Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 139 for “"MICROMOTION"”

  1. Interface micromotion in cementless hip prostheses.

    … Analysis, various factors that could affect micromotion and could compromise the stability of cementless femoral stems. We propose a novel technique for predicting hip stem instability to analyse these problems. The designs of cementless hip stems are crucial to its success. We first …

    ucl Repository record for Interface micromotion in cementless hip prostheses. (opens in a new tab)

  2. Micromotion in Trapped Atom-ion Systems

    … This is equivalent to studying the effect of the micromotion since this motion must be neglected for the trapped ion to be considered as a harmonic oscillator. By applying the transformation of Cook \emph{et al.} we find that the micromotion can be represented by two periodically oscillating …

    nus Repository record for Micromotion in Trapped Atom-ion Systems (opens in a new tab)

  3. Glenoid Baseplate Micromotion in Reverse Total Shoulder Arthroplasty

    Each year approximately 40,000 reverse total shoulder arthroplasties (RTSA) are performed in the United States. This value is increasing annually due to the aging population and increasing indications for the procedure. The most common indication for RTSA is an irreparable rotator cuff where …

    clemson Repository record for Glenoid Baseplate Micromotion in Reverse Total Shoulder Arthroplasty (opens in a new tab)

  4. Cementless Tibial Base Micromotion During Activities of Daily Living

    … activities of daily living generate tibial micromotion yields insight into surgical technique considerations, and rehabilitation strategies post-operatively. ASTM F3141-15, which specifies knee flexion, Internal-External moment, Medial-Lateral, Anterior-Posterior and Superior-Inferior forces …

    denver Repository record for Cementless Tibial Base Micromotion During Activities of Daily Living (opens in a new tab)

  5. Sensitive, 3D micromotion compensation in a surface-electrode ion trap

    … in a fast, driven motion of the ion (known as micromotion) which hinders quantum operations by broadening transitions and causing decoherence. In a surface trap, micromotion detection is difficult as the laser beams used for measurement typically cannot crash into the trap, obscuring ion …

    mit Repository record for Sensitive, 3D micromotion compensation in a surface-electrode ion trap (opens in a new tab)

  6. Effect of Micromotion on Morphogen Dynamics in Peri-Implant Healing

    … Implant loading indeed induces local micromotion at the bone-implant interface, generating strain within the peri-implant tissue. Evidence indicates that the cells involved in the apposition of bone around the implant are mechano-sensitive. To eventually reduce the failure rate of such …

    epfl Repository record for Effect of Micromotion on Morphogen Dynamics in Peri-Implant Healing (opens in a new tab)

  7. Probing Micromotion in a Multi-Segmented Blade-Style Ion Trap

    … electronics control and ion heating caused by micromotion. Blade-style traps are traditionally hand assembled, and therefore are prone to misalignment, leading to increased levels of micromotion. This limitation causes many adverse effects, all negatively contributing to the quality of the …

    waterloo Repository record for Probing Micromotion in a Multi-Segmented Blade-Style Ion Trap (opens in a new tab)

  8. Wear, Corrosion, And Micromotion In Retrieval And Autopsy Components Of Tkr

    … the relationships of wear, corrosion, and micromotion as it relates to aseptic loosening in TKR. 17 TKR devices harvested at revision surgeries and 6 necropsy devices available through UAB’s retrieval program were scored for wear and inflammatory cell-induced corrosion (ICIC). All devices …

    uab Repository record for Wear, Corrosion, And Micromotion In Retrieval And Autopsy Components Of Tkr (opens in a new tab)

  9. Fast entangling gates enabled by micromotion in trapped-ion quantum processors

    … design has historically neglected the RF-driven micromotion intrinsically experienced by trapped ions. While this is appropriate for few-ion systems, implementing fast gates in scalable QC architectures will require that micromotion is incorporated into fast gate design. This thesis accordingly …

    anu Repository record for Fast entangling gates enabled by micromotion in trapped-ion quantum processors (opens in a new tab)

  10. Micromotion derived fluid shear stress mediates perielectrode gliosis through mechanosensitive ion channels

    … and can subject local soft-tissues to micromotion induced mechanical shear, leading to the development of peri-implant scarring. This reactive glial tissue creates a physical barrier to electrical signal propagation, which can lead to loss of device function. Although peri-electrode …

    galway Repository record for Micromotion derived fluid shear stress mediates perielectrode gliosis through mechanosensitive ion channels (opens in a new tab)

  11. Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns

    … The objective of this study was to compare micromotion and kinematic patterns of two TAA designs. Methods: A mechanical simulator was designed to apply compressive loads and bending moments to human cadaveric ankles, intact and replaced. It induced a maximal range of motion in the ankle …

    ubc Repository record for Biomechanical comparison of two total ankle replacement designs : micromotion and kinematic patterns (opens in a new tab)

  12. Micromotion and fluid flow around cementless femoral components in total hip arthroplasty

    … to be critical. In particular, both excessive micromotion and fluid flow at the bone-implant interface during early peri-implant healing have been related to aseptic loosening. In this thesis, micromotion was measured *in vitro* and fluid flow was predicted from measured micromotion using …

    epfl Repository record for Micromotion and fluid flow around cementless femoral components in total hip arthroplasty (opens in a new tab)

  13. Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee

    … of this thesis was to compare the amount of micromotion seen in the femoral stem in a revision total hip arthroplasty between simple loading conditions and loading conditions derived from activities of daily living, through the use of experimental and computational methods. The amount of …

    denver Repository record for Revision Total Hip Femoral Stem Micromotion and Statistical Shape Modeling of the Knee (opens in a new tab)

  14. Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components

    … interface. To promote bone ingrowth, low micromotion between the bone and implant of 20 µm to 50 µm is required. Due to the lack of standard micromotion tests for TAA tibial components, the current study aimed to develop a mechanical test to measure the maximum micromotion at the bone …

    queens Repository record for Design of a Bone-Implant Micromotion Test for Total Ankle Arthroplasty Tibial Components (opens in a new tab)

  15. The micromotion between the polyethylene insert and the tibial tray in total knee prostheses

    Aseptic loosening is the primary means of failure of total knee replacements. Recent studies have suggested a causal relationship between polyethylene (PE) wear debris and aseptic loosening. A few retrieval studies of failed implants have indicated significant back surface wear, but attempts to …

    ohiolink Repository record for The micromotion between the polyethylene insert and the tibial tray in total knee prostheses (opens in a new tab)

  16. Examination of Micromotion-Induced Transient Effects of Brain Tissue Interfaced with A Neural Probe

    … period in vivo, which could be related to micromotion-related strain between the probe and surrounding tissue. A series of finite element analyses were conducted using the nonlinear transient dynamic code LSDYNA (LSTC, Livermore, CA) to study the strain induced within the brain in an area …

    odu Repository record for Examination of Micromotion-Induced Transient Effects of Brain Tissue Interfaced with A Neural Probe (opens in a new tab)

  17. Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty

    … implant configurations that may decrease micromotion and reduce the risk of loosening. Delta XTEND™ baseplates (DePuy Synthes) were implanted into Sawbones™ polyurethane foam blocks (N = 40) and varied in terms of their method of central fixation (screw vs. peg), central length (13.5 vs. …

    queens Repository record for Central Fixation Element Type and Size Affect Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty (opens in a new tab)

  18. Vacuum assembly, atomic source development, and micromotion studies for a trapped Ba+ based quantum processor

    … ion trap systems. Finally, excess micromotion, caused by stray electric fields in RF traps, can lead to undesirable effects such as heating and frequency modulation of atomic transitions. This work evaluates the micromotion compensation capabilities of the Phoenix ion trap used in …

    waterloo Repository record for Vacuum assembly, atomic source development, and micromotion studies for a trapped Ba+ based quantum processor (opens in a new tab)

Page 1 of 7