Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"MCNP5"”.

  1. A neutronic model of the PMR200 prismatic modular reactor using MCNP5

    … using radiation transport and simulation code, MCNP5. The temperature of all the materials is set at 300 K and the pre-conceptual model is found to be supercritical. The reactor is made into a critical configuration by controlling the mass fraction of boron carbide to 4.2% so that the neutron …

    nwu-za Repository record for A neutronic model of the PMR200 prismatic modular reactor using MCNP5 (opens in a new tab)

  2. MCNP5 Criticality Safety Modeling and Validation for LWR Fuel Cycle Applications

    … In this thesis such a validation is done for MCNP5 version 1.51 for criticality calculations for common pressurized water reactor spent fuel storage conditions. This includes systems with soluble boron concentrations up to 3390 ppm and with solid absorbers present. The validation is performed …

    chalmers Repository record for MCNP5 Criticality Safety Modeling and Validation for LWR Fuel Cycle Applications (opens in a new tab)

  3. Nuclear reactor multi-physics simulations with coupled MCNP5 and STAR-CCM+

    The MCNP5 Monte Carlo particle transport code has been coupled to the computational fluid dynamics code, STAR-CCM+, to provide a high fidelity multi-physics simulation tool for analyzing the steady state properties of a PWR core. The codes are executed separately and coupled externally through a …

    uiuc Repository record for Nuclear reactor multi-physics simulations with coupled MCNP5 and STAR-CCM+ (opens in a new tab)

  4. Investigation and improvement of criticality calculations in MCNP5 involving Shannon entropy convergence

    Criticality calculations are often performed in MCNP5 using the Shannon entropy as an indicator of source convergence for the given neutron transport problem. The Shannon entropy is a concept that comes from information theory. The Shannon entropy is calculated for each batch in MCNP5, and it has …

    gatech Repository record for Investigation and improvement of criticality calculations in MCNP5 involving Shannon entropy convergence (opens in a new tab)

  5. Monte Carlo Modeling of a Varian 2100C 18 MV Megavoltage Photon Beam and Subsequent Dose Delivery using MCNP5

    … beam has been modeled in this work using the MCNP5 Monte Carlo particle transport user code. The subsequent beam irradiation was also delivered to a water phantom and benchmarked against experimentally measured depth dose data. The model presented in this work establishes the foundation to …

    gatech Repository record for Monte Carlo Modeling of a Varian 2100C 18 MV Megavoltage Photon Beam and Subsequent Dose Delivery using MCNP5 (opens in a new tab)

  6. The MANE process of generating continuous energy hot-operating temperature cross sections

    … would agree with the cross sections provided by MCNP5. The MANE cross sections were found to be in very good agreement with those provided by MCNP5 with some minor exceptions caused by round-off errors and some differences in the unresolved resonance region. Differences in the resonance region …

    gatech Repository record for The MANE process of generating continuous energy hot-operating temperature cross sections (opens in a new tab)

  7. Development of an electron beam irradiation design for use in the treatment of municipal biosolids and wastewater effluent

    … wastewater effluent. The Monte Carlo N-Particle (MCNP5) radiation transport code was used to simulate the irradiation scenario. Using MCNP5, dual electron-beam sources were modeled as planar surface sources above and below a stainless steel delivery trough containing either effluent water or one …

    tamu Repository record for Development of an electron beam irradiation design for use in the treatment of municipal biosolids and wastewater effluent (opens in a new tab)

  8. Benchmarking of MCNP modelling of HTR cores against experimental data from the astra critical facility

    … The Monte Carlo n-particle transport code MCNP5 was used to perform all the analyses reported in this work. The findings of this thesis indicate that considering the experimental tasks analysed for the ASTRA critical facility Configuration No. 1 using our MCNP5 consideration (code, …

    nwu-za Repository record for Benchmarking of MCNP modelling of HTR cores against experimental data from the astra critical facility (opens in a new tab)

  9. Δοσιμετρία ασθενών κατά τις επεμβατικές ακτινολογικές εξετάσεις με τη χρήση λογισμικού προσομοίωσης Monte Carlo

    … Carlo codes. The used Monte Carlo codes were MCNP5 and PCXMC2.0. There were used two codes in order to increase the accuracy of the calculations.The mean DAP values of the male (n=20) and female (n=23) group that underwent in PTC were 4500±2600 και 5500±3300 cGycm2, respectively. The effective …

    greece Repository record for Δοσιμετρία ασθενών κατά τις επεμβατικές ακτινολογικές εξετάσεις με τη χρήση λογισμικού προσομοίωσης Monte Carlo (opens in a new tab)

  10. Benchmark criticality calculations for one speed neutron transport

    … described above, the standard Monte Carlo code, (MCNP5) has been verified against our results for the case of a critical sphere. Converged keff [eff is subscripted] and neutron density values using MCNP5 are compared with our suggested benchmark values from DO method. It is found that the neutron …

    missouri Repository record for Benchmark criticality calculations for one speed neutron transport (opens in a new tab)

  11. A Methodology for Establishing Zones of Acceptable CAAS Coverage for a New Storage Facility Utilizing MCNP 5 in Adjoint

    … Los Alamos’ Monte Carlo N-Particle Code 5 (MCNP5) in multigroup Adjoint. Validation of the methodology was shown in the comparison of benchmark calculations with empirical results of Sandia testing and with hand calculations utilizing ANS 8.3. Demonstration involved the determination of …

    ut-knoxville Repository record for A Methodology for Establishing Zones of Acceptable CAAS Coverage for a New Storage Facility Utilizing MCNP 5 in Adjoint (opens in a new tab)

  12. Update to ANSI/ANS-6.4.3-1991 for low-Z and compound materials and review of particle transport theory

    … library data in Monte Carlo N Particle 5 (MCNP5) version 1.40. Another code, Anisotropic Source-Flux Iteration Technique (ASFIT), was used as a benchmarking tool to validate the MCNP5 results. The results from MCNP5 did vary from those of the ANS Standard with the greatest differences for …

    unlv Repository record for Update to ANSI/ANS-6.4.3-1991 for low-Z and compound materials and review of particle transport theory (opens in a new tab) Download PDF for Update to ANSI/ANS-6.4.3-1991 for low-Z and compound materials and review of particle transport theory (opens in a new tab)

  13. Quantification of absorbed doses from radioactive gold nanoparticles and chromium 51 seed implants

    … for Au198, Au199 and Cr51 is presented using MCNP5 code from the Monte Carlo Techniques of Oak Ridge National Labs. In the outcome of quantification, it was estimated that large amount of radiation doses in therapeutic range was deposited by the beta radiation of Au198 and Au199. In the other …

    missouri Repository record for Quantification of absorbed doses from radioactive gold nanoparticles and chromium 51 seed implants (opens in a new tab)

  14. Evaluation d'un système de planification pour un traitement de brachythérapie gynécologique en utilisant des techniques Monte Carlo et des mesures expérimentales

    … (TPS) PLATO v14.3 así como el programa MCNP5 basado en el método Monte Carlo, para lo cual se ha desarrollado un modelo del conjunto fuente, aplicador y maniquí. Los TPS no tienen en cuenta la atenuación en los materiales que constituyen el aplicador; por lo que es importante conocer la …

    upv Repository record for Evaluation d'un système de planification pour un traitement de brachythérapie gynécologique en utilisant des techniques Monte Carlo et des mesures expérimentales (opens in a new tab)

  15. Monte Carlo neutronic simulations for a new approach to parametric INAA and Mo-99 production feasibility at MURR

    … has been established. In particular, a detailed MCNP5 steady-state model of the MURR core was developed. The model, which was based on the most recent continuous-energy neutron data from the ENDF and JEFF neutron libraries, was used to compute the local continuous-energy neutron flux …

    missouri Repository record for Monte Carlo neutronic simulations for a new approach to parametric INAA and Mo-99 production feasibility at MURR (opens in a new tab)

  16. Neutronic and thermal hydraulic analysis of the geological survey TRIGA reactor

    … validated a Monte Carlo N-Particle Version 5 (MCNP5) model of the GSTR reactor. The model provided estimates of the excess reactivity, power distribution and the fuel temperature, water temperature, void, and power reactivity coefficients for the current and limiting core. The MCNP5 model …

    colo-mines Repository record for Neutronic and thermal hydraulic analysis of the geological survey TRIGA reactor (opens in a new tab)

  17. Neutronic simulation of a European Pressurised Reactor

    … Reactor (EPR) using Monte-Carlo N-Particle (MCNP5). The neutronic model will in due course be coupled to a thermal hydraulic model forming part of a broader study of the system. The Monte Carlo neutron transport code MCNP5 has been widely used since the 1950s for analysis of existing and …

    nwu-za Repository record for Neutronic simulation of a European Pressurised Reactor (opens in a new tab)

  18. A scoping analysis of the neotronic design for a new South African research reactor

    … by utilizing the OSCAR-4 code collection and MCNP5. Two additional software applications, called KNERSIS and MAAS, were developed: one for the automation of the MGRAC code (part of OSCAR-4); and the other for the interface of data between MGRAC and MCNP5. With this collection of software, a …

    nwu-za Repository record for A scoping analysis of the neotronic design for a new South African research reactor (opens in a new tab)

  19. Pulse height tally response expansion method for application in detector problems

    … that the method is several orders faster than MCNP5 while maintaining paralleled accuracy.

    gatech Repository record for Pulse height tally response expansion method for application in detector problems (opens in a new tab)

  20. Criticality alarm system design guide with accompanying alarm system development for the Radiochemical Processing Laboratory in Richland, Washington

    … analysis for RPL utilized the Monte Carlo code MCNP5 for establishing detector coverage in the facility. Based on the design methodology, significant improvements to the existing CAS were made that increase the reliability, transparency, and coverage of the system.

    unm Repository record for Criticality alarm system design guide with accompanying alarm system development for the Radiochemical Processing Laboratory in Richland, Washington (opens in a new tab)

Page 1 of 4