Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"Low frequency impedance"”

  1. Degradation in lead zirconate titanate thin film capacitors for non-volatile memory applications

    … of the number of fatigue cycles is presented. Impedance and modulus spectroscopic techniques have been applied to study the effect of degradation on the ferroelectric thin film. It has been shown that with accurate low frequency impedance measurement equipment, new insight can be gained on the …

    vt Repository record for Degradation in lead zirconate titanate thin film capacitors for non-volatile memory applications (opens in a new tab)

  2. Electroanalytical Techniques for Digital Microfluidics

    … particular interest, reducing complexity and allowing real-time monitoring. Many techniques including optical and mass spectrometric methods were established previously, but until recently there were few reports of electrochemical detection being employed with DMF. Electrochemical analysis …

    toronto-retro Repository record for Electroanalytical Techniques for Digital Microfluidics (opens in a new tab)

  3. Improved membrane absorbers

    … into two novel techniques for improving the low frequency performance, tunability and efficiency of membrane absorbers. The first approach uses a loudspeaker surround as the mounting for the membrane, increasing the moving mass, thereby lowering the resonant frequency of the system. Using a …

    salford Repository record for Improved membrane absorbers (opens in a new tab)

  4. Modeling the Frequency Response of the Graphene/Electrolyte Interface in Electrochemical Systems

    … on graphene’s voltage-dependent capacitance, its frequency response remains underexplored theoretically. This thesis develops a rigorous mathematical framework to model and analyze the frequency response of the graphene/electrolyte interface under diverse conditions, including finite-conductivity …

    waterloo Repository record for Modeling the Frequency Response of the Graphene/Electrolyte Interface in Electrochemical Systems (opens in a new tab)

  5. Electrochemical studies of coatings and thin films

    … on coated Al electrode. Electrochemical Impedance Spectroscopy (EIS) cannot accurately sense the initial degradation of protective coatings as they are just starting to fail because the low frequency impedance is typically higher than the input impedance of the EIS system for …

    ohiolink Repository record for Electrochemical studies of coatings and thin films (opens in a new tab)

  6. Electrical impedance tomography at low frequencies.

    … systems demonstrate dispersions of electrical impedance characteristics at very low frequencies below 2 kHz due to the presence of membrane surrounding the cells and diffusion polarisation effects. A study was made on the feasibility of the use of low frequencies in a range of 1.12 Hz to 4.55 …

    unsw Repository record for Electrical impedance tomography at low frequencies. (opens in a new tab)

  7. The recovery of subsurface reflectivity and impedance structure from reflection seismograms

    … the problem of estimating broadband acoustic impedance from normal incidence reflection seismograms. This topic is covered by following the linear inverse formalisms described by Parker (1977) and Oldenburg (1980). The measured seismogram is modelled as a convolution of subsurface reflectivity …

    ubc Repository record for The recovery of subsurface reflectivity and impedance structure from reflection seismograms (opens in a new tab)

  8. Performance Characterization and Modelling of a Lithium-Ion Cell using Electrochemical Impedance Spectroscopy

    … (SOC) values. An equivalent circuit model for impedance modelling is proposed, which utilizes constant phase elements represented in the time domain to improve fitting accuracy. This is done concurrently with the development of a state of the art, fully automated battery test system which is …

    mcmaster Repository record for Performance Characterization and Modelling of a Lithium-Ion Cell using Electrochemical Impedance Spectroscopy (opens in a new tab)

  9. PREDICTION OF ROCK AND FLUID PROPERTIES USING MACHINE LEARNING, MULTI-SCALE SHORT TIME FOURIER TRANSFORM, AND ROCK PHYSICS

    … between compressional-wave and shear-wave impedances. Application to a wide variety of well log and laboratory measurements suggests that the empirically optimized weighting may differ from direct theoretical calculations made using Gassmann’s equations. Combining laboratory and log …

    houston Repository record for PREDICTION OF ROCK AND FLUID PROPERTIES USING MACHINE LEARNING, MULTI-SCALE SHORT TIME FOURIER TRANSFORM, AND ROCK PHYSICS (opens in a new tab)

  10. Embedded Reference Electrodes for Corrosion Potential Monitoring, Electrochemical Characterization, and Controlled-Potential Cathodic Protection

    … Harrison’s solution. Zn primer on steel had low accuracy in comparison. This is in part due to short circuiting by Zn oxidation products, which are much more conductive than Mg corrosion products. Data interpretation was improved through statistical analysis. On average, ERE corrosion …

    ndsu Repository record for Embedded Reference Electrodes for Corrosion Potential Monitoring, Electrochemical Characterization, and Controlled-Potential Cathodic Protection (opens in a new tab)

  11. Giant Magneto-impedance Effect In Thin Film Layered Structures

    Recently, the giant magneto impedance (GMI) effect has been studied extensively because of its potential applications in sensor elements. The focus of this thesis work is to explore different compositions and processing conditions for CoSiB and NiFe thin films to obtain the soft magnetic properties …

    ucf Repository record for Giant Magneto-impedance Effect In Thin Film Layered Structures (opens in a new tab)

  12. UNDERSTANDING CO OXIDATION IN SOFC'S USING NICKEL PATTERNED ANODE

    … under dry and wet conditions. Electrochemical impedance spectroscopy (EIS) and voltammetry were used to quantify the patterned anode performance. Adding ~ 3% H2O to CO/CO2 anode flows increased electrochemical oxidation rates by almost 2X for temperatures between 700 and 800 °C. This can …

    maryland Repository record for UNDERSTANDING CO OXIDATION IN SOFC'S USING NICKEL PATTERNED ANODE (opens in a new tab)

  13. Extended Bandwidth Doherty Power Amplifier for Carrier Aggregated Signals

    … peak to average power ratio. This results in low average efficiency for power amplifiers, which in turn results in heavy cooling requirements and damage to the environment. To improve the low back-off efficiency Doherty technique has been widely investigated. But, the conventional Doherty …

    waterloo Repository record for Extended Bandwidth Doherty Power Amplifier for Carrier Aggregated Signals (opens in a new tab)

  14. Radiation Study of the Organic Photovoltaic Cell P3HT:PCBM

    … reduced efficiency is compensated for by their lower weight. This leads to a higher specific power and hence a lower load for launch. Furthermore, their flexibility is a particularly positive attribute since this renders them less vulnerable to vibration damage during the launch process. It must …

    unm Repository record for Radiation Study of the Organic Photovoltaic Cell P3HT:PCBM (opens in a new tab)

  15. Concurrent Dual-band Doherty Power Amplifiers for Carrier Aggregation

    … Doherty power amplifier (DPA), which allows the transmitter remain in high efficiency at back-off power levels and maintain that high efficiency over multiple frequency bands. In this work, a novel output combining network is presented for the dual-band DPA design with extended …

    waterloo Repository record for Concurrent Dual-band Doherty Power Amplifiers for Carrier Aggregation (opens in a new tab)

Page 1 of 2