Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Low-dose imaging"”.

  1. CONSIDERATIONS FOR LOW-DOSE IMAGING IN TRANSMISSION ELECTRON MICROSCOPY

    … models for image registration under low-dose conditions. Specifically, we have formulated a Poisson likelihood-based motion correction algorithm for low-dose images and found that electron dose fractionation over a various number of images is an optimizable factor in terms of image …

    nus Repository record for CONSIDERATIONS FOR LOW-DOSE IMAGING IN TRANSMISSION ELECTRON MICROSCOPY (opens in a new tab) Download file for CONSIDERATIONS FOR LOW-DOSE IMAGING IN TRANSMISSION ELECTRON MICROSCOPY (opens in a new tab)

  2. Low-dose imaging for particle therapy with fluence-modulated proton computed tomography

    … of tumors with energetic charged particles allows for the precise deposition of a therapeutic dose in the cancerous tissue while sparing surrounding healthy tissue. This exploits the increased dose deposition of charged particles, typically protons or carbon ions, at the end of their range. …

    lmu-germany Repository record for Low-dose imaging for particle therapy with fluence-modulated proton computed tomography (opens in a new tab)

  3. Low-dose imaging of liver diseases through neutron stimulated emission computed tomography: Simulations in GEANT4

    … (NSECT) is a non-invasive, tomographic imaging technique with the ability to locate and quantify elemental concentration in a tissue sample. Previous studies have shown that NSECT has the ability to differentiate between benign and malignant tissue and diagnose liver iron overload while …

    duke Repository record for Low-dose imaging of liver diseases through neutron stimulated emission computed tomography: Simulations in GEANT4 (opens in a new tab)

  4. Design of an x-ray CT system with implementation of sparse-data reconstruction

    … reconstruction to demonstrate capability of low-dose imaging via retrospective downsampling of acquired datasets. Reconstructed images are noise-suppresed via total variation (TV) minimization and Tikhonov regularization, using iterative solution techniques. Image quality metrics are …

    gatech Repository record for Design of an x-ray CT system with implementation of sparse-data reconstruction (opens in a new tab)

  5. Ultra high resolution imaging of radiation-sensitive materials

    … damage.</p> <p>This thesis proposes a complete low-dose high resolution imaging strategy for characterising radiation-sensitive materials using an aberration-corrected transmission electron microscope. The microscope was quantitatively calibrated for electron dose and was operated under a strict …

    oxford Repository record for Ultra high resolution imaging of radiation-sensitive materials (opens in a new tab)

  6. Indirect conversion amorphous selenium photodetectors for medical imaging applications

    … purposes, such as ultra-high resolution bone imaging, image guided interventions, dynamic CT angiography, and interventional neuroradiology. Most of these applications require low X-ray dose to limit potential harm to the patient. One of the main challenges of low dose imaging is to maintain a …

    waterloo Repository record for Indirect conversion amorphous selenium photodetectors for medical imaging applications (opens in a new tab)

  7. Improving Biospecimen Imaging in Liquid Phase Electron Microscopy

    … and electron-induced biosample damage. Low electron transmission in thick silicon nitride (SiNx) LCs reduces the achievable resolution during imaging. To address this, I developed a technique to fabricate thin SiNx windows. These windows exhibit reduced bulging, higher transmission, and …

    waterloo Repository record for Improving Biospecimen Imaging in Liquid Phase Electron Microscopy (opens in a new tab)

  8. FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES

    … of cardiovascular and lung diseases from low-dose thoracic computed tomography (CT) images. The recent regulatory approval of annual lung cancer screening (LCS) provides the opportunity for the application of these methods to a large at-risk population that will already be receiving annual …

    cornell Repository record for FULLY-AUTOMATED QUANTITATIVE ANALYSIS OF CARDIAC AND LUNG DISEASES FROM THORACIC LOW-DOSE CT IMAGES (opens in a new tab)

  9. Studying The Clinical And Research Applications Of The Pennpet Explorer, A Long Axial Field-Of-View Pet Scanner

    … of a PET scanner by 3-6 times to 70-140 cm may allow for fast, low-dose imaging and more accurate quantification using a wide variety of radiotracers. Results of performance characterization, including sensitivity, count rate, spatial resolution, and lesion contrast, showed good correspondence …

    penn Repository record for Studying The Clinical And Research Applications Of The Pennpet Explorer, A Long Axial Field-Of-View Pet Scanner (opens in a new tab)

  10. IMAGE RECONSTRUCTION AND GEOMETRICAL MODELING OF BONE CROSS SECTIONS FROM LIMITED ANGLE DUAL ENERGY PROJECTION DATA

    … however, are expensive and its radiation doses are too high for routine screening of asymptomatic populations. To address these issues, a low dose multi-projection DXA scanner system is proposed that can develop a valid bone model for mechanical analysis from limited angle dual energy …

    jhu Repository record for IMAGE RECONSTRUCTION AND GEOMETRICAL MODELING OF BONE CROSS SECTIONS FROM LIMITED ANGLE DUAL ENERGY PROJECTION DATA (opens in a new tab)

  11. Sparse reconstruction in monostatic and multistatic SAR

    … paradigms for synthetic aperture radar (SAR) imaging problems with non-conventional SAR configurations. Conventional SAR systems with collocated transmit and receive antennas are designed for imaging of stationary ground scenes over narrow aspect observation apertures and conventional methods …

    bu Repository record for Sparse reconstruction in monostatic and multistatic SAR (opens in a new tab) Embargoed until 2999-01-01

  12. Combined electron imaging and diffraction methods for understanding disordered rocksalt cathodes

    … a digression is taken into optimising the workflow for 4-dimensional scanning transmission electron microscopy (4D-STEM) data, specifically, in the case of low-dose imaging of beam-sensitive materials, including potential cathode candidates.</p> <br> <p>The aforementioned digression into …

    oxford Repository record for Combined electron imaging and diffraction methods for understanding disordered rocksalt cathodes (opens in a new tab)

  13. Capsule Network-based COVID-19 Diagnosis and Transformer-based Lung Cancer Invasiveness Prediction via Computerized Tomography (CT) Images

    … spatial patterns in its images. Furthermore, following the recent and ever-increasing interest in using Low-Dose and Ultra-Low-Dose CT scans (LDCT and ULDCT) for COVID-19 screening, the WSO-CAPS framework is proposed to enhance performance of the proposed models to deal with noisy and low-quality …

    concordia Download PDF for Capsule Network-based COVID-19 Diagnosis and Transformer-based Lung Cancer Invasiveness Prediction via Computerized Tomography (CT) Images (opens in a new tab)

  14. Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy

    <p>Onboard image guidance and dose verification play important roles in radiation therapy, which enables precise targeting and accurate dose delivery. However, clinical utilities of these advanced techniques are limited by their degraded image quality due to the under-sampling. Specifically, …

    duke Repository record for Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy (opens in a new tab)

  15. Die Optimierung von Funktion und Standzeit in der Hüftendoprothetik

    … 3D- Bildgebungsverfahren wie das EOS ultra-low-dose- imaging revolutionieren möglicherweise die chirurgische Planung (engl. templating) einer Prothese [95]. Die konventionelle Planung an einer anterior-posterioren Beckenübersicht wird der Komplexität des Hüftgelenkes nicht gerecht. Die …

    fu-berlin Repository record for Die Optimierung von Funktion und Standzeit in der Hüftendoprothetik (opens in a new tab)

  16. Χρήση αλγορίθμων τεχνητής νοημοσύνης για τη βελτιστοποίηση των εφαρμοζόμενων πρακτικών στην πυρηνική ιατρική

    … evaluate deep learning algorithms for denoising low-dose planar bone scintigraphy images. The main goal is to safely reduce the administered radiotracer activity and/or acquisition time while maintaining the diagnostic reliability of the images, thereby facilitating the practical implementation …

    greece Repository record for Χρήση αλγορίθμων τεχνητής νοημοσύνης για τη βελτιστοποίηση των εφαρμοζόμενων πρακτικών στην πυρηνική ιατρική (opens in a new tab)