Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 41 for “"Low global warming potential"”
-
INVESTIGATION OF HOUSEHOLD REFRIGERATOR WITH ALTERNATIVE LOW GLOBAL WARMING POTENTIAL REFRIGERANTS
… the drop-in performance of several alternative low global warming potential (GWP) refrigerants in the household refrigerator. The alternative refrigerant of strongest interest was HFO-1234yf, which was evaluated as a direct drop-in replacement for HFC-134a. HFO-1234yf was found to be a suitable …
-
Heat transfer performance and prediction of low global warming potential R134a refrigerant alternatives
… environmental regulations are phasing out high global warming potential (GWP) refrigerants such as R134a. Since many potential alternative refrigerants have flammability and cost concerns, minimizing system charge is critical. The condenser is typically responsible for 50% of the charge of a …
-
Study of Low Global Warming Potential Refrigerants in Heat Pump System for Residential Applications
… flammable. HFO-1234yf is a refrigerant with low GWP (GWP = 4, zero ODP) that is currently being used in European car market as a possible replacement for R134a. This thesis focuses on an experimental comparison of the drop-in energy performance and capacity of two low GWP refrigerants in a …
-
Performance Evaluation of Industrial Waste Heat Driven Power Cycles Utilizing Low Global Warming Potential Working Fluids
… Most waste heat recovery systems utilize high global warming potential working fluids, which are hazardous to the environment. The objective of this research is to evaluate the thermodynamic and economic performance of power cycles utilizing low global warming potential working fluids for waste …
-
ANALYSIS OF LOW GLOBAL WARMING POTENTIAL FLUORIDE WORKING FLUIDS IN VAPOUR COMPRESSION SYSTEMS. EXPERIMENTAL EVALUATION OF COMMERCIAL REFRIGERATION ALTERNATIVES
… commercial refrigeration. In this thesis, some low-GWP alternatives to replace the most commonly used HFC refrigerants in commercial refrigeration are evaluated, taking into account the limitations imposed by these regulations. To carry out this evaluation, the current status of parallel …
-
Capacity based performance predictions for positive displacement compressors with low-GWP refrigerants through compressor modeling
… replace current refrigerants with those having low Global Warming Potential (GWP). To select suitable refrigerants for different applications, low-GWP refrigerants' performance evaluation in various positive displacement compressors is crucial. A carefully designed simulation model can provide …
-
Evaluation and optimisation of energy-efficient heat pump integrated into different applications for simultaneous cooling and heating with alternative refrigerants
… ejectors, PV/T panels, waste heat recovery, and low-global warming potential (GWP) refrigerants. A comparative study of various low-GWP refrigerants was conducted to determine the performance of the proposed system under different conditions and waste heat levels. Initially, the system was …
-
Effect of electrohydrodynamics on thermal dissipation for high voltage thermosyphons
… has been considerable interest in selecting low global warming potential coolants to replace Hydrofluorocarbons (HFCs) and Perfluorocarbons (PFCs). Thermal properties of Hydrofluoroethers (HFE) and Fluorinated ketone (FK) are similar to HFCs, whilst they have low global warming potential …
-
Analysis and optimization of a dual-load vapor compression cycle using non-azeotropic refrigerant mixtures
… Mixtures (NARMs) have been identified as potential replacements for R12 because of their low ozone depletion potential, low global warming potential and promising thermodynamic characteristics which could improve cycle efficiency. A NARM experiences a variable temperature glide during a …
-
Copper Micro-channel Loop Thermosyphon
… and heat transfer with the fin theory, and flow over a flat surface. The numerical analysis was performed using the computational fluid dynamics software Fluent. The experimental work was conducted on a small-scale wind tunnel under constant air flow, 0.5 and 1.0 m/s, and different operating …
-
Calculation of Electron Collision Cross Sections in Fluorinated Nitrile (C4F7N) and its Dissociation Fragments
… gas due to its higher dielectric strength and low global warming potential relative to SF6. To evaluate the behavior of this novel gas during high-voltage gaseous discharges, plasma models require electron-neutral collision cross sections to calculate parameters such as transport coefficients. …
-
Predictive Modeling For Multiphase Flow Boiling Heat Transfer By Integrating Computational Fluid Dynamics And Machine Learning Approaches
The heat transfer process in multiphase flow systems becomes essential forindustrial applications and when phase change occurs. The heat transfer coefficients become more efficient during boiling and condensation processes when compared to single-phase fluid flow. The design of thermal systems …
-
Performance and Capacity Comparison of Two New Lgwp Refrigerants Alternative to R410a in Residential Air Conditioning Applications
This thesis presents a ground breaking study on Low Global Warming Potential (LGWP) developmental refrigerants. An R410A 17.6 kW (5 ton) heat pump split unit commercially available off-the-shelf for US ducted HVAC applications, was retrofitted with two new developmental refrigerants, DR-4 and DR-5 …
-
Integrating Life Cycle Assessment and Material Suitability Testing: Selection of Sustainable Foams for Supporting Artifacts in a Canadian Context
… artifacts, consisting of recycled content low-density polyethylene (LDPE) foams, a biodegradable LDPE foam, a bio-based foam, and Canadian-made virgin LDPE foams. A life cycle analysis (LCA) using secondary data from the ecoinvent (version 3.9.1) lifecycle inventory database, manipulated …
-
Nanoscale modification of key surface parameters to augment pool boiling heat transfer and critical heat flux in water and dielectric fluids
… constituency on boiling mechanisms is revealed. Low surface tension dielectric fluids, including a recently developed fluorinated ketone with a low global warming potential, are tested to determine their pool boiling heat transfer capabilities. The potential for nanoparticle-based pool boiling …
-
Design and Lab Implementation of an Air Source Transcritical CO2 Heat Pump
… was developed to evaluate the performance of low-global-warming-potential (GWP) refrigerants for cold climate applications. A custom climate chamber was also constructed to simulate winter weather conditions typical of the northeastern United States. Both the TCHP and the chamber were fully …
-
Design and construction of a pumped refrigerant loop for commercial scale low-GWP refrigerant heat exchanger testing
… for refrigerant conditioning is developed to allow testing of heat exchangers using a wide range of refrigerants, including low global warming potential refrigerants. The pumped refrigerant loop can be connected to the tested heat exchanger within the OSU Psychometric Coil Testing Facility. The …
-
Modelo dinâmico para um evaporador operando com R-1234yf e R134a
… in refrigeration processes because they have low ozone depletion potential (ODP) and low global warming potential (GWP). With the emergence of restrictions such as the European Directive 2006/40 / EC and EU No. 517/2014, refrigerants with GWP above 150, such as R-134a, are now subject to study …
-
Alternative refrigerant mixtures to Isobutane (R-600a): energy efficiency enhancement and flammability reduction
… widely used in Europe for domestic and low-capacity commercial refrigeration due to its low global warming potential (GWP) and good energy properties, is limited by its high flammability, restricting the maximum refrigerant charge and cooling capacity. This research identifies potential …
Page 1 of 3