Characterization of Image Quality between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Clinical Used Protocols in Radiation Therapy Treatment Planning
… Diagnostic imaging is a useful tool that allows healthcare professionals to obtain anatomical and physiological information from patients’ in a non-invasive way. In Radiation Oncology, x-ray imaging is used to calculate the anatomical radiation dose as well as it can be a tool for assessing …
-
Optimierte modellbasierte Rekonstruktionsverfahren der computertomographischen Bildgebung zur besseren Darstellung von Leberläsionen
… Model-Based Iterative Reconstruction SoluTion Low Contrast Detectability (FIRST) Low Contrast Detectability (LCD), im Vergleich zu einem gängigen iterativen Rekonstruktionsalgorithmus getestet. Dazu wurden gering kontrastierte Leberläsionen verschiedener Dignität bei Patienten mit zugrunde …
-
A Comparative Image Quality Analysis between Multi-Slice Computed Tomography and Cone Beam Computed Tomography for Radiation Treatment Planning Purposes
… with one another with the exception of the low contrast detectability measurements. The effects of scatter radiation and image noise significantly reduced the cone beams ability to detect low contrast objects which ultimately degraded its image quality compared to CT.
-
An Investigative Study of a Novel Technique of Material Decomposition for Dual Energy Cone Beam Computed Tomography - Technique and Clinical Applications
… and during RT. It offers great soft-tissue contrast and submillimeter spatial resolution. Despite the widespread usage of kV CBCT, there are still areas to improve (e.g., scatter, soft-tissue delineation, and low contrast detectability). Dual-energy CBCT (DECBCT), using the multi-material …
-
PERFORMANCE OPTIMIZATION OF SEMI-STATIONARY CT FOR WHOLE BODY IMAGING
… CT number accuracy, while PWLS provided improved low-contrast detectability with spatial resolution comparable to FDK under suitable parameter settings. Studies with the anthropomorphic phantom demonstrated the expected trade-off between noise suppression and spatial resolution, and identified …
-
Calibration of medical displays
… to obtain a consistent distribution of perceived contrast throughout the gray-scale. An inconsistent contrast distribution may lead to an increased workload when reviewing and possibly an erroneous diagnosis. It is also important that a display calibration utilizes the luminance range of a display …
-
Myocardial Perfusion Imaging with X-Ray Computed Tomography
… Quantitative estimates of myocardial blood flow by myocardial perfusion imaging (MPI) can detect the physiologic impact of MVD and obstructive CAD. The combination of MPI with computed tomography (MPI-CT) and coronary CT angiography would enable rapid physiologic and anatomic evaluation of …
-
Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems
… medical and scientific community towards using lower doses has spawned new dose reduction technologies such as automatic exposure control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while …