Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 64 for “"Low frequency vibration"”
-
Low-frequency vibration inspection of sandwich composite
… honeycomb, balsa, or foam cores, often relies on low-frequency vibration techniques to detect defects by identifying changes in amplitude or phase response. However, existing methods are often tailored to detect specific defect types, potentially overlooking others, and lack the capacity to …
-
INERTIAL AMPLIFICATION METASTRUCTURES FOR LOW FREQUENCY VIBRATION AND NOISE CONTROL
… has provided a new technique for vibration and noise reduction in lightweight thin-walled struc-tures such as cabin walls in low frequency range. By orderly designing microstructures at subwavelength scales, acoustic metastructures can effectively manipulate the propagation of …
-
Smart Nanocoated Structure for Energy Harvesting at Low Frequency Vibration
… can be used as a means of transforming ambient vibrations into electrical energy that can be stored and used to power other devices. With the recent surge of micro scale devices, piezoelectric power generation can provide a convenient alternative to traditional power sources. In this research, a …
-
Low-Frequency Vibration Attenuation Using Multi Degree of Freedom Quasi-Zero Stiffness Systems
Low-frequency vibration is harmful and difficult to attenuate due to resonance. Since the natural frequency of a system is directly proportional to stiffness, reducing stiffness is advantageous. However, there are limitations to how far stiffness can be reduced while supporting a given mass. The …
-
NEURAL BASIS OF VIBRATION DETECTION IN LEPIDOSAURIAN REPTILES
… potential pathways for detection of substrate vibration: cochlear, otolithic and somatosensory, reviewed in chapter one. How different lepidosaurian reptiles detect substrate vibration from these three pathways was explored from neuroanatomical and physiological perspectives. In chapter two, I …
-
The effect of whole body vibration-induced post-activation potentiation upon indices of isometric and dynamic force/power production during, and following a six-week periodised Smith machine back squat protocol.
… training program, with (G2) or without (G3) low frequency vibration upon select force characteristics, as well as to changes in body composition. Methods. Participants (G1 n = 6; G2 n = 13; G3 n = 11; ranged in age from 18 to 30 years) were randomized into either a 6 wk periodized Squat …
-
Complex 3D Microstructures Assembled by Compressive Buckling for Low Vibrational Piezoelectric Energy Harvesting
… with a fixed support are widely adopted for low frequency vibration-based energy harvesters. The three-dimensional (3D) nature of vibrations constitutes limitations in efficiency for the simple two-dimensional (2D) geometries of traditional devices. In this research, a uniquely designed 2D …
-
Human response to vibration from earthmoving machines.
The study was concerned with the low frequency vibration generated by wheeled earth moving machines and the consequent discomfort or fatigue risks for the drivers. For these machines the vertical, 'Z', axis was established as the direction of vibration propogation presenting greatest potential …
-
Noise Characerization For Proposed UCF Phyiscal Science Building Sites.
Today's Advance Technology Facilities require low noise levels and increased noise monitoring. Ambient noise can interfere with the accuracy and precision of experiments and manufacturing processes. Therefore preconstruction site surveys are needed to develop strategies for mitigating noise. …
-
Segmented active constrained layer damping treatments
<p>Active vibration control of flexible robotic arms is important for improving their overall accuracy and efficiency. The objective of this research is to demonstrate the feasibility of applying the concept of Active Constrained Layer Damping treatment to reduce the level of vibration in flexible …
-
Age-related changes in Meissner Corpuscles of Diabetic Mice as Observed by Electron Microscopy
Light touch and low-frequency vibration sense are often impaired in diabetic patients. Meissner corpuscles are distally located mechanoreceptors that respond to these stimuli. Peripheral sensory neuropathy in diabetes progresses from distal to proximal, therefore, Meissner corpuscles are ideally …
-
High-Performance Accelerometer Based On Asymmetric Gapped Cantilevers For Physiological Acoustic Sensing
… healthcare field. Because of the miniature size, low cost, and easy installation, accelerometer is an excellent choice for continuous physiological acoustic signal monitoring. However, in order to capture the detailed information in the physiological signals for clinical diagnostic purpose, there …
-
Micro Power Harvesting using Flexible Thermoelectric and Electromagnetic Vibration-based Power Generators
… power generator (FTEG) and electromagnetic vibration-based power generator (EVMPG). The design, modeling, development, and analyses of a FTEG and a low-frequency vibration based T-shaped cantilever type EVMPGs are detailed in this thesis. A manual dispenser printing-based fabrication …
-
Development of a low-cost method for whole-spacecraft isolation of small satellites
Force-limited vibration testing (FLVT) is effective in reducing the low-frequency vibration test environment for CubeSats on the Naval Postgraduate School CubeSat Launcher (NPSCuL); however, the CubeSats are still subjected to high-frequency amplifications above 500 Hz from the NPSCuL structure. …
Page 1 of 4