Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"MRI Compatibility"”

  1. MRI-compatibility enhancements to USM performance for interventional devices in MR environments

    … safe performance of magnetic resonance imaging (MRI)-guided robot-assisted interventions requires full control and high precision of assistive devices and tools. Because many currently available tools are not MRI-compatible, the characterization of existing tools and development of new ones are …

    toronto-retro Repository record for MRI-compatibility enhancements to USM performance for interventional devices in MR environments (opens in a new tab)

  2. Development of a Monolithic Implantable Neural Interface from Cubic Silicon Carbide and Evaluation of Its MRI Compatibility

    … inertness. It has the benefit of demonstrated biocompatibility, which makes it a promising candidate for chronically-stable, implantable INIs. In the first section of this dissertation, the fabrication and initial electrochemical characterization of a monolithic, Michigan-style 3C-SiC …

    usf Repository record for Development of a Monolithic Implantable Neural Interface from Cubic Silicon Carbide and Evaluation of Its MRI Compatibility (opens in a new tab)

  3. Design and control of a pneumatically driven MRI-compatible tele-operated haptic interface

    … rehabilitation in Magnetic Resonance Imaging (MRI). Pneumatic actuators have excellent MRI-compatibility as opposed to conventional electro-mechanical systems; however, the actuator and the system drivers cannot be co-located due to the MRI-compatibility requirements. The actuators are driven …

    gatech Repository record for Design and control of a pneumatically driven MRI-compatible tele-operated haptic interface (opens in a new tab)

  4. Design of a 2D MRI compatible robot for performing prostate cancer treatment using therapeutic ultrasound

    … prostate cancer. Magnetic resonance image (MRI) guidance of therapeutic ultrasound permits targeting and monitoring of therapy. In this thesis a prototype MRI compatible positioning device for the treatment of prostate cancer using therapeutic ultrasound is presented. The accuracy, MRI …

    city-london Repository record for Design of a 2D MRI compatible robot for performing prostate cancer treatment using therapeutic ultrasound (opens in a new tab)

  5. MRI Compatible Retention System for a Bone Conduction Device: An evaluation of required design changes to Sentio Ti™ Implant for compliance with 3 T MRI scans

    Magnetic resonance imaging (MRI) compatibility is an important requirement for implantable hearing devices, as increasing numbers of patients are expected to undergo MRI examinations during their lifetime. This study evaluates the mechanical response of the Sentio Ti™ transcutaneous bone conduction …

    chalmers Repository record for MRI Compatible Retention System for a Bone Conduction Device: An evaluation of required design changes to Sentio Ti™ Implant for compliance with 3 T MRI scans (opens in a new tab)

  6. DESIGN, DEVELOPMENT, AND EVALUATION OF A MRI-GUIDED NEUROSURGICAL INTRACRANIAL ROBOT

    … propose to develop a Magnetic Resonance Imaging (MRI)-compatible neurosurgical robot. The robot can be operated under continuous MRI, and the Magnetic Resonance (MR) images can be used to supplement physicians' visual capabilities, resulting in precise tumor removal. We have developed two …

    maryland Repository record for DESIGN, DEVELOPMENT, AND EVALUATION OF A MRI-GUIDED NEUROSURGICAL INTRACRANIAL ROBOT (opens in a new tab)

  7. Soft carbon nanotube fiber electrodes for multimodal neural interfacing

    … electrodes during magnetic resonance imaging (MRI), while MRI allows global brain activity detection and serves as an important and commonly used tool in neuroscience researches and clinical applications. Therefore, a neural electrode that integrates MRI compatibility and forms stable chronic …

    gatech Repository record for Soft carbon nanotube fiber electrodes for multimodal neural interfacing (opens in a new tab)

  8. Development of endovascular stent-grafts based on a nanocomposite polymer

    … on ePTFE (expanded polytetrafluoroethylene). MRI compatibility of the thoracic stent-graft was assessed by analysing signal attenuation and velocity measurements (flux) and compared to FDA-approved Medtronic ValiantTM. Results: The stent-graft had expanded diameter of 31.1 mm and was …

    ucl Repository record for Development of endovascular stent-grafts based on a nanocomposite polymer (opens in a new tab)

  9. Design and Testing of a Switch Mode, Precisely Adjustable Current Driver For Use in an MRI-Compatible Robotic Catheter System

    … thesis presents the design, implementation, and MRI performance evaluation of a novel, precisely adjustable current driver for an MRI guided robotic catheter system intended for cardiac ablation and similar procedures requiring a directed catheter in an MRI. The proposed system uses a modular, …

    ohiolink Repository record for Design and Testing of a Switch Mode, Precisely Adjustable Current Driver For Use in an MRI-Compatible Robotic Catheter System (opens in a new tab)

  10. fMRI-compatible robotic wrist rehabilitation manipulandum: design, prototyping, and implementation

    … of this thesis lie in developing an MRI-compatible three-degree-of-freedom (3-DOF) robotic manipulandum, designed for enhancing neurological rehabilitation exercises that focus on the wrist and forearm. Seamlessly integrated with an existing rehabilitation interactive computer game, …

    manitoba Repository record for fMRI-compatible robotic wrist rehabilitation manipulandum: design, prototyping, and implementation (opens in a new tab)

  11. Development of Wireless Implantable Micro Flow Sensor for Conditional Monitoring of VP Shunts

    … report suggesting a lifespan of 15 to 55 years. MRI compatibility analysis showed a sensitivity reduction of 64% in the device. Several in vivo recalibration methods were introduced to eliminate the calibration error. A protein deposition study showed stable sensor performance under 1.5 mg/ml …

    arizona-thes Repository record for Development of Wireless Implantable Micro Flow Sensor for Conditional Monitoring of VP Shunts (opens in a new tab)

  12. New Technology and Techniques for Needle-Based Magnetic Resonance Image-Guided Prostate Focal Therapy

    … is not yet certain. Magnetic resonance image (MRI)-guided focal laser ablation (FLA) therapy is a promising potential treatment option for select men with localized prostate cancer, and may result in fewer side effects than whole-gland therapies, while still achieving oncologic control. The …

    uwo Repository record for New Technology and Techniques for Needle-Based Magnetic Resonance Image-Guided Prostate Focal Therapy (opens in a new tab)

  13. Self-Adjustable Valve for Glaucoma Treatment: From Concept to First-in-Human Validation

    … graft-free implantation, and (iv) maintain MRI compatibility without introducing additional design constraints. This thesis addresses these limitations through the development and validation of a passive, self-adjustable glaucoma valve designed to maintain IOP within the physiological range …

    epfl Repository record for Self-Adjustable Valve for Glaucoma Treatment: From Concept to First-in-Human Validation (opens in a new tab)

  14. Image Guided Robots for Urology

    … developed for percutaneous access of the kidney. MRI-guided robots were developed for transrectal and transperineal prostate biopsy. Extensive in-vitro tests were performed to ensure MRI compatibility and image-guided accuracy of the robots. The transrectal robot was evaluated in an animal study …

    jhu Repository record for Image Guided Robots for Urology (opens in a new tab)

  15. Application of Smart Materials in Energy Harvesting and Wave Propagation

    … not limited to satisfying the size limitations, MRI compatibility, sufficient power output, reliability, and robustness. The proposed devices are designed and optimized to convert the heartbeat vibrations to the electricity needed for conventional and modern leadless pacemakers. The energy …

    buffalo Repository record for Application of Smart Materials in Energy Harvesting and Wave Propagation (opens in a new tab)

  16. Electrochemical corrosion evaluation of niobium and its alloys as metallic bio-implants

    Biocompatibility is the primary difference distinguishing biomaterials from other engineering materials. Corrosion resistance becomes important since the corrosion rate is strictly related to the ion release of biomaterials. Niobium (Nb) could be one of the potential materials to be used as …

    ubc Repository record for Electrochemical corrosion evaluation of niobium and its alloys as metallic bio-implants (opens in a new tab)

  17. Development of Carbon and Silicon Carbide Based Microelectrode Implantable Neural Interfaces

    … model is suggested along with investigating the MRI compatibility of the carbon electrodes which, along with the proven MRI compatibility of the Gen 1 all-SiC devices at 7 Tesla, would further motivate investment into the development of both of these highly promising mINI concept.

    usf Repository record for Development of Carbon and Silicon Carbide Based Microelectrode Implantable Neural Interfaces (opens in a new tab)

  18. ELECTROCHEMICAL PROPERTIES OF SiC-C MICROELECTRODE SYSTEM FOR NEURONAL AND BIOCHEMICAL SENSING

    … limitations related to performance degradation, MRI compatibility and tip placement, attributed to their metallic nature. The prototype new electrode system incorporates features including high electrochemical and mechanical stability, enhanced biochemical sensing, non-metallic electrode and …

    ohiolink Repository record for ELECTROCHEMICAL PROPERTIES OF SiC-C MICROELECTRODE SYSTEM FOR NEURONAL AND BIOCHEMICAL SENSING (opens in a new tab)

  19. Supervised Deep Learning with Finite Element Synthetic Data for Force Estimation in Robotic-assisted Surgery

    … surgical site, which brings sterilization, biocompatibility, and MRI compatibility concerns. On the other hand, Dynamic robot modeling may be precise in a specific setting, but it suffers from the lack of generalization encountering unseen settings. Considering the drawbacks and deficits of …

    concordia

Page 1 of 2