Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 381 for “"Low field"”.

  1. High Hopes for Low-Field: Investigating the Potential of Low-Field NMR Spectroscopy in Environmental Research

    … that is informative, reliable, and accessible, allowing scientists to monitor, protect, and remediate the environment. Nuclear Magnetic Resonance (NMR) spectroscopy is one such powerful tool, as it has unparalleled structure elucidation capabilities, and is non-targeted, non-destructive, and has …

    toronto-retro Repository record for High Hopes for Low-Field: Investigating the Potential of Low-Field NMR Spectroscopy in Environmental Research (opens in a new tab)

  2. Low Field Nuclear Spin Optical Rotation

    … of the NSOR experiment is its intrinsic low signal-to-noise ratio (SNR). The most straightforward way of solving this problem is to increase the polarization level of nuclear spins. In this work, by using the dissolution dynamic nuclear polarization (DNP) technique, the polarization level …

    tamu Repository record for Low Field Nuclear Spin Optical Rotation (opens in a new tab)

  3. A low field nuclear magnetic resonance spectrometer

    … the "spin-spin relaxation time" in liquids at low fields using the "spin-echo" technique. An outline of some basic ideas in nuclear magnetic resonance discussing the meaning of T₁ and T₂ is presented. This includes a comparison of steady state and pulsed techniques. The theoretical aspects, …

    ubc Repository record for A low field nuclear magnetic resonance spectrometer (opens in a new tab) Download PDF for A low field nuclear magnetic resonance spectrometer (opens in a new tab)

  4. Effects of Low Field Magnetic Stimulation on

    … of life, there is no approved treatment for it. Low Field Magnetic Stimulation (LFMS) is a novel non-invasive brain stimulation technique that has promising benefits in improving mood and cognitive function in animal studies of traumatic brain injury, major depressive disorder and Alzheimer’s …

    sask Repository record for Effects of Low Field Magnetic Stimulation on (opens in a new tab)

  5. APPLICATIONS OF LOW FIELD MAGNETIC RESONANCE IMAGING

    … scanners used in the clinical setting are high field systems because they have a magnetic field strength greater than 1.5 Tesla. The high magnetic field offers the benefit of high spatial resolution and high SNR. However, low filed systems can also produce high resolution MR images with the …

    u-pacific Repository record for APPLICATIONS OF LOW FIELD MAGNETIC RESONANCE IMAGING (opens in a new tab)

  6. A Fusion Proton Diagnostic for Low Field Tokamaks

    … of fast particles within the plasma of low field tokamaks such as the Mega Amp Spherical Tokamak is explored. The minimum number of detector elements in a pinhole-type detector needed to produce accurate images of the plasma was found to be 144, giving a 5cm by 5cm resolution of the …

    whiterose Download PDF for A Fusion Proton Diagnostic for Low Field Tokamaks (opens in a new tab)

  7. Efficient magnet configuration for low-field nuclear magnetic resonance applications

    … small, portable magnet while maintaining strict field homogeneity. This work presents novel annulus designs as well as implementations of the previously researched Halbach array. The annulus designs, although competitive in field strength, lack the required homogeneity for NMR applications. …

    texas Repository record for Efficient magnet configuration for low-field nuclear magnetic resonance applications (opens in a new tab)

  8. MOLECULE SPECIFIC CONTRAST USING ULTRA-LOW-FIELD MAGNETIC RESONANCE IMAGING

    … atomic spins to detect and measure magnetic fields. Low-field MRI using atomic magnetometers with improvements in the spatial resolution and sensitivity can be made more competitive with conventional MRI systems. In the present thesis we report the improvement of spatial resolution of …

    houston Repository record for MOLECULE SPECIFIC CONTRAST USING ULTRA-LOW-FIELD MAGNETIC RESONANCE IMAGING (opens in a new tab)

  9. Low Field Transport Calculations in TiS3 Using Ab-Initio Methods

    … structure and transport properties. We show that low field electron mobility is limited by the optical phonon scattering mechanism, which explains the large discrepancy between experimentally measured mobility and calculated mobility in previous reports. First, ab-initio calculations are performed …

    buffalo Repository record for Low Field Transport Calculations in TiS3 Using Ab-Initio Methods (opens in a new tab)

  10. Low-Field and High-Field Anisotropic Carrier Transport in SiC

    付記する学位プログラム名: 京都大学卓越大学院プログラム「先端光・電子デバイス創成学」

    kyoto Repository record for Low-Field and High-Field Anisotropic Carrier Transport in SiC (opens in a new tab)

  11. Combined ultra-low-field MRI and MEG: instrumentation and applications

    … imaging (MRI) is a noninvasive method that allows the study of the interior structure of matter. Today, MRI is widely used in medical diagnosis and research, thanks to its versatile contrast and the lack of ionizing radiation. Conventionally, the signal-to-noise ratio of an MRI measurement …

    aalto Repository record for Combined ultra-low-field MRI and MEG: instrumentation and applications (opens in a new tab)

  12. Ultra-low field Magnetic Resonance Imaging using high-Tc SQUIDs

    A measurement system for ultra-low field Magnetic Resonance Imaging (ulf-MRI) has been built and programmed and a few proof-of- principle 2D images of water phantoms have been acquired at 89.3 μT measurement field. The smallest detectable volume of water has been de- termined to be 0.3 cm3. A …

    chalmers Repository record for Ultra-low field Magnetic Resonance Imaging using high-Tc SQUIDs (opens in a new tab)

  13. Radio Frequency Power Amplifiers Adapted For Low Field Magnetic Resonance Imaging

    … conventional MRI systems have is making them low field. This leads to lighter, smaller, simpler and less expensive MRI scanners that can potentially become portable. Once they are portable, MRI scanners can have various applications ranging from being used in emergency and operating rooms to …

    sask Repository record for Radio Frequency Power Amplifiers Adapted For Low Field Magnetic Resonance Imaging (opens in a new tab)

  14. Profiling of Relaxation Time and Diffusivity Distributions with Low Field NMR

    … Two NMR pulse sequences are introduced that allow for the determination of relaxation time or diffusion-relaxation time distributions as a function of sample height. One-dimensional T 2 and D-T 2 profiles can be determined with a low-field Maran Ultra spectrometer by implementing nuclear …

    rice Repository record for Profiling of Relaxation Time and Diffusivity Distributions with Low Field NMR (opens in a new tab)

  15. Machine Learning And Quantitative Neuroimaging In Epilepsy And Low Field Mri

    … ways to automate medical processing and produce lower-cost medical imaging devices. Recent advances in deep learning and low-field MRI hardware offer potential solutions, providing lower-cost methods for processing and collecting images, respectively. This thesis aims to develop and validate …

    penn Repository record for Machine Learning And Quantitative Neuroimaging In Epilepsy And Low Field Mri (opens in a new tab)

  16. A homogeneous RF-shielded magnet for low-field magnetic resonance studies

    … magnetic resonance imaging (MRI) systems have B0-fields of 1.5 − 7.0T, and research usage time on these high-field systems is limited and expensive. The development of novel MRI techniques, such as transmit array spatial encoding (TRASE), can be accelerated by access to in-house, small-scale, …

    manitoba Repository record for A homogeneous RF-shielded magnet for low-field magnetic resonance studies (opens in a new tab)

  17. Method development for ultra-low-field magnetic resonance imaging and magnetoencephalography

    Ultra-low-field (ULF) magnetic resonance imaging (MRI) can be combined with magnetoencephalography (MEG) in a hybrid MEG-MRI device using superconducting quantum interference device (SQUID) sensors for measuring both MRI (structural imaging) and MEG (functional imaging) signals. The MEG-MRI device, …

    aalto Repository record for Method development for ultra-low-field magnetic resonance imaging and magnetoencephalography (opens in a new tab)

  18. Ultra-low-field MRI: techniques and instrumentation for hybrid MEG-MRI

    … Conventionally, MRI is performed in magnetic fields above 1 T. On the other hand, magnetoencephalography (MEG) is a tool for functional brain imaging. In modern MEG, an array of highly sensitive superconducting quantum interference device (SQUID) sensors is used to measure the weak magnetic …

    aalto Repository record for Ultra-low-field MRI: techniques and instrumentation for hybrid MEG-MRI (opens in a new tab)