Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 55 for “"Low voltage ride through"”

  1. Low voltage ride-through of permanent magnet synchronous generator wind energy systems

    Low Voltage Ride-Through (LVRT) capability is considered a critical feature that should be implemented within a Wind Energy Conversion System (WECS). The mismatch produced between the generated active power and the power delivered to the grid during any dip incidence at the Point of Common Coupling …

    strathclyde Repository record for Low voltage ride-through of permanent magnet synchronous generator wind energy systems (opens in a new tab)

  2. Low Voltage Ride-Through for Indirect Matrix Converter Based Open-End Winding Drives

    … storage mechanism, which could be used for ride-through operations during fault conditions. In some applications like wind turbines, the presence of large capacitive and reactive components in the drive could be a drawback due to lesser reliability and increased weight. Hence, converters …

    umn Repository record for Low Voltage Ride-Through for Indirect Matrix Converter Based Open-End Winding Drives (opens in a new tab)

  3. Reactive power-based voltage support for the low voltage ride through capability of the distributed energy resource

    … inverters within the distribution grid at the low voltage (LV) level. Most of the grid codes require the wind and the PV park to remain connected during shortcircuit grid faults and also provide reactive power-based voltage support. Meanwhile, a growing number of DERs will be connected onto the …

    soton Repository record for Reactive power-based voltage support for the low voltage ride through capability of the distributed energy resource (opens in a new tab)

  4. Low voltage ride-through capability for matrix converter fed adjustable-speed Induction machine drives for industrial and wind applications.

    … its application wherever bidirectional power flow and controlled voltage and current in AC systems is needed and proves to be superior to its competitors when applied in certain specific environments and circumstances. Wind energy conversion systems (WECS) are also a recent growing research …

    umn Repository record for Low voltage ride-through capability for matrix converter fed adjustable-speed Induction machine drives for industrial and wind applications. (opens in a new tab)

  5. Capability of DFIGs to Provide Reactive Power Support and Low Voltage Ride Through in Hybrid Wind Farms with FSIGs

    This thesis examines the low voltage event performance of hybrid wind farms containing both economical Fixed Speed Induction Generators (FSIGs) and the increasingly popular but more costly Doubly-Fed Induction Generators (DFIGs). Of particular interest is the ability of DFIGs, through manipulation …

    washington Repository record for Capability of DFIGs to Provide Reactive Power Support and Low Voltage Ride Through in Hybrid Wind Farms with FSIGs (opens in a new tab)

  6. Advanced control techniques for doubly fed induction generator-based wind turbine converters to improve low voltage ride-through during system imbalances

    … to wind power generation is under study for low voltage ride-through application during system disturbances. Conventional dq axis current control using voltage source converters for both the grid side and the rotor side of the DFIG are analyzed and simulated. DFIG operation is investigated …

    must-thes Repository record for Advanced control techniques for doubly fed induction generator-based wind turbine converters to improve low voltage ride-through during system imbalances (opens in a new tab)

  7. Large wind farm aggregation and model validation

    … one equivalent single machine to study the load flow and stability? How well does the equivalent single machine capture the behavior of the large wind farm during a simulation study? 2. When a short circuit happens in a large wind farm, some wind turbines trip while others do not. What is the …

    uiuc Repository record for Large wind farm aggregation and model validation (opens in a new tab)

  8. Design, analysis and simulation of a new current controller for wind power generation system using proportional plus resonance control.

    … Moreover, using the proposed current controller, voltage transient characteristics of WPGS are analyzed and a control scheme is introduced to meet the low-voltage ride-through standard. All analysis and evaluation have been conducted for a 250kW WPGS with 208V grid voltage.

    baylor Repository record for Design, analysis and simulation of a new current controller for wind power generation system using proportional plus resonance control. (opens in a new tab)

  9. Control strategies of MMC-HVDC connected to large offshore wind farms for improving fault ride-through capability

    This paper proposes strategies to improve fault ride-through (FRT) capability of the modular multi-level converter (MMC) - high voltage direct current (HVDC) system connected to large offshore wind farms and performs simulations. In offshore wind power plants, HVDC system is indispensable for …

    umn Repository record for Control strategies of MMC-HVDC connected to large offshore wind farms for improving fault ride-through capability (opens in a new tab)

  10. Modeling of industrial power distribution circuits for voltage sag and fault analysis

    … to simulate sensitive electrical loads during voltage sags. The study begins by discussing the modeling procedure for induction motors based on manufacturer datasheets. It then investigates and develops a 24-pulse variable frequency drive (VFD) model in EMTP. The functionality of the VFD model …

    texas Repository record for Modeling of industrial power distribution circuits for voltage sag and fault analysis (opens in a new tab)

  11. Unified Control Strategy for Microgrid Solid-State Transformers

    … is uniquely software-based and ii) An efficient low-voltage ride-through (LVRT) scheme. Both of those functions come at no extra cost using the proposed unified control scheme. These proposals further demonstrate the proposed strategy’s ability to accommodate further features and modifications. A …

    york Repository record for Unified Control Strategy for Microgrid Solid-State Transformers (opens in a new tab)

  12. Wind energy and power system interconnection, control, and operation for high penetration of wind power

    … control scheme is proposed to enhance the low-voltage ride-through capability of wind turbines equipped with doubly fed induction generators. Stator-voltage transient compensation terms are introduced to suppress rotor-current overshoots and torque ripples during grid faults. A dynamic …

    gatech Repository record for Wind energy and power system interconnection, control, and operation for high penetration of wind power (opens in a new tab)

  13. Mitigating the erosion of transient stability margins in Great Britain through novel wind farm control techniques

    The predominant North-to-South active power flow across the border between Scotland and England has historically been limited by system stability considerations. As the penetration of variable-speed wind power plants in Great Britain grows (reducing the generation share of traditional synchronous …

    strathclyde Repository record for Mitigating the erosion of transient stability margins in Great Britain through novel wind farm control techniques (opens in a new tab)

  14. Grid Connected Doubly Fed Induction Generator Based Wind Turbine under LVRT

    This project concentrates on the Low Voltage Ride Through (LVRT) capability of Doubly Fed Induction Generator (DFIG) wind turbine. The main attention in the project is, therefore, drawn to the control of the DFIG wind turbine and of its power converter and to the ability to protect itself without …

    bologna Repository record for Grid Connected Doubly Fed Induction Generator Based Wind Turbine under LVRT (opens in a new tab)

  15. Συμβολή της αιολικής διείσδυσης στην ευστάθεια των συστημάτων ηλεκτρικής ενέργειας

    … on power system stability, mainly short-term voltage stability and small-signal stability. Emphasis is given on Doubly Fed Asynchronous Generator (DFAG) which is the most popular scheme used today in wind generators. However, many conclusions refer to the other category of full-converter …

    greece Repository record for Συμβολή της αιολικής διείσδυσης στην ευστάθεια των συστημάτων ηλεκτρικής ενέργειας (opens in a new tab)

  16. Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível

    … to electrical disturbances, especially voltage sags since the stator is directly connected to the grid. This feature highlights a fundamental challenge which is to provide fault support. Given this problem’s relevance, this thesis proposes improving DFIG supportability to a voltage sag …

    brazil-ufrn Repository record for Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível (opens in a new tab)

  17. Wind Mills and Transmission System Interaction

    … of power system disturbances and their impact on voltage profile at the point of wind power connection. The study of the different wind turbine types is made to find out their low voltage ride through capability. Finally, the behaviour of wind turbines at the point of grid connection is analysed …

    chalmers Repository record for Wind Mills and Transmission System Interaction (opens in a new tab)

  18. Evaluating, planning, and ranking of multi-infeed HVDC systems using unified control performance indices

    … replacing aging line-commutated converters with voltage-sourced converters to improve controllability and fault resilience. However, conventional planning indices remain largely static and are often treated as separate metrics, making it difficult to consistently rank modernization options across …

    manitoba Repository record for Evaluating, planning, and ranking of multi-infeed HVDC systems using unified control performance indices (opens in a new tab)

  19. Mathematical Modelling of Grid Connected Fixed- Pitch Variable-Speed Permanent Magnet Synchronous Generators for Wind Turbines

    … (SVPWM) inverter, and a model of the power grid voltage sag detection for low voltage ride through (LVRT). The rectifier is a 3-phase uncontrolled diode full-bridge circuit. The boost chopper circuit offers a direct current (DC) power supply with constant voltage for the inverter. Sampled signals …

    cent-lancashire Repository record for Mathematical Modelling of Grid Connected Fixed- Pitch Variable-Speed Permanent Magnet Synchronous Generators for Wind Turbines (opens in a new tab)

  20. A Study of Cyber-Attack Resilience in a DER-Integrated Synthetic Grid Based on Industry Standards and Practices

    … their impacts on steady state stability, voltage drop, and production and marginal costs related to analyzing the effects of DER failure. In this study, we consider the next-generation Low Voltage Ride-Through requirements for DERs as established by (North American Electric Reliability …

    tamu Repository record for A Study of Cyber-Attack Resilience in a DER-Integrated Synthetic Grid Based on Industry Standards and Practices (opens in a new tab)

Page 1 of 3