    washington Repository record for Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging (opens in a new tab)

  17. Task-specific observer performance and image quality : direct and indirect relationships in low-dose CT images

    … of this research was to examine image quality in low-dose CT images, as determined by a range of image quality measures (IQM), in addition to psychophysical assessment, and look at direct or indirect relationships. Method: CT images of an anthropomorphic chest phantom were obtained using …

    salford Download PDF for Task-specific observer performance and image quality : direct and indirect relationships in low-dose CT images (opens in a new tab)

Page 1 of 4