Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 38 for “"MRI Environment"”
-
Design of a neurosurgical manipulator for applications in MRI environment
… allowed placement of actuators outside the MRI bore. The robot is modeled using Denavit-Hartenberg transformations. Custom developed software control is developed to test the functional aspects of the robot. The robot performs to the tolerance required for the stated clinical application. …
-
Static Magnetic Field Interactions of Medical Devices in The MRI Environment
… force, experienced by any medical device in any MRI-relevant environment is developed. This computational model is validated through comparison to derived analytic solutions and experimental testing performed in accordance to ASTM F2052-15. Results: Through analytic validation, it is found that …
-
Development of a high-resolution, MRI-compatible PET detector using digital silicon photomultipliers
… tomography (PET) and magnetic resonance imaging (MRI) promises to combine superior functional and anatomical information into a single examination, but poses a number of engineering challenges. In particular, the development of MRI-compatible photodetectors is a key issue to realize PET/MRI at its …
-
Design And Fabrication of MR-Safe Core Needle Breast Biopsy Robot
… women worldwide. Excisional biopsy, especially MRI-guided percutaneous core-needle biopsy, remains a crucial diagnostic tool for breast cancer. However, MRI-guided biopsies present significant challenges, including the restricted space within the scanner bore and the necessity for multiple …
-
Design and Testing of a Switch Mode, Precisely Adjustable Current Driver For Use in an MRI-Compatible Robotic Catheter System
… thesis presents the design, implementation, and MRI performance evaluation of a novel, precisely adjustable current driver for an MRI guided robotic catheter system intended for cardiac ablation and similar procedures requiring a directed catheter in an MRI. The proposed system uses a modular, …
-
Design and Prototyping of a Coil-Driven Actuated Catheter for Use in an MRI-Guided Robotic Catheter System
… radiation. Utilizing magnetic resonance imaging (MRI) in these procedures offers three-dimensional catheter visualization and eliminates radiation exposure. The MRI’s magnetic field can be leveraged in order to control a robotic ablation catheter with small electromagnetic coils in the catheter …
-
Sweet Dreams Are Made of These: Investigating the Neural Mechanisms of Dream Traits and States
… including structural and functional MRI, diffusion imaging, and simultaneous EEG/fMRI. By addressing methodological challenges and leveraging large-scale datasets, the studies provide novel insights into the neural correlates of dream recall and dreaming during sleep. A systematic …
-
Object detection learning : effects of transcranial direct current stimulation, magnetic resonance imaging, and image novelty
… one hour to detect objects hidden in a virtual environment. Anodal tDCS was applied over the right inferior frontal cortex at 0.1 mA or 2.0 mA for 30 minutes during training. Participants were tested immediately before and after training and again one hour later. Some test stimuli were repeated …
-
Training and transfer of training in rapid visual search under high target-background similarity
… in attentional networks with training in an MRI environment in the future, a paradigm suitable for an fMRI study was tested to determine if the training and transfer benefits remained when using a rapid presentation search paradigm that relies on covert attention. Two groups of participants …
-
Systemic and cerebral hemodynamics in response to cardiovascular challenges : the heart-brain connection
… integration of physiological concepts into the MRI-environment and by monitoring brain perfusion at both the macrovascular level (using transcranial Doppler; TCD) and the tissue level (using arterial spin labeling MRI; ASL). This thesis focused on the comparison and validation of these two …
-
System For Exercise Stress Cardiac Magnetic Resonance Imaging
… of a radioisotope. Magnetic resonance imaging (MRI) can provide a comprehensive cardiac examination (function and perfusion) with higher quality images without the use of radiation.</p><p>The challenges of the MRI environment have prevented the successful combination of treadmill exercise stress …
-
Radio-Frequency Response Characterization and Design of Actuation Coils for a Novel MRI Guided Robotic Catheter System
… mitigated by using Magnetic Resonance Imaging (MRI) for this procedure. The magnetic field of the MRI machine can be strategically leveraged to steer and actuate a robotic ablation catheter, by energizing small embedded electromagnetic coils within the catheter tip. These coils however, may …
-
Catheter Insertion Mechanism for Real-Time MRI-Guided Robotic Assisted Cardiac Ablation
… image quality. The implementation of a real-time MRI-guided robotic-assisted catheter ablation system can eliminate radiation exposure, provide superior guidance, reduce inter-operator variability, and could result in increased success rates in the treatment of Afib. Such a system is being …
-
Reducing the Effects of MRI Acoustic Noise Using Micro-Perforated Panels
Magnetic resonance imaging (MRI) has revolutionized the field of cognitive neuroscience as it allows researchers to noninvasively map brain function in response to stimulus or task demands. However, the acquisition of MR images generates substantial acoustic noise, so that imaging studies of …
-
Optimizing MRI Experience for Children Living with Autism Spectrum Disorder
Magnetic Resonance Imaging (MRI) in pediatric patients living with Autism Spectrum Disorder (ASD) is often complicated by challenges. The child perceives the MRI environment as abnormal and uncertain of the implications of the procedure. The child may exhibit distress becoming anxious and …
-
Development of a Compact Piezoworm Actuator For Mr Guided Medical Procedures
… safely inside the magnetic resonance imaging (MRI) machine. The actuator based on novel design that generates linear and rotary motion simultaneously for higher needle insertion accuracy. One of the research main objectives is to aid in the selection of suitable materials for actuators used in …
-
Development and applications of a highly flexible nonlinear spatial encoding system for magnetic resonance imaging
… gradient coil for magnetic resonance imaging (MRI).<br><br>The design process addressed gradient strength, flexibility, magnetic shielding, cooling, electrical decoupling, balance of force and torque and patient safety. These demands were fulfilled by designing two different coil element types …
-
Advanced methods for enhanced sensing in biomedical Raman spectroscopy
… Raman probe that is compatible with surgical environments. This probe was originally developed to be compatible with Magnetic Resonance Imaging (MRI) environment. It has the potential to be used for performing minimally invasive optical biopsy during interventional MRI procedures.
-
A Novel Transmission Mechanism for MRI-Compatible Surgery Robot
… the open approach. Magnetic Resonance Imaging (MRI) is an intrinsically three-dimensional (3D) modality which offers high contrast and spatial resolution and a plethora of soft-tissue contrast mechanisms for assessment of anatomical morphology and function. These benefit , in addition to the …
-
Magnetic Resonance Imaging Assessment of Cardiovascular Function during Exercise A Clinical Study Investigating Treatment Effects in Aortic Disease
… can be evaluated by Magnetic Resonance Imaging (MRI) which provides detailed anatomical and functional information. Exercise stress testing is also an essential clinical tool to evaluate cardiovascular function. Cardiovascular changes induced by the additional metabolic demand under exercise, …
Page 1 of 2