Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 106 for “"MCNPX"”.
-
Benchmarking photoneutron production of Mcnpx simulations with experimental results
… accelerator to a subcritical reactor assembly. MCNPX, a radiation transport code developed at the Los Alamos National Laboratory, was used in this study. The MCNPX predictions of photo-neutron production were compared with experimental results performed at Idaho Accelerator Centre (IAC), and …
-
Using MCNPX to calculate primary and secondary dose in proton therapy
… designed. Dose calculations were performed by MCNPX using a simple water phantom, and then beam characteristics were investigated to ensure the accuracy of the model. After validation of the beam nozzle, primary and secondary dose values were tabulated and discussed. By demonstrating the method …
-
A comparison of nuclide production and depletion using MCNPX and ORIGEN-ARP reactor models and a sensitivity study of reactor design parameters using MCNPX for nuclear forensics purposes
… of its probabilistic radiation transport code, MCNPX 2.6.0, which incorporates a fuel burnup feature which can also determine, via the probabilistic Monte Carlo method, nuclide concentrations as a function of fuel burnup. This dissertation compares the concentrations of 46 nuclides significant …
-
Proton dose assessment to the human eye using Monte Carlo n-particle transport code (MCNPX)
… of this project was to develop a simple MCNPX model of the human eye to approximate dose delivered from proton therapy. The calculated dose included that due to proton interactions and secondary interactions, which included multiple coulombic energy scattering, elastic and inelastic …
-
Prediction of proton and neutron absorbed-dose distributions in proton beam radiation therapy using Monte Carlo n-particle transport code (MCNPX)
… of this research was to develop a complex MCNPX model of the human head to predict absorbed dose distributions during proton therapy of ocular tumors. Absorbed dose distributions using the complex geometry were compared to a simple MCNPX model of the human eye developed by Oertli. The …
-
Transient behavior of a nuclear reactor coupled to an accelerator
… coupled to an accelerator. It was based on MCNPX, a radiation transport code developed at the LANL, and upon a numerical model of the neutron transport equation. MCNPX was used to generate the neutron "source" term that occurs when the accelerator is fired. ADSTRANS coupled MCNPX to a …
-
Design and Simulation of a Passive-Scattering Nozzle in Proton Beam Radiotherapy
… system in proton beam radiotherapy. MCNPX is a general-purpose Monte Carlo radiation transport code. In this research, we used the NEU codes package to design a passive double-scattering system, and we used MCNPX to simulate the transport of protons in the nozzle and a water phantom. …
-
Update to ANSI/ANS-643-1991 for high-Z materials and review of particle transport theory
… photo-atomic cross-section library data in MCNPX. The results from MCNPX were relatively in good agreement with those of ANSI/ANS-6.4.3-1991, which were calculated using PALLAS-1D (VII). A sample problem was run in both MCNPX and PALLAS and the results were in good agreement. New buildup …
-
Deconvoluting an Americium-Beryllium Neutron Spectrum from a Proton Recoil Detector
… the response functions were calculated using MCNPX. In addition, the detector response to several different 241AmBe neutron spectra were calculated and compared to the experimental data. Using MCNPX, the detector response was able to be modeled. Unfolding the experimental data was not …
-
Development of a portable neutron coincidence counter for field measurements of nuclear materials using the advanced multiplicity capabilities of MCNPX 2.5.F and the neutron coincidence point model
… samples to the calculated output produced using MCNPX and the Neutron Coincidence Point Model. Based on the analysis, it is evident that this new portable system can play a useful role in identifying nuclear material for verification purposes.
-
Thermal Neutron Characterization and Dose Modeling of a Plutonium-239/Beryllium Alpha-Neutron Source
… source and model the neutron dose using version MCNPX of the Monte-Carlo N-Particle transport codes. The 37 GBq 239PuBe alpha-neutron source was placed in a neutron “howitzer,” that is, a 2-ft diameter moderating barrel with four radial irradiation ports. Multi-foil activation was used at various …
-
Neutron flux and energy characterization of a plutonium-beryllium isotopic neutron source by Monte Carlo simulation with verification by neutron activation analysis
… This was accomplished through the use of the MCNPX/5 Monte-Carlo particle transport code to simulate radiation interactions within the physical environment of the source and its surroundings. The moderating drum currently containing the source as well as all of the sampling ports were …
-
A broad spectrum neutron spectrometer utilizing a high energy Bonner sphere extension
… because the response functions are not unique. MCNPX was used to investigate several modifications to the BSS system which resulted in the Bonner Sphere Extension (BSE). This cost effective extension uses several concentric spheres of copper, lead, and tungsten heavy metal downscatter materials …
-
Efficiency modeling for neutron detectors
… varying environmental conditions. Using MCNP/MCNPX the neutron fluence rate and dose rate were evaluated during open-field deployment as a function of moisture content in air and soil, barometric pressure, and varying pavement and soil composition. The focus of this analysis was on the …
-
Novel techniques for the detection and localization of attenuated gamma-ray sources
… Alamos Monte Carlo N-Particle transport code (MCNPX) for detector efficiency calculations. As a necessary supplement to the process, a program was written to automate all MCNPX simulations by modifying input cards and recording the results for all required scenarios. In this work, simulated …
-
PET/CT shielding design comparisons
… through existing lead walls. The computer code MCNPX was used to simulate the leaded walls of the PET/CT suite and provide another set of results. These two sets of results were compared to doses gathered from OSL badges placed around the suite for a period of two months. For this type of …
-
Multivariate Optimization of Neutron Detectors Through Modeling
… of Monte Carlo radiation transport code (MCNPX) models. The developed methodology allows the simultaneous optimization of multiple detector parameters with respect to multiple response parameters which measure the overall performance of a candidate neutron detector. This is achieved by …
-
Development of Self-Interrogation Neutron Resonance Densitometry (SINRD) to Measure the Fissile Content in Nuclear Fuel
… The Monte Carlo Neutral Particle eXtended (MCNPX) transport code was used to simulate SINRD for different geometries. Experimental measurements were also performed with SINRD and were compared to MCNPX simulations of the experiment to verify the accuracy of the MCNPX model of SINRD. Based on …
-
Detector Photon Response and Absorbed Dose and Their Applications to Rapid Triage Techniques
… anthropomorphic phantom was created for use in MCNPX simulations that would provide organ doses from internally deposited radionuclides. Ludlum model 44-9 and 44-2 detectors were used to verify the simulated dose from the MCNPX code. Based on the results, acute dose rate limits were developed …
-
Feasibility Study of a Portable Coupled 3He Detector with LaBr3 Gamma Scintillator for Field Identification and Quantification of Nuclear Material
… In this work, a Monte Carlo Neutral Practicle X (MCNPX) model was used to design an instrument that includes four gamma detection slabs placed within four neutron detection slabs. The combination of gamma spectroscopy and neutron coincidence counting in a single instrument allows for direct …
Page 1 of 6