Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 122 for “"MR signal"”
-
Beyond the noise : high fidelity MR signal processing
… of liquid state nuclear magnetic resonance (NMR) experiments. NMR is known as one of the most versatile non-invasive analytical techniques yet often suffers from low sensitivity. The main contribution to this low sensitivity issue is a presence of noise and level of noise in the spectrum is …
-
On Nature of the Gradient Echo MR Signal and Its Application to Monitoring Multiple Sclerosis
… a non-invasive tool, Magnetic resonance imaging: MRI) plays a key role in MS diagnosis. Numerous MRI techniques have been proposed over the years. Among most widely used are conventional T1-weighted: T1W), T2-weighted: T2W) and FLuid Attenuated Inversion Recovery: FLAIR) imaging techniques. …
-
Design and development of a deformable and flow compliant aneurysm model for MRI experimentation: effects of turbulence in the MR signal at 3T using a phase contrast-quantitative flow MR protocol.
Cerebral aneurysms are pathological dilations or weakened bulges of the vasculature in the brain. Screening patients with a family history of aneurysms is common, but adds to the healthcare burden. Researchers estimate that unruptured aneurysms affect about 5% of the population. Aneurysm ruptures …
-
Overhauser DNP probes for compact magnetic resonance
… and probe heads for magnetic resonance (MR) spectroscopy and relaxometry. In combina- tion with dynamic nuclear polarization (DNP), high MR signal enhancements are achieved, enabling the analysis of very low amounts of liquid sample.<br>Nuclear magnetic resonance (NMR) is a powerful, …
-
Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System
Diffusion Magnetic Resonance Imaging (DMRI) is a class of Magnetic Resonance Imaging (MRI) techniques with broad medical applications ranging from characterization of tumors and brain damage to potential prediction of stroke. Gradient coil and signal-to- noise ratio (SNR) constraints limit spatial …
-
Magnetic Resonance Mapping of Cerebrovascular Reserve: Steal Phenomena in Normal and Abnormal Brain
… level-dependent (BOLD) magnetic resonance (MR) imaging enables non-invasive spatial mapping of changes in cerebral blood flow (CBF). By applying a vasodilatory stimulus (such as inhaled CO2) during BOLD MR imaging, one can measure cerebral vasodilatory capacity. "Cerebrovascular reactivity" …
-
Mesoscopic structure through the prism of transverse relaxation
In standard MR images the contrast between different tissues is primarily determined via their distinctive relaxation rates resulting from differences in the molecular dipole-dipole interactions. In addition, the transverse relaxation in biological tissue is influenced by the heterogeneous magnetic …
-
Teigiamo ir neigiamo kontrasto nanodarinių taikymo magnetinio rezonanso vaizdinimui tyrimai in vivo /
Magnetic resonance imaging (MRI) is a widely used method for clinical diagnosis. To improve the diagnostic value of MR images, MRI contrast agents are often required. The most commonly used contrast agents are gadolinium-based compounds. Unfortunately, these contrast agents have several …
-
THREE INITIATIVES ADDRESSING MRI PROBLEMS
MRI is one of the most commonly used medical imaging techniques and the quest for higher image quality and reduced scan time has been driving various developments in this modality. In the thesis, three advances in MRI hardware and software are presented.Magnetic resonance fingerprinting (MRF) is a …
-
Design and Implementation of Calculated Readout by Spectral Parallelism (CRISP) in Magnetic Resonance Imaging (MRI)
… technique that offers theoretical increases in signal-to-noise ratio (SNR) and dynamic range over traditional methods in magnetic resonance imaging (MRI). The incoming broadband MRI signal is de-multiplexed into multiple narrow frequency bands using analog filters. Signal from each narrowband …
-
On Simulations of Spin Interactions Applied for the Volumetric T1 Quantification by in vivo Magnetic Resonance Imaging at Ultra High Field
… high field (UHF) magnetic resonance imaging (MRI) is introduced. It is based upon the prediction of the MR signal disturbances, due to static magnetic and RF field inhomogeneities as well as readout effects by the imaging process itself, and the corrections resulting hereof. For this reason, …
-
Permanent magnet based magnetic resonance sensors
… EP2069769A2 described using magnetic resonance (MR), instead of fluorescence, as the detection method for microarrays. This covered the concept of binding magnetic particles, such as Superparamagnetic Iron Oxide (SPIO), to a surface in order to change the MR signal that would normally be expected …
-
Diffusion MRI for Well-posed and Optimal White Matter Microstructure Characterisation: Beyond Single Diffusion Encoding
… brain tissue walls. Magnetic Resonance Imaging (MRI) provides macroscopic measurements of the diffusion process in a non-invasive manner, i.e. diffusion MRI. Hidden in these measurements lies information about the underlying architecture. The ability to unravel tissue microstructure from the …
-
Exploring myelin water imaging : from application to atlases to algorithms
… (MWI) is a quantitative magnetic resonance (MR) method that specifically measures the myelin content in the central nervous system. MWI operates on the principle that the MR signal of water trapped between myelin bilayers can be extracted from the total MR signal based on a characteristic …
-
Responsive dual nanoparticle ¹⁹F magnetic resonance molecular imaging probes
… of disease. Magnetic resonance imaging (MRI) is an excellent candidate for molecular imaging due to a lack of ionizing radiation, high spatial resolution and unlimited penetration depth. ¹⁹F MRI benefits from a very low biological background signal and can provide complementary …
-
Rapid Magnetic Resonance Imaging of Tissue Motion with Adaptive Velocity Sensitivity for Evaluating Cardiovascular Function
… in the phase of a magnetic resonance imaging (MRI) signal led to the development of the so-called phase contrast MRI (PC-MRI) method. Despite the well-recognized benefits of PC-MRI, clinical adoption has lagged because these techniques suffer from velocity-to-noise ratio (VNR)/aliasing …
-
RAPID, HIGH-RESOLUTION, AND SIGNAL-EFFICIENT METHODS FOR THE CLINICAL TRANSLATION OF BONE MAGNETIC RESONANCE IMAGING
Conventional magnetic resonance imaging (MRI) techniques emphasize the assessment of anatomical soft tissues. However, MR imaging of solid structures, like bone, may offer clinical utility. Unlike computed tomography (CT), MRI obviates the use of ionizing radiation and may perform spatial encoding …
-
Improved Arterial Input Function For Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Phase and T1 Measurements
… by performing Dynamic Contrast-Enhanced (DCE)-MRI. Using DCE-MRI, blood flow into a tumour from a nearby artery can be computed by measuring the concentration of an injected contrast agent as a function of time. This measurement, known as the arterial input function (AIF), can be computed based …
-
Highly Accelerated MRI: Prior Data Assisted Compressed Sensing for Lung Tumour Tracking
Hybrid magnetic resonance imaging (MRI) and radiation therapy devices are capable of imaging in real-time to track intrafractional lung tumour motion during radiotherapy. In the real time tumour tracking treatment scheme, MR images are acquired in real time, then the tumour target is localized …
-
Analysis of magnetic resonance imaging in inhomogenous main magnetic field
… study, analysis of Magnetic Resonance Imaging (MRI) in inhomogeneous main magnetic field is conducted. A numerical model based on Bloch equation is implemented for MRI, to understand effect of inhomogeneous magnetic field to Magnetic Resonance (MR) signal. Using the model, relations between …
Page 1 of 7