Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 224 for “"Lysimeter"”.

  1. Metal distribution in a lysimeter : experimental methods

    … septic tank pumpings were added to six airtight lysimeters and the liquid effluent was monitored for Cd, Cr, Fe, Ni, Pb and Zn releases. The study did not determine specific metal retention mechanisms. Therefore, the study report herein was initiated to establish experimental procedures to …

    ubc Repository record for Metal distribution in a lysimeter : experimental methods (opens in a new tab) Download PDF for Metal distribution in a lysimeter : experimental methods (opens in a new tab)

  2. Design and evaluation of a small weighing lysimeter

    … to design and test a small, 12 inch in diameter, lysimeter to measure evapotranspiration (ET) in the field. An initial lysimeter design using load cells was constructed and tested in a laboratory setting. Temperature tests indicated that this design lacked the sensitivity desired for accurate ET …

    ut-knoxville Repository record for Design and evaluation of a small weighing lysimeter (opens in a new tab)

  3. Design and comparison of a small, monolithic weighing lysimeter to a large lysimeter and to the penman and penman-monteith equations

    … and evaluation of a small, monolithic, weighing lysimeter (<1 m<sup>2</sup>) is described. The small lysimeter is composed of three components: an outer container, a soil column assembly (soil container and soil column), and a weighing mechanism. The circular lysimeter has a surface area of 0.072 …

    ut-knoxville Repository record for Design and comparison of a small, monolithic weighing lysimeter to a large lysimeter and to the penman and penman-monteith equations (opens in a new tab)

  4. Development of a stand-pipe lysimeter for unsaturated waste rock

    … above the local groundwater table. A stand-pipe lysimeter designed to measure suction and collect pore water samples from unsaturated waste rock piles has been developed and verified in a large-scale laboratory test. The laboratory testing of the prototype lysimeter involved the building of two …

    sask Repository record for Development of a stand-pipe lysimeter for unsaturated waste rock (opens in a new tab)

  5. Suction Cup Lysimeter Method for Extracting Pine Bark Substrate Solution

    … to determine the effectiveness of suction cup lysimeters (SCL) in extracting substrate solution from pine bark substrates. Lysimeter types tested were 4.8-cm diameter with a ½ or 1-bar air-entry value (AEV) and 2.2-cm diameter also with a ½ or 1-bar AEV. Sufficient volume could be obtained when …

    vt Repository record for Suction Cup Lysimeter Method for Extracting Pine Bark Substrate Solution (opens in a new tab)

  6. A lysimeter study of domestic waste water renovation by forest soil filtration

    Laboratory lysimeters were used to investigate the behaviour, over time, of a humid west coast forest soil under intermittent primary municipal waste water irrigation. Mineral soil packed to a depth of 69 cm and to a uniform density of about 0.9 gm per cm³ was covered with a forest floor 9 cm …

    ubc Repository record for A lysimeter study of domestic waste water renovation by forest soil filtration (opens in a new tab) Download PDF for A lysimeter study of domestic waste water renovation by forest soil filtration (opens in a new tab)

  7. Quantifying Biocrust Evaporation in Arid Lands by Combining Thermal Imaging and Lysimeter Measurements

    … biocrust patch surrounded by bare soil atop a lysimeter in the Mojave Desert near Las Vegas, Nevada. Using high-resolution thermal imaging, and the known latent heat flux from the lysimeter, I monitored spatial and temporal patterns in surface temperature and applied the three-temperatures (3T) …

    unlv Repository record for Quantifying Biocrust Evaporation in Arid Lands by Combining Thermal Imaging and Lysimeter Measurements (opens in a new tab) Download PDF for Quantifying Biocrust Evaporation in Arid Lands by Combining Thermal Imaging and Lysimeter Measurements (opens in a new tab)

  8. Estimation of evapotranspiration from a bioretention facility using a lysimeter and six predictive equations

    … a significant component of the water balance. A lysimeter study was conducted in Guelph, Ontario to estimate the ET rate from bioretention facilities. The lysimeter was designed to mimic standard bioretention design parameters. The average annual ET rate was 1.30 mm/d, with monthly averages …

    guelph Repository record for Estimation of evapotranspiration from a bioretention facility using a lysimeter and six predictive equations (opens in a new tab)

  9. Water Budgets under Contrasting Winter Warming Conditions: A Lysimeter Study in a Humid Continental Climate

    … with two soil types in monolithic weighing lysimeters. Two winter warming treatments were applied, a continuous warming to inhibit FTCs, and intermittent warming to increase FTCs. We observed that as soil freezing decreased, the amount of water partitioned from storage to drainage increased …

    guelph Repository record for Water Budgets under Contrasting Winter Warming Conditions: A Lysimeter Study in a Humid Continental Climate (opens in a new tab)

  10. Examining Multiple Techniques to Interpolate Discrete Soil Moisture Measurements using a Large-Scale Lysimeter Facility

    … interpolations. This research used a large-scale lysimeter facility to evaluate the accuracy to which a linear interpolation can characterize a soil water profile. Results identified that a linear interpolation can describe the profile with normalized root mean square errors of 4.38% and 4.5% for …

    guelph Repository record for Examining Multiple Techniques to Interpolate Discrete Soil Moisture Measurements using a Large-Scale Lysimeter Facility (opens in a new tab)

  11. Predictive Modeling of Organic Pollutant Leaching and Transport Behavior at the Lysimeter and Field Scales

    … for laboratory scale data, was applied to lysimeter scale data from two research centres, FZJ (Jülich) and GSF (München) for long term predictions. Results from pure forward model runs show a fairly good correlation with the measured data. Finally, the derived source term functions in …

    qucosa-diss

  12. The Weight of Water: Using a Geological Weighing Lysimeter to Quantify the Field-Scale Water Balance

    … and spatial resolutions. Geological Weighing Lysimeters (GWL) are novel instruments that provide measurements of total integrated water storage at scales of 102 m2 and 106 m2 (field-scale). These tools use a saturated formations response to changes in mechanical loading, to estimate the change …

    sask Repository record for The Weight of Water: Using a Geological Weighing Lysimeter to Quantify the Field-Scale Water Balance (opens in a new tab)

  13. Lysimeter measurements of salal understory evapotranspiration and forest soil evaporation after salal removal in a Douglas-fir plantation

    Two weighing lysimeters were constructed in a 23-year-old Douglas-fir (Pseudotsuga menziesii (Mirb.) Franco) stand. The salal (Gaultheria shallon Pursh.) understory was mechanically removed from a 30 x 40 m plot and one lysimeter was located at the center of this plot to measure daily forest soil …

    ubc Repository record for Lysimeter measurements of salal understory evapotranspiration and forest soil evaporation after salal removal in a Douglas-fir plantation (opens in a new tab) Download PDF for Lysimeter measurements of salal understory evapotranspiration and forest soil evaporation after salal removal in a Douglas-fir plantation (opens in a new tab)

  14. Water Balance and Moisture Dynamics of an Arid and Semi-Arid Soil: A Weighing Lysimeter and Field Study

    … and storage of bare, arid soil in weighing lysimeters, (ii) evaluate a process-based evaporation model using evaporation data from the same bare, arid soil, and (iii) monitor the soil moisture and temperature dynamics of a vegetated, semi-arid soil at a field site. The studies were carried …

    unlv Repository record for Water Balance and Moisture Dynamics of an Arid and Semi-Arid Soil: A Weighing Lysimeter and Field Study (opens in a new tab) Download PDF for Water Balance and Moisture Dynamics of an Arid and Semi-Arid Soil: A Weighing Lysimeter and Field Study (opens in a new tab)

  15. Nitrogen Movement and Transformations in Soils as Evaluated by a Lysimeter Study Utilizing Isotopic Nitrogen and a Field Study

    Made available in DSpace on 2014-12-04T20:16:59Z (GMT). No. of bitstreams: 1 5900555.pdf: 4041353 bytes, checksum: a4cb58dff274bd55c44f70e54d719a9a (MD5) Previous issue date: 1958

    uiuc Repository record for Nitrogen Movement and Transformations in Soils as Evaluated by a Lysimeter Study Utilizing Isotopic Nitrogen and a Field Study (opens in a new tab)

  16. Evaluating the ASCE standardized Penman-Monteith equation and developing crop coefficients of alfalfa using a weighing lysimeter in southeast Colorado

    To view the abstract, please see the full text of the document.

    colostate Repository record for Evaluating the ASCE standardized Penman-Monteith equation and developing crop coefficients of alfalfa using a weighing lysimeter in southeast Colorado (opens in a new tab)

  17. Impact of lime application on transport of nitrate-nitrogen, atrazine, and cyanazine to subsurface drainage water: A field lysimeter study

    Development of a durable, tile-drained lysimeter that can easily be installed in a field setting and provide adequate sample collection could significantly improve current methods of groundwater monitoring. Therefore, this study was initiated to: (1) design, construct, and install a field lysimeter …

    iastate Repository record for Impact of lime application on transport of nitrate-nitrogen, atrazine, and cyanazine to subsurface drainage water: A field lysimeter study (opens in a new tab)

  18. Hydraulic evaluation of lysimeters versus actual evapotranspirative caps

    … a soil cover is typically achieved using pan lysimeters which consist of a drainage layer underlain by an impermeable geomembrane liner. The presence of this hydraulic barrier in lysimeter, which is used to facilitate the collection and measurement of percolation, alters the hydraulics of the …

    msu Repository record for Hydraulic evaluation of lysimeters versus actual evapotranspirative caps (opens in a new tab)