Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 56 for “"Lung deposition"”
-
Data-Driven Modeling of Lung Deposition of Aerosol Medication Delivered by Metered Dose Inhalers
… their MDI use technique as well as the resulting lung deposition. In this thesis, I have developed and validated a predictive model of lung deposition corresponding to any MDI technique in three phases. Phase I: I conducted the first pilot study that quantitatively measured MDI technique from 23 …
-
Improving Exposure Assessment of Airborne Metals: A Lung Deposition Sampler to Estimate Body Burden of Welding Fume Exposure
… the particle size fraction that penetrates the lungs. However, it is the lung-deposited particle fraction that most contributes to body burden and this deposited dose can differ from penetrative estimates by a factor between two and six. This dissertation proposed to a) evaluate a means for …
-
Filling Research Gaps in Occupational Health in Thermal Spray Coatings: A Scoping Review, Lab Characterization, and Lung Deposition of Cold Sprayed Emissions
… into a usable format that can be inputted into lung deposition software for toxicological interpretation. Together, these chapters offer a comprehensive overview of what is known in the realm of occupational health in TSCs, the first characterization study of CS emissions, and a methodological …
-
Use of track-etched polycarbonate filters in series to mimic the total human lung deposition in the ultrafine and fine particle range from 0.03 to 0.40 microns.
… filter tester to determine the filter assembly’s deposition curve as a function of particle size from 0.03 to 0.4 m. The filter assembly’s efficiency curve was compared to Stahlhofen’s resting with nose breathing and working with mouth breathing human total lung deposition curves used by the ICRP. …
-
Physical properties of particles and their implications for the calculation of the human regional lung dose
… predict the penetration, infiltration factors, deposition and loss rates of indoor particles. The loss rates of indoor particles, which are mainly subject to deposition, coagulation and evaporation, were found to be a function of particle size and time. Moreover, HTDMA measurements were …
-
Charting the human lung with inhaled nanoparticles : Development of AiDA - a new diagnostic technique for respiratory disease
Changes to the smallest structures of the distal lung are often the first sign of severe respiratory disease, but to date methods to detect and quantify these changes are limited. Chronic obstructive pulmonary disease (COPD) is currently estimated to be the third most common cause of death …
-
Relative Bio-Equivalence of Salbutamol MDIs Without and With the Attached Spacers. Development and validation of novel HPLC methods for the determination of salbutamol (and terbutaline) in urine excreted post-inhalation for bioequivalence and pharmacokinetic studies of Salbutamol MDIs
… excretion of salbutamol in the first 0.5 hour (lung deposition, USAL0.5) and over 24 hours (total systemic bioavailability, USAL24) were compared to determine the bioequivalence of the MDIs. The spacers recommended for use with these inhalers were also studied, and charcoal block studies were …
-
Assessing particle deposition in a representative in vitro model of the rat respiratory tract
… to develop an in vitro model (IVR) of the rat lung for the purpose of investigating the deposition of drug particles in the rat airways. The model attempted to account for the affect of drug product characteristics and physiological parameters on deposition in the lungs. In addition, the model …
-
Lipid nanoparticles biocompatibility and cellular uptake in a 3D human lung model
… receptors and assess their uptake in a 3D human lung model. Materials & methods: NLCs and mannosylated-NLCs were synthetized and characterized. Their uptake and biocompatibility were tested in a 3D human lung model. Results: The formulations have appropriate size (170-202 nm) and morphology for …
-
Disproportionate Aerosol Exposures in High Intensity Interval Training Gyms: A Needs Assessment Study
… during high-traffic gym class times. Annual lung deposition estimates indicated substantial exposure to PM1, PM2.5, PM10, and black carbon (BC), posing health risks to gym participants and employees. These findings underscore the need for proprietor education, comprehensive environmental …
-
Development of clinically relevant in vitro performance tests for powder inhalers
… vivo correlations (IVIVCs) and predict in vivo lung doses, the aerodynamic particle size distributions (APSDs) of those doses and their regional lung deposition remains unclear. Four studies were designed to improve testing centered on the behavior of Novolizer®. Different oropharyngeal …
-
Development and optimization of powders containing liposomes for pulmonary administration
… by physiological barriers that hinder drug deposition and therapeutic efficiency. To address this, liposomes have emerged as attractive carriers, enabling the encapsulation of active pharmaceutical ingredients, their protection from degradation and improved bioavailability, although their …
-
Design of exeriment-based optimization of nebulized pulmonary PBAE-siRNA delivery systems
… which were then nebulized to achieve deep lung deposition. For this cause, in a first step the polymer synthesis was optimized and characterized to gain control and understanding of the process. Here, DoE was applied to reduce the number of experiments and resources spent to control the …
-
A Tracheobronchial Specific in vitro Dissolution Test – A Problem Well Filtered is a Problem Half Dissolved
… been widely successful in treating a variety of lung diseases by delivering drugs directly to the site of action. For any therapeutic action to occur, solid drug particles must deposit on the airway surface, dissolve into lung fluid, and be absorbed by the local tissue. Accordingly, the efficacy …
-
Clarithromycin nanocrystals for high-dose inhalation
… require high systemic doses to reach effective lung levels, increasing adverse effects, lowering adherence and fostering resistance. This work developed a high-dose inhalable dry-powder approach to deliver clarithromycin locally. Poorly soluble clarithromycin (BCS II) was converted to …
-
Evolving In Vitro and In Silico Methods for Predicting Performance in Respiratory Drug Delivery Applications
… methods for characterizing respiratory tract deposition and drug disposition. Chapter 3 describes an in vitro study on deposition from commercially available pharmaceutical inhalers in the Alberta Idealized Throat. This mouth-throat geometry has been used to accurately characterize aerosol …
-
Development of dry powder inhalation for biological drug modalities
… to topically deliver therapeutics to the lung. Generally, a particle size range of 1-5 µm is desirable for the lung deposition of drug aerosols. To date, several particle engineering technologies have been developed and successfully applied to micronize powders of small molecule drugs. …
-
Investigation to Identify the Influence of the Surface Energetics of the Dry Powder Formulations of Budesonide and Theophylline on Their Aerodynamic Dose Emission Characteristics.
… of a dry powder inhaler formulation into the lungs, as there must be a sufficient balance of adhesive and cohesive forces to allow optimal lung delivery. In this study, measuring the surface energies of a set of single drug and carrier (budesonide or theophylline with either mannitol or …
-
Development of dry powder Inhaler and nebulised nanoparticles formulations of chrysin for the potential treatment of asthma. Development of dry powder inhaler of chrysin and nebulised nanoemulsion combination of chrysin and budesonide; Evaluating the anti-inflammatory activity of the combination formulation of chrysin and budesonide for asthma
… the sonocrystallised samples were used. As the lung deposition was relatively low, budesonide was not added to the formulations. Next, liquid formulations of chrysin and budesonide were prepared in two concentrations using limonene and oleic acid as the oil phase. In a comparison of low and high …
-
Characterization of Nano and Sub-micron Crystalline Silica Aerosol Generated during Mechanical Processing of Various Construction Materials
… cause pulmonary diseases such as silicosis and lung cancer. The increasing popularity and demand for high crystalline silica containing materials, such as engineered stones, has resulted in a resurgence of silicosis globally. However, little is known about the impact of various sub-fractions of …
Page 1 of 3