Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 16 of 16 for “"MR guidance"”
-
ANATOMY-GUIDED ULTRASOUND FOR THE EXTENDED FOCUSED ASSESSMENT WITH SONOGRAPHY IN TRAUMA: DEVELOPMENT AND EVALUATION OF A PORTABLE GUIDANCE SYSTEM
… anatomical modeling with mixed reality (MR) visualization to assist novice operators in acquiring diagnostically relevant eFAST views. To address these constraints, ultrasound was combined with predictive anatomical models derived from external anthropometry. A statistical shape atlas of …
-
MR-Guided Cardiac Ablation and Lesion Assessment for Ventricular Arrhythmia Management
… are limited. In this thesis, magnetic resonance (MR) imaging is used to address these challenges by evaluating the spatial extent and characteristics of RF ablation lesions. The first study aimed to comprehensively describe the composition and evolution of acute left ventricular (LV) RF lesions …
-
Immersive Medical Practice and Clinical Training: Virtual and Mixed Reality in Pharmacy and Orthopedic Surgery
… virtual reality (VR) and mixed reality (MR) offer new ways to improve training and surgical precision. This thesis evaluates their educational and clinical impact through two complementary studies. Specific Aim 1 compared an immersive 360° video VR module with conventional training for …
-
MR-based treatment planning for proton therapy
Magnetic resonance imaging for image guidance of proton therapy could greatly reduce dosimetric uncertainties during treatment, as uncertainties due to set-up or anatomical changes can be detected and corrected for. For dose calculation, however, MR images lack information on the stopping power of …
-
Sensors and System Integration for Magnetic Resonance Image (MRI)-Guided and Robot-Assisted Interventions
Demand for magnetic resonance image (MRI)-guided interventions and robot-assisted surgeries continues to increase in the field of medical robotics. MRI-guided interventions provide pre-/intra-operative MR images and intraoperative manipulations. Robot-assisted surgeries guarantee higher safety and …
-
Stochastic Data Assimilation Approaches For Magnetic Resonance Temperature Imaging
During magnetic resonance (MR)-guided thermal therapies, proton resonance frequency shift (PRFS) based MR temperature imaging can quantitatively monitor tissue temperature changes. It is widely known that the PRFS technique is easily perturbed by tissue motion, tissue susceptibility changes, …
-
Surrogate-driven respiratory motion models for MRI-guided lung radiotherapy treatments
An MR-Linac integrates an MR scanner with a radiotherapy delivery system, providing non-ionizing real-time imaging of the internal anatomy before, during and after radiotherapy treatments. Due to spatio-temporal limitations of MR imaging, only high-resolution 2D cine-MR images can be acquired in …
-
The Use Cardiac Magnetic Resonance Imaging Techniques in the Management of Atrial Arrhythmias
… The use of cardiac magnetic resonance (CMR) imaging in the performance of cardiac electrophysiological procedures has grown rapidly over the past decade. This thesis focuses on three main strands regarding the integration of CMR techniques within the management of atrial arrhythmias: …
-
Augmented reality guidance for robot-assisted laparoscopic surgery
… and tumors, using Augmented/Mixed Reality (AR/MR) technology, utilizing imaging data such as, magnetic resonance imaging and ultrasound (US). The successful intra-operative AR/MR depends on primarily two things. First, the surgically compatible calibration steps, to map the imaging data …
-
Real-time mri in two orthogonal slices for therapy monitoring and interventional guidance
MRI guidance can enhance lesion detection and procedural accuracy during therapeutic interventions. Commonly, fast T1-weighted or T2/T1-weighted gradient echo sequences are used for MR guidance due to their high temporal resolution; however, T2-weighting can provide enhanced tumor visualization. …
-
Flat, Electronically Steered λ/2-Spaced Phased Arrays for Focused Ultrasound Surgery
… for physiological reasons, and rely on expensive MR-guidance. This thesis describes the development of a new type of focused ultrasound therapy array designed to reduce treatment time consisting of elements with half-wavelength spacing arranged in a flat array. Using simulations, this thesis will …
-
A Heterogeneous and Multi-Range Soft-Tissue Deformation Model for Applications in Adaptive Radiotherapy
… deformation models are required. With upcoming MR-guidance, the soft-tissue deformations gain visibility, but so far only few soft-tissue models meeting the requirements of high-precision radiotherapy exist. Most state-of-the-art models either lack anatomical detail or exhibit long computation …
-
Magnetic Resonance Guided Nasojejunal Feeding Tube Placement for Neonates
… correct placement of NJ tubes, but fluoroscopic guidance is the only real-time visualization methodology used clinically. Fluoroscopic placements are limited by the lack of soft tissue contrast and the exposure of the neonate to ionizing radiation. Frequently, NJ feeding tubes are displaced due …
-
In vitro and in vivo investigation of enzymatic clot lysis through non-thermal mechanisms using focused ultrasound waves as an adjunct to thrombolytic drug tenecteplase and in synergy with microbubbles
… invasive), for treating ischaemic stroke under MR guidance. To study the effect of US on thrombolysis efficacy, three different in vitro circulating flow clot models were developed. Fully retracted porcine blood clots were treated with US waves as an adjunct to thrombolytic drug tenecteplase …
-
Inter- and Intrafraction Motion Management for MR guided Proton Therapy of Pancreatic Carcinoma
… Aufgrund des hohen Weichgewebskontrastes in der MRT und der Möglichkeit der Echtzeitbildgebung gewinnt die Unterstützung der Strahlentherapie durch die MRT stetig höheres Interesse. In der Translation von konventioneller Röntgen-geführter XT zur MR-geführten PT müssen Methoden zur Kontrolle der …
-
Development of the Sustained Release Analgesic Formulations for Rodents and a Novel In Vitro Model for Parenteral Formulations with the Character of a Level A IVIVC
… follow the same principles as modified release (MR) oral products. The principles of FDA IVIVC MR guidance for oral products were used to develop and validate level A IVIVC for parenterals in this study. In order to develop sustained release analgesic formulations, nine hydrophobic vehicles, …