Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"MCNP Simulation"”.

  1. Assessment of Monte Carlo N-Particle variance reduction techniques for small solid angle neutron transport

    … measurements were then compared to an analog MCNP simulation of the experimental setup to verify the benchmark MCNP problem was accurate with real world phenomena. Once the analog benchmark was verified, variance reduction methods were included in the MCNP simulation both independently and …

    texas Repository record for Assessment of Monte Carlo N-Particle variance reduction techniques for small solid angle neutron transport (opens in a new tab)

  2. Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT

    … determining the beam intensity profiles. An MCNP simulation is run to score the beam directions; the simulation is run as an adjoint problem to reduce simulation time, with the target as the source and the detectors scoring the dose for the gantry angles of the beam. Then, an optimization …

    gatech Repository record for Evaluation of Beam Angle Scoring Using MCNP and Applied to IMRT (opens in a new tab)

  3. Neural-net-based imager offset estimation in fieldable associated particle imaging

    … detector array. The network was trained using an MCNP simulation of the NMIS system with the neutron array offset in two position and one rotation dimension. The final network was accurate to within 0.49cm, 0.66cm, and 0.66◦ for axial, lateral, and horizontal plane rotations, respectively. Images …

    utk-theses Repository record for Neural-net-based imager offset estimation in fieldable associated particle imaging (opens in a new tab)

  4. Calibration of an irradiation facility

    … Fricke dosimetry (a primary standard). Finally, MCNP modeling was used to simulate irradiation at the various measured points and intermediate points in the radiation field. The results were used to provide dose rates within the radiation field for future researchers, and demonstrated how …

    colostate Repository record for Calibration of an irradiation facility (opens in a new tab)

  5. Simulation of in-core dose rates for an offline CANDU reactor

    … describes the development of a Monte Carlo simulation to predict the dose rates that will be encountered by a novel robotic inspection system for the pressure tubes of an offline CANDU reactor. Simulations were performed using the Monte Carlo N-Particle (MCNP) radiation transport code, …

    uoit Repository record for Simulation of in-core dose rates for an offline CANDU reactor (opens in a new tab)

  6. Save the pangolins! Cobalt-60 as a radioactive deterrent for pangolin preservation

    … injury to the pangolin. Monte Carlo N-Particle (MCNP) simulation and first-principles calculations demonstrated that pangolin scales are thick enough to absorb the maximum energy beta particles emitted as Cobalt-60 decays and the resultant bremsstrahlung is negligible. Placement of 0.01 MBq of …

    colostate Repository record for Save the pangolins! Cobalt-60 as a radioactive deterrent for pangolin preservation (opens in a new tab)

  7. An experimental study of the relative response of plastic scintillators to photons and beta particles within the context of tritium monitoring

    … Ni-63 beta source of maximum energy of 66keV. A simulation was also carried out in MCNP4a to verify the number of H-3 beta particles with max energy 18.6keV that would reach the plastic scintillator in a vacuum setting as well as in an air medium. Scintillator thicknesses ranged from 10μm to …

    uoit Repository record for An experimental study of the relative response of plastic scintillators to photons and beta particles within the context of tritium monitoring (opens in a new tab)

  8. Studies of multiphase distribution and flow in bubble/ slurry bubble columns with /without internals and advanced sustainable construction materials using sophisticated measurement techniques

    … column reactor. Monte Carlo N-Particle (MCNP) simulation has been implemented to simulate the system to generate a large number of calibration points to reconstruct the instantaneous positions of the radioactive particle using the similarity algorithm. The reliable data can help evaluate …

    must-thes Repository record for Studies of multiphase distribution and flow in bubble/ slurry bubble columns with /without internals and advanced sustainable construction materials using sophisticated measurement techniques (opens in a new tab)

  9. Radiation Protection and Health Physics Implications Associated with SMRs for Potential Applications in Turkey

    … reactor facility (or in a public area) using the MCNP Monte Carlo code. In this project, the performance of proposed Small Modular Reactors (SMRs) facilities is evaluated on the basis of radiation protection and applicable regulatory limits. A health physics and radiation protection analysis of …

    tamu Repository record for Radiation Protection and Health Physics Implications Associated with SMRs for Potential Applications in Turkey (opens in a new tab)

  10. Benchmarking of neutron flux parameters at the USGS TRIGA reactor in Lakewood, Colorado

    … addition of two new fuel elements. Therefore, a MCNP software package was used to incorporate the burn up of reactor fuel and to determine the neutron flux at different irradiation locations and at flux monitoring bores. These simulation results were compared with neutron activation analysis …

    colo-mines Repository record for Benchmarking of neutron flux parameters at the USGS TRIGA reactor in Lakewood, Colorado (opens in a new tab)

  11. Design of a Boron Neutron Capture Enhanced Fast Neutron Therapy Assembly

    … using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm2 treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm2 collimation was 21.9% per 100-ppm B-10 for a 5.0-cm tungsten filter and 29.8% …

    gatech Repository record for Design of a Boron Neutron Capture Enhanced Fast Neutron Therapy Assembly (opens in a new tab)

  12. Characterization of modified neutron fields with americium-beryllium and californium-252 sources

    … generated by the Monte Carlo Neutral Particle (MCNP) code. Models were made in MCNP for each of the source and moderating sphere combinations. The neutron fluence and dose rates were tallied during the MCNP simulation. The unfolded experimental data and the MCNP calculations showed good …

    gatech Repository record for Characterization of modified neutron fields with americium-beryllium and californium-252 sources (opens in a new tab)

  13. Energy Harvesting Opportunities Throughout the Nuclear Power Cycle for Self-Powered Wireless Sensor Nodes

    Dedicated sensors are widely used throughout many industries to monitor everyday operations, maintain safety, and report performance characteristics. In order to adopt a more sustainable solution, much research is being applied to self-powered sensing, implementing solutions which harvest wasted …

    vt Repository record for Energy Harvesting Opportunities Throughout the Nuclear Power Cycle for Self-Powered Wireless Sensor Nodes (opens in a new tab)

  14. Možnosti využití thoria v jaderné energetice současnosti

    Výroba elektrické energie z jaderných elektráren pokrývá asi 11 % celosvětové spotřeby. Pro proces štěpení se ve většině reaktorů využívá uranové palivo s různým procentem obohacení štěpného izotopu 235U. Zásoby uranu se snižují a jejich těžební cena roste. Z těchto důvodů je diskutována možnost …

    brno-tech Repository record for Možnosti využití thoria v jaderné energetice současnosti (opens in a new tab)