Orthodontic Patients’ Experience with Low-Intensity Pulsed Ultrasound (LIPUS) Treatment
Background: Low-Intensity Pulsed Ultrasound (LIPUS) is a non-invasive adjunct to orthodontic treatment with evidence supporting its capacity to accelerate tooth movement, reduce orthodontically induced inflammatory root resorption (OITRR), and enhance bone remodelling. Despite an expanding body of …
-
Design and Safety Assessment of Wearable Transcranial Low-Intensity Pulsed Ultrasound Devices
… significant issues in the global medical burden. Ultrasound therapy has shown excellent performance in many clinical applications. Some encouraging evidence has shown that transcranial ultrasound stimulation (TUS) has a beneficial effect on relieving symptoms of mental illness (neuropsychiatric …
-
Physico-Biological Mechanisms of Focused Low-Intensity Pulsed Ultrasound in Musculoskeletal Regeneration
Ultrasound is an inexpensive, portable, and real-time mode technique, which has generated increasing interest in the medical community not only for imaging purposes, but also for tissue regeneration. Low-Intensity Pulsed Ultrasound (LIPUS) has already been demonstrated to be a safe, non-invasive, …
-
The effect of low intensity pulsed ultrasound (LIPUS) on orthodontic tooth movement: a preliminary study
INTRODUCTION Low-Intensity Pulsed Ultrasound (LIPUS) has been introduced as a promising adjunct in orthodontic care, with growing evidence suggesting it may accelerate tooth movement, reduce unwanted side effects of orthodontic treatment (specifically orthodontically induced tooth root resorption …
-
The effect of non invasive low intensity pulsed ultrasound on bone growth into porous tantalum implants
… was to evaluate the effect of non-invasive, low-intensity, pulsed ultrasound on bone growth into tantalum porous implants. Three transcortical cylindrical implants were inserted into both femora of 12 dogs. One leg underwent daily ultrasound stimulation for 40 consecutive minutes with the …
-
Design of Low-intensity Pulsed Ultrasound Device, Intensity Sensor and Its Application to Enhance Vaccine Production
The application of low-intensity pulsed ultrasound (LIPUS) technology for therapy has become a promising interdisciplinary research field in biomedical engineering. This thesis covers two important topics in the field: LIPUS design and its biological applications. In therapeutic ultrasound …
-
Mandibular Condyle Tissue Reaction to Low Intensity Pulsed Ultrasound in a Young Adult Rat Animal Model
… growth. The mechanical stimulus produced by Low Intensity Pulsed Ultrasound (LIPUS) is osteoinductive and chondroinductive. It has been reported by previous studies that the application of LIPUS on the temporomandibular joint area can enhance mandibular growth in growing individuals. The aim …
-
The Effect of Low-Intensity Pulsed Ultrasound on Extracellular Matrix and its cross-linking and organisation
… ECM components often appear to be dysfunctional. Low-intensity ultrasound, as a form of mechanical stimulation, has shown promising results at the cellular level. This project aims to investigate the effect of Low-Intensity Pulsed Ultrasound (LIPUS) on gene expression, matrix deposition, …
-
Establishment of neuronal cell models for the study of low-intensity pulsed ultrasound therapy for nerve regeneration
Although low-intensity pulsed ultrasound (LIPUS) is well highlighted as an adjunct therapeutic tool for bone regeneration, the potential therapeutic effect of LIPUS on nerve regeneration for regenerative endodontics and nerve injuries has been inadequately studied. This project aimed to investigate …
-
A study of the effects of low intensity pulsed ultrasound on bone cells using controlled in vitro exposure methods
Low Intensity Pulsed Ultrasound (LIPUS) is a type of therapeutic ultrasound approved for treatment of non-union fractures since it was found to accelerate healing in a number of in vivo and clinical studies in the 1990’s. However, recent independent clinical trials found no significant healing …
-
Expansion and Osteogenic Differentiation of Human Umbilical Cord Perivascular Stem Cells by Low Intensity Pulsed Ultrasound for Dentofacial Tissue Engineering
The objective of these experiments is to explore the effect of LIPUS on the ultraexpansion and osteogenic differentiation of harvested passage-4 HUCPV-SCs. HUCPV-SCs were divided into two groups: a treatment group that received LIPUS for 10 minutes for 1, 7, and 14 days and a control group that …
-
The Effect of Varying Intensity Levels of LIPUS (Low Intensity Pulsed Ultrasound) On The Rate of Orthodontic Tooth Movement in Mice
… rate of tooth movement changes depending on the intensity of ultrasound. There was a significant increase in the rate of tooth movement in 30 mW/cm2 group compared to 15 and 50 mW/cm2. Osteoclasts number was increased in 30 group compared to 50 and 15 mW/cm2, and also expression of important …
-
Treatment effect of Low Intensity Pulsed Ultrasound either alone, with functional appliance and with gene therapy on the mandibular condylar growth
… of this thesis was to investigate the effect of Low intensity pulsed ultrasound (LIPUS) with or without the use of forward bite jumping appliance, also known as functional appliance (FA) on the mandibular condylar growth in the rat model and also to investigate the biological effect on MC 3T3E1 …
-
Effect of low intensity pulsed ultrasound on orthodontically induced root resorption caused by torque: A prospective double blinded controlled clinical trial
… minutes per day for four weeks at an incident intensity of 30mW/cm2 of the transducers surface area. The other side served as a self-control which received a sham transducer. After 4 weeks, all first premolars were extracted for regular orthodontic treatment and a micro-CT analysis was …
-
Effects of low intensity pulsed ultrasound (LIPUS) and longitudinal cortical allograft perforation (LAP) on allograft healing: a biomechanical and histological investigation
… to investigate the effects of an exogenous, low-intensity pulsed ultrasound signal (LIPUS) either alone or in combination with increased graft cortical porosity (LAP) on allograft healing after four months in vivo. Results from this exploratory study will provide preliminary information on …
-
Characterization and Implementation of Low Intensity Pulsed Ultrasound as a Tool to Apply Physical Load to Scaffolds and Bone Cells for Fracture Repair
… treatment of non-unions and delayed unions. Low Intensity Pulsed Ultrasound (LIPUS) has been approved by the FDA to treat fresh fractures since 1994 and non-unions since 2000 and is an attractive treatment option because it is non-invasive. The mechanism by which it works, however, is not …