Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 24 for “"Low-Energy X-Rays"”
-
Development of new dosimetric standards for low energy X-rays (≤ 50 keV) used in contact radiotherapy
La curiethérapie électronique, également appelée radiothérapie de contact, est une technique de traitement du cancer utilisant des rayons X de faible énergie (≤ 50 keV) générés par des tubes à rayons X miniaturisés et positionnés au contact des tissus à irradier. La miniaturisation des générateurs …
-
Dosimetry and radiobiology of ultrahigh dose-rate radiotherapy delivered with low-energy x-rays and very high-energy electrons
… of delivery. These include kilovoltage x-rays produced by a shutter-controlled x-ray tube, and very high energy electrons (VHEE) accelerated to 200 MeV at high energy physics laboratories. Testing the capability of these sources requires specialized dosimeters and radiobiological models …
-
An investigation of early radiation damage in exposed eye-lenses of rainbow trout
… damage in humans by investigating the effects of low-energy X-rays on the lenses of rainbow trout. Lenses were cultured and irradiated to doses up to 2.210 Gy with low-energy X-rays of 40 kV. Laser focal analysis was used to track changes in focal lengths across the lenses post-irradiation. The …
-
Metabolism and formation of 2-dodecylcyclobutanone in irradiated ground beef
… 10) for direct solvent extraction. The effect of low-energy X-rays on the formation of 2-DCB was investigated in frozen ground beef. Beef patties (85/15) were irradiated by low-energy X-rays and gamma rays at 3 targeted doses of 1.5, 3.0, and 5.0 kGy. The 2-DCB was extracted with n-hexane by using …
-
Position-sensitive proportional counters using resistance-capacitance position encoding
… fwhm for alpha particles and 100 µfwhm for low-energy x rays (2 to 6 keV). Also, the signal processing time was reduced to 0.6 µsec without seriously degrading the spatial resolution.</p><p>These results have opened new fields of application of the RC position encoding method in …
-
Long wavelength X-ray microanalysis
… information. Proportional counter operation with low energy x-rays is analysed and discussed, and the construction of a suitable counter is described � .Measurements of the quantum yields from carbon and aluminium, . made with this counter, are reported; these measurements, apart from their …
-
Characterization of wound monitoring systems used to quantify and locate plutonium contamination
… contaminated wounds is difficult due to the lowenergy and yield of the uranium L-shell x rays used for the measurement, which can be effected by source distance, shape, and tissue attenuation. These effects on wound counting systems used at Los Alamos National Laboratory (LANL) were …
-
Gamma Calibration Using A New Test Apparatus At Queen’s University And Optimization Analyses For The PICASSO Experiment
… droplets of freon C4F10. During the interaction, energy is deposited to the freon triggering a phase transition, inducing pressure waves which are detected by piezo-electric sensors. A temperature dependent analysis of the amplitudes of the signals for detector 71 showed that, above 25 ◦C, between …
-
Characterization of hydrides and delayed hydride cracking in zirconium alloys
… light metals such as Al or Mg (due to the use of low energy x-rays). Here we show the first DCT measurements using high energy x-rays (60 keV), allowing measurements in zirconium. A new algorithm of a computationally efficient way to characterize distributions of hydrides - in particular their …
-
Risedronate Prevents Early Bone Loss Resulting from Whole-body Irradiation
… trabecular micro-architecture have been found following exposure to multiple types of radiation. Past research has implicated reduction of osteoblast function and changes to vasculature as the primary sources of bone deterioration. Recently, an early increase in osteoclast number was observed …
-
Creating optically stimulated luminescence 3D printing filament and synthesizing radiosensitive optically stimulate luminescence crystals
… EX2 extruder, and extruding the mixture at low speed at 180 degrees Celsius. Afterward, the extruded filament was cut and re-extruded 2 more times, then warmed on a hot plate, compressed between 2 glass microscope slides, and cut into 8 mm diameter dots to create Filament Dot (FD) …
-
Probing dynamics of complex ordered phases in colossal magnetoresistive transition-metal oxides using coherent resonant soft x-ray scattering
… diffraction. By scattering highly coherent, low energy x-rays, we can measure manganite speckle: a "fingerprint' of the microscopic structure in the bulk. The coherence of the x-rays can further be used to elucidate new insight into the dynamics of these phases. We describe here a number of …
-
Production of ¹⁶⁵Er : a promising candidate for SPECT imaging and targeted Auger electron therapy of cancer
Auger electron-emitting (AEE) radionuclides with low (0.001–1 keV) energy, short range (2-500 nm), and high linear energy transfer (4–26 keV/μm) can play an important role in the targeted radionuclide therapy (TRT) of cancer. ¹⁶⁵Er (t₁/₂=10.36 h) decays 100% via electron capture and is one of a few …
-
Multiscale Modeling and Analysis of X-ray Windows, Microcantilevers, and Bioimpedance Microelectrodes
… must be thin enough to transmit sufficient low-energy x-rays, yet strong enough to withstand up to an atmosphere of differential pressure. Traditional low-energy x-ray windows consist of a support layer and pressure membrane spanning that support. Numerical modeling of several x-ray windows …
-
A Proof-of-Principle Investigation for a Neutron-Gamma Discrimination Technique in a Semiconductor Neutron Detector
… of 158Gd* involves the emission of prompt gamma rays with competing internal conversion (IC) electrons. Following the expulsion of conversion electrons from the atomic shells of 158Gd, the excitation energy of the atom is released through the emission of Auger electrons and characteristic x-rays. …
-
Algorithms for automated measurements of the radioresponse of live cells at therapeutic doses
… of cell detection, characterization, and follow-up. The primary aim of this thesis was to test the hypothesis that the algorithms necessary for generating survival data with such an automated system can be developed to standards of accuracy comparable to those of an experienced human …
-
Exploration of applications of photon-counting detector computed tomography (CT) using a table-top CT system
… of our bench-top PCD-CT scanner using a dual-energy CT (DECT) method for extracting effective atomic number (Zeff) and relative electron density (ρe) of tissues. We demonstrated that the method with PCD-CT was more accurate in extracting Zeff and ρe for a set of electron density phantom …
-
SIGNIFICANCE OF ION INDUCED LUMINESCENCE FOR RADIATION INDUCED BYSTANDER EFFECTS
… studies where the cells are exposed to very low fluence of charged particles there could be several regions that can produce electromagnetic radiation due to the process of atomic/molecular excitations and relaxations. We focused on quantifying the number of ultraviolet photons emitted when …
Page 1 of 2