Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"MCP-PMT"”.

  1. A Multi-Channel MCP-PMT Based Readout Integrated Circuit for LiDAR Applications

    … counting readout circuit that can interface with MCP-PMTs for high dynamic range, space-based LiDAR applications. Chapter 2 presents the conventional current mode approach that has been employed to realize a photon counting circuit. A transimpedance amplifier, a 6-bit delay line based time to …

    unlv Repository record for A Multi-Channel MCP-PMT Based Readout Integrated Circuit for LiDAR Applications (opens in a new tab) Download PDF for A Multi-Channel MCP-PMT Based Readout Integrated Circuit for LiDAR Applications (opens in a new tab)

  2. Data Processing Electronics for an Ultra-Fast Single-Photon Counting Camera

    … built on an FPGA for a microchannel plate (MCP)-photomultiplier tube (PMT) based single-photon counting camera. Each photon is converted by the MCP-PMT into an electron cloud that generates current pulses across a 50×50 cross-strip anode. The Data Processing FPGA executes a massively …

    wustl Repository record for Data Processing Electronics for an Ultra-Fast Single-Photon Counting Camera (opens in a new tab)

  3. DEVELOPMENT OF AN ACOUSTO-OPTIC TUNABLE FILTER BASED TIME-DOMAIN FLUORESCENCE SPECTROMETER WITH HIGH SCANNING SPEED AND HIGH THROUGHPUT FOR OPTICAL BIOPSY APPLICATIONS

    … a gated multichannel plate photomultiplier tube (MCP-PMT), a picosecond Nd:YAG pulsed laser, a digital oscilloscope with high sampling rate and a bifurcated fiber optic probe for light delivery and collection. Typically low throughput of the AOTF was enhanced by collecting both first order …

    mcmaster Repository record for DEVELOPMENT OF AN ACOUSTO-OPTIC TUNABLE FILTER BASED TIME-DOMAIN FLUORESCENCE SPECTROMETER WITH HIGH SCANNING SPEED AND HIGH THROUGHPUT FOR OPTICAL BIOPSY APPLICATIONS (opens in a new tab)

  4. Development of a Time Resolved Fluorescence Spectroscopy System for Near Real-Time Clinical Diagnostic Applications

    … of a dual grating spectrograph coupled with an MCP-PMT. The nitrogen laser also has a dye module attached to it, which enables broadband excitation of the sample. This setup allows rapid acquisition (250 ms for fluorescence decay at a wavelength) of time resolved fluorescence data with a high …

    tamu Repository record for Development of a Time Resolved Fluorescence Spectroscopy System for Near Real-Time Clinical Diagnostic Applications (opens in a new tab)

  5. Towards Quantitative Diagnostics using Short-Pulse Laser Techniques

    … fast detection systems, such as streak cameras, MCP-PMT, where used to demonstrate and develop picosecond LIDAR (LIght Detection And Ranging). Such a scheme allows single ended measurements in case of limited optical access, which most often is the case in practical applications.

    lund Repository record for Towards Quantitative Diagnostics using Short-Pulse Laser Techniques (opens in a new tab) Download PDF for Towards Quantitative Diagnostics using Short-Pulse Laser Techniques (opens in a new tab)

  6. Searches for B → Dμ+μ− decays and test-beam studies of TORCH detector prototypes

    … to the LHCb benchmark is seen, however with MCP-PMT photon detectors of improved quantum efficiency, photon yields close to requirement should be anticipated.</p>

    oxford Repository record for Searches for B → Dμ+μ− decays and test-beam studies of TORCH detector prototypes (opens in a new tab)

  7. Akviziční systém pro LHC Abort Gap Monitor

    Beam Dump Systém velkého hadronového urychlovače LHC je jedním z jeho kritických systémů. Ten se stará o odvedení urychlovaného svazku z~prostoru urychlovače do míst, kde je absorbován. Pro jeho funkci využívá takzvaný Abort Gap - prázdné místo ve svazku bez částic. Toto místo vznikne při …

    brno-tech Repository record for Akviziční systém pro LHC Abort Gap Monitor (opens in a new tab)