Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 250 for “"Lysimeters"”.

  1. Short-Term Water Use Dynamics in Drainage Lysimeters

    … was developed. Pairs of non-weighing drainage lysimeters were used to determine crop coefficients for turfgrass in four locations in the state of Utah: Logan Golf and Country Club, Murray Golf Course, Brigham Young University (Spanish Fork) Experiment Farm, and Sunbrook Golf Course (St. …

    utahstate Repository record for Short-Term Water Use Dynamics in Drainage Lysimeters (opens in a new tab)

  2. Hydraulic evaluation of lysimeters versus actual evapotranspirative caps

    … a soil cover is typically achieved using pan lysimeters which consist of a drainage layer underlain by an impermeable geomembrane liner. The presence of this hydraulic barrier in lysimeter, which is used to facilitate the collection and measurement of percolation, alters the hydraulics of the …

    msu Repository record for Hydraulic evaluation of lysimeters versus actual evapotranspirative caps (opens in a new tab)

  3. Biocell Waste Treatment: Methane Optimization via BMP and Lysimeters

    … lysimeter experiments. Six BMP reactors and six lysimeters were designed to simulate different waste mixtures, including food waste (FW), green waste (GW), dry fraction of municipal solid waste (DMSW), and digested biosolids (DB). Results indicate that BMP assays tend to overestimate methane …

    calgary Repository record for Biocell Waste Treatment: Methane Optimization via BMP and Lysimeters (opens in a new tab)

  4. Evaluation of the performance of soil moisture sensors in laboratory-scale lysimeters

    … sensors were evaluated in laboratory-scale lysimeters. The performances of tensiometers, granular matrix sensors (GMS), capacitance sensors, phase transmission sensors, and of a portable capacitance probe and a frequency-domain reflectometry (FDR) sensor was observed in loam (31.5% sand, …

    manitoba Repository record for Evaluation of the performance of soil moisture sensors in laboratory-scale lysimeters (opens in a new tab)

  5. Testing Sampling Efficiencies of Suction Lysimeters in Laboratory Scale Leaching Bed Systems

    … used widely in rural areas of Canada. Suction lysimeters are popular soil water samplers used in the soil vadose zone that has demonstrated that they can successfully detect chemical containments in leaching bed systems. However, limited research has been made a directly comparison on different …

    guelph Repository record for Testing Sampling Efficiencies of Suction Lysimeters in Laboratory Scale Leaching Bed Systems (opens in a new tab)

  6. Exploration of Evapotranspiration (ET) Sensitivity to Vegetation Indices (VIs) Using Weighing Lysimeters

    … regions to ET. Using a network of large weighing lysimeters we measured and recorded ET and VIs over a summer growing season. Most tested VIs had an insignificant correlation to ET measurements, including LAI which was found to have a weak relationship with the ET measurements (R = 0.529). …

    guelph Repository record for Exploration of Evapotranspiration (ET) Sensitivity to Vegetation Indices (VIs) Using Weighing Lysimeters (opens in a new tab)

  7. Effectiveness of Suction Lysimeters in Determining Contaminant Transport Within Leaching Bed Systems

    … to determine the effectiveness of using suction lysimeters to determine if leaching beds are functioning as intended with respect to chemical contaminants (TKN, nitrate, nitrite) and biological contaminants (Escherichia coli). Results from lab and leaching bed experiments indicate that suction …

    guelph Repository record for Effectiveness of Suction Lysimeters in Determining Contaminant Transport Within Leaching Bed Systems (opens in a new tab)

  8. An Examination of Radionuclide Transport in the Vadose Zone Using Field Lysimeters

    … onto a small mass of the soil used to pack the lysimeters. The second, which was chosen to represent the release from the cementitious waste form at the SRS, was prepared by amending the radionuclides into the pre-mixture batch components of the cementitious material (Roberts et al., 2012). The …

    clemson Repository record for An Examination of Radionuclide Transport in the Vadose Zone Using Field Lysimeters (opens in a new tab)

  9. A study of soils and leachates from two forest sites using tension lysimeters

    … soil factors as to site differentiation. Tension lysimeters with silicon carbide powder, as a contact material, were used to collect water passing through the soils of the two sites at a soil water tension of less than 0.10 bar. As the study was performed on sloping topography, tension lysimeters …

    ubc Repository record for A study of soils and leachates from two forest sites using tension lysimeters (opens in a new tab) Download PDF for A study of soils and leachates from two forest sites using tension lysimeters (opens in a new tab)

  10. Monitoring near-surface soil water loss with time domain reflectometry and weighing lysimeters

    … with a data logger and personal computer. Both lysimeters are instrumented with TDR probes, tensiometers, and pore water solution samplers; thermocouples are installed in one lysimeter for measuring temperature. The TDR probes were calibrated using a transient method known as upward …

    arizona-thes Repository record for Monitoring near-surface soil water loss with time domain reflectometry and weighing lysimeters (opens in a new tab)

  11. Monitoring high water table effects on corn growth and water quality in growth chambers and field lysimeters

    … environmentally controlled chambers and field lysimeters. Four stress levels due to excessive wetness, equivalent to 90, 180, 270 and 360 cm-days (Sieben's SEW[subscript]30 concept), were applied to growing corn by surface flooding for 3, 6, 9, and 12 days, and for 6, 12, 18, and 24 days when …

    iastate Repository record for Monitoring high water table effects on corn growth and water quality in growth chambers and field lysimeters (opens in a new tab)

  12. Quantification of the Spatial Distribution of Radionuclides in Field Lysimeters with a Collimated High-Resolution Gamma-Ray Spectrometer

    … spatial distribution of radionuclides in field lysimeters from the Radionuclide Field Lysimeter Experiment (RadFLEX) facility at the Savannah River Nationals Laboratory (SRNL). The lysimeters, containing 137Cs, 60Co, 133Ba and 152Eu incorporated either into solid wasteforms (Portland cement and …

    clemson Repository record for Quantification of the Spatial Distribution of Radionuclides in Field Lysimeters with a Collimated High-Resolution Gamma-Ray Spectrometer (opens in a new tab)

  13. A lysimeter study of domestic waste water renovation by forest soil filtration

    Laboratory lysimeters were used to investigate the behaviour, over time, of a humid west coast forest soil under intermittent primary municipal waste water irrigation. Mineral soil packed to a depth of 69 cm and to a uniform density of about 0.9 gm per cm³ was covered with a forest floor 9 cm …

    ubc Repository record for A lysimeter study of domestic waste water renovation by forest soil filtration (opens in a new tab) Download PDF for A lysimeter study of domestic waste water renovation by forest soil filtration (opens in a new tab)

  14. Long Term Impacts of a Genetically Engineered Microorganism (GEM) and Polycyclic Aromatic Hydrocarbons (PAHs) on Soil Bacterial Communities

    … was released into PAH-contaminated soil in lysimeters in 1996. Three treatments were imposed: strain HK44 mixed with PAH-contaminated soil (PAH+, HK44+; n=3); strain HK44 mixed with uncontaminated soil (PAH–, HK44+; n=2) and PAH-contaminated soil alone (PAH+, HK44–; n=1). The objective of …

    ut-knoxville Repository record for Long Term Impacts of a Genetically Engineered Microorganism (GEM) and Polycyclic Aromatic Hydrocarbons (PAHs) on Soil Bacterial Communities (opens in a new tab)

  15. Suction Cup Lysimeter Method for Extracting Pine Bark Substrate Solution

    … to determine the effectiveness of suction cup lysimeters (SCL) in extracting substrate solution from pine bark substrates. Lysimeter types tested were 4.8-cm diameter with a ½ or 1-bar air-entry value (AEV) and 2.2-cm diameter also with a ½ or 1-bar AEV. Sufficient volume could be obtained when …

    vt Repository record for Suction Cup Lysimeter Method for Extracting Pine Bark Substrate Solution (opens in a new tab)

Page 1 of 13