Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Lumped-parameter modelling"”

  1. Lumped parameter modelling of two-phase geothermal reservoirs

    … decades have increasingly seen the applying of lumped parameter models (LPM) to geothermal reservoir analysis and production planning. Many studies focused on the simulating performance of low-temperature geothermal reservoirs using the lumped-parameter method. A few works had focused on the …

    reykjavik Repository record for Lumped parameter modelling of two-phase geothermal reservoirs (opens in a new tab)

  2. A lumped parameter modelling method for high-temerature geothermal reservoirs

    … placed on using more simple techniques, such as lumped parameter methods. This is due to the necessity of dealing with temperature effects, and up to date, lumped parameter methods have been mostly limited to models incorporating only pressure changes. Here a method has been developed which …

    akureyri Repository record for A lumped parameter modelling method for high-temerature geothermal reservoirs (opens in a new tab)

  3. Lumped Parameter Modelling of Changes in Liver Hemodynamics due to Cirrhosis

    In this thesis, a lumped parameter hydraulic network model is used to simulate blood flow through the entire human liver to study the effects of cirrhosis on liver hemodynamics. Blood is transported from the hepatic artery and portal vein through the liver via a network of sinusoids, eventually …

    umn Repository record for Lumped Parameter Modelling of Changes in Liver Hemodynamics due to Cirrhosis (opens in a new tab)

  4. Lumped-Parameter Modelling of Cardiovascular System Dynamics under Different Healthy and Diseased Conditions

    … of cardiovascular diseases is an urgent task. Lumped-parameter mathematical modelling as an efficient and effective research technique has been extensively applied in the cardiovascular dynamics research, and has achieved enormous success in assisting the cardiovascular physiology study. This …

    whiterose Repository record for Lumped-Parameter Modelling of Cardiovascular System Dynamics under Different Healthy and Diseased Conditions (opens in a new tab)

  5. Haemodynamic Simulation of Pulmonary Circulation based on Lumped Parameter Modelling and Parameter Inference using CMA-ES

    … of pulmonary circulation, including model parameter inference, by combining structured lumped parameter modelling (LPM) with Covariance Matrix Adaptation Evolution Strategy (CMA-ES). The goal is to build a comprehensive computational tool that enables efficient and physiologically grounded …

    ucl Repository record for Haemodynamic Simulation of Pulmonary Circulation based on Lumped Parameter Modelling and Parameter Inference using CMA-ES (opens in a new tab)

  6. Lumped-parameter modelling of elastically coupled bodies: Derivation of constitutive equations and determination of stiffness matrices

    Modelling of elastically coupled rigid bodies is an important research topic in multibody dynamics. We consider the problem of modelling what can be called flexural joints, where two essentially rigid bodies are coupled by a substantially more elastic body. For modelling general elastic couplings …

    arizona-thes Repository record for Lumped-parameter modelling of elastically coupled bodies: Derivation of constitutive equations and determination of stiffness matrices (opens in a new tab)

  7. Impact of Transcatheter Aortic Valve Replacement on Coronary Hemodynamics using Clinical Measurements and an Image-Based Patient-Specific Lumped Parameter Model

    … in the field of cardiovascular computational modelling to help combat the devastating impact of cardiovascular disease. Lumped parameter modelling (a branch of computational modelling) holds the potential of aiding in the early diagnosis of these diseases, assisting clinicians in determining …

    mcmaster Repository record for Impact of Transcatheter Aortic Valve Replacement on Coronary Hemodynamics using Clinical Measurements and an Image-Based Patient-Specific Lumped Parameter Model (opens in a new tab)

  8. Design of a Multiloop Pyroelectric Neutron Generator Control System

    … have been developed using two control system modelling approaches: lumped-parameter and system identification modelling. Describing equations for the pyroelectric subsystem components are detailed and implemented using lumped-parameter modelling. Novel work towards the analysis of the …

    cambridge Repository record for Design of a Multiloop Pyroelectric Neutron Generator Control System (opens in a new tab)

  9. Development of a low inertia drumless tether management system

    … tow cable in two dimensions was developed using lumped parameter modelling. The model was implemented in Matlab, and simulations were done for different towing speeds. Towing forces including analysis of drag on cable, and relative sensor position under varying towing conditions could be …

    newfoundland Repository record for Development of a low inertia drumless tether management system (opens in a new tab)

  10. Experimental studies on a liquid ultrasonic cylindrical waveguide

    … impedance of the transducer by employing lumped-parameter modelling (under different loading conditions). The operation of the device in its non-linear regime was found to be characterized by a novel capillary instability formation of the cylindrical stream. The capillary instabilities were …

    soton Repository record for Experimental studies on a liquid ultrasonic cylindrical waveguide (opens in a new tab)

  11. The use of static frequency converter feeder stations and a new control strategy enabling mesh feeding for 50 Hz AC railways

    … code written in MATLAB Script. The mathematical modelling of the traction system is based on a lumped parameter modelling approach. These studies show that the application of SFCs requires lower rated feeder stations and provides increased operational flexibility and fault tolerance, while not …

    birmingham Repository record for The use of static frequency converter feeder stations and a new control strategy enabling mesh feeding for 50 Hz AC railways (opens in a new tab)

  12. Thermal front velocity modelling and lumped parameter simulation

    … two results are in good agreement. By Applying lumped parameter modelling to well MN08 in Munadanes in west Iceland, the size of the reservoir, base on an estimated 900 m reservoir depth, the permeability and the storage mechanism of the reservoir intersecting well MN08 are evaluated. Diverse …

    reykjavik Repository record for Thermal front velocity modelling and lumped parameter simulation (opens in a new tab)

  13. New Frank-Starling based contractility and ventricular stiffness indices: clinically applicable alternative to Emax

    … patients at various stages of valve disease. A lumped parameter model of the pumping ventricle was constructed utilizing the basic principles of the Frank-Startling law. The systemic circulation was modeled as a three element windkessel block for the arterial and venous elements. Based on the …

    colostate Repository record for New Frank-Starling based contractility and ventricular stiffness indices: clinically applicable alternative to Emax (opens in a new tab)

  14. Multi-scale computational modeling of coronary blood flow: application to fractional flow reserve.

    … combined with computational coronary flow modelling may reduce the patient’s burden of undergoing invasive testing. Research statement. The ability to obtain information of the hemodynamic significance of detected lesions would streamline decision making in escalation to invasive …

    uwo Repository record for Multi-scale computational modeling of coronary blood flow: application to fractional flow reserve. (opens in a new tab)

  15. Improved methods for characterising acoustoplasticity

    … transducer coincided with a displacement node. Lumped-parameter modelling indicated that the dynamic response of the piezoelectric force transducer’s structure could significantly distort the amplitude of an oscillatory force measurand. Either amplification or attenuation could result depending …

    glasgow Repository record for Improved methods for characterising acoustoplasticity (opens in a new tab)

  16. Nonlinear dynamic interactions between a rigid attachment bolted to a thin-walled sheet metal structure

    … evaluate a model formulation and identify model parameters. The proposed nonlinear stiffness formulation accurately captures observed changes in the system natural frequency and the contact damping formulation reasonably captures the excitation amplitude damping properties. Such analytical models …

    ohiolink Repository record for Nonlinear dynamic interactions between a rigid attachment bolted to a thin-walled sheet metal structure (opens in a new tab)

  17. Modelling Carbon Dioxide Content of a Liquid Dominated Geothermal Reservoir

    … dioxide fluxes were monitored. In this study, a lumped parameter model that can account for carbon dioxide content and soil carbon dioxide fluxes is developed. The developed model relates the soil fluxes to the carbon dioxide content of the reservoir by a parameter (θ). The model developed in …

    metu Repository record for Modelling Carbon Dioxide Content of a Liquid Dominated Geothermal Reservoir (opens in a new tab)

  18. Lumped Power-Balanced Modelling and Simulation of the Vocal Apparatus : a Fluid-Strucutre Interaction Approach

    Cette thèse traite de la modélisation et de la simulation de l'appareil vocal, et notamment du conduit vocal articulé. L'objectif principal est de décrire, de manière concomitante, la propagation des ondes acoustiques et l'écoulement de l'air en interaction avec les tissus des voies aériennes. …

    star-france Repository record for Lumped Power-Balanced Modelling and Simulation of the Vocal Apparatus : a Fluid-Strucutre Interaction Approach (opens in a new tab)

  19. Towards patient-specific modelling as a pre-operative planning strategy and follow up assessment for the treatment of advanced heart failure with rotary blood pumps

    … management; b) to review the theory behind modelling approaches to VADs and their interactions with the cardiovascular system for better understanding of their clinical use. Then, an overview of computational fluid dynamics (CFD) is considered as a prelude to its application to the analysis …

    strathclyde Repository record for Towards patient-specific modelling as a pre-operative planning strategy and follow up assessment for the treatment of advanced heart failure with rotary blood pumps (opens in a new tab)