MRI-compatibility enhancements to USM performance for interventional devices in MR environments
… safe performance of magnetic resonance imaging (MRI)-guided robot-assisted interventions requires full control and high precision of assistive devices and tools. Because many currently available tools are not MRI-compatible, the characterization of existing tools and development of new ones are …
-
Development of a Monolithic Implantable Neural Interface from Cubic Silicon Carbide and Evaluation of Its MRI Compatibility
… inertness. It has the benefit of demonstrated biocompatibility, which makes it a promising candidate for chronically-stable, implantable INIs. In the first section of this dissertation, the fabrication and initial electrochemical characterization of a monolithic, Michigan-style 3C-SiC …
-
Design and control of a pneumatically driven MRI-compatible tele-operated haptic interface
… rehabilitation in Magnetic Resonance Imaging (MRI). Pneumatic actuators have excellent MRI-compatibility as opposed to conventional electro-mechanical systems; however, the actuator and the system drivers cannot be co-located due to the MRI-compatibility requirements. The actuators are driven …
-
Design of a 2D MRI compatible robot for performing prostate cancer treatment using therapeutic ultrasound
… prostate cancer. Magnetic resonance image (MRI) guidance of therapeutic ultrasound permits targeting and monitoring of therapy. In this thesis a prototype MRI compatible positioning device for the treatment of prostate cancer using therapeutic ultrasound is presented. The accuracy, MRI …
-
MRI Compatible Retention System for a Bone Conduction Device: An evaluation of required design changes to Sentio Ti™ Implant for compliance with 3 T MRI scans
Magnetic resonance imaging (MRI) compatibility is an important requirement for implantable hearing devices, as increasing numbers of patients are expected to undergo MRI examinations during their lifetime. This study evaluates the mechanical response of the Sentio Ti™ transcutaneous bone conduction …
-
DESIGN, DEVELOPMENT, AND EVALUATION OF A MRI-GUIDED NEUROSURGICAL INTRACRANIAL ROBOT
… propose to develop a Magnetic Resonance Imaging (MRI)-compatible neurosurgical robot. The robot can be operated under continuous MRI, and the Magnetic Resonance (MR) images can be used to supplement physicians' visual capabilities, resulting in precise tumor removal. We have developed two …
-
Soft carbon nanotube fiber electrodes for multimodal neural interfacing
… electrodes during magnetic resonance imaging (MRI), while MRI allows global brain activity detection and serves as an important and commonly used tool in neuroscience researches and clinical applications. Therefore, a neural electrode that integrates MRI compatibility and forms stable chronic …
-
fMRI-compatible robotic wrist rehabilitation manipulandum: design, prototyping, and implementation
… of this thesis lie in developing an MRI-compatible three-degree-of-freedom (3-DOF) robotic manipulandum, designed for enhancing neurological rehabilitation exercises that focus on the wrist and forearm. Seamlessly integrated with an existing rehabilitation interactive computer game, …
-
Development of Wireless Implantable Micro Flow Sensor for Conditional Monitoring of VP Shunts
… report suggesting a lifespan of 15 to 55 years. MRI compatibility analysis showed a sensitivity reduction of 64% in the device. Several in vivo recalibration methods were introduced to eliminate the calibration error. A protein deposition study showed stable sensor performance under 1.5 mg/ml …
-
Image Guided Robots for Urology
… developed for percutaneous access of the kidney. MRI-guided robots were developed for transrectal and transperineal prostate biopsy. Extensive in-vitro tests were performed to ensure MRI compatibility and image-guided accuracy of the robots. The transrectal robot was evaluated in an animal study …
-
Application of Smart Materials in Energy Harvesting and Wave Propagation
… not limited to satisfying the size limitations, MRI compatibility, sufficient power output, reliability, and robustness. The proposed devices are designed and optimized to convert the heartbeat vibrations to the electricity needed for conventional and modern leadless pacemakers. The energy …
-
Electrochemical corrosion evaluation of niobium and its alloys as metallic bio-implants
Biocompatibility is the primary difference distinguishing biomaterials from other engineering materials. Corrosion resistance becomes important since the corrosion rate is strictly related to the ion release of biomaterials. Niobium (Nb) could be one of the potential materials to be used as …
-
Development of Carbon and Silicon Carbide Based Microelectrode Implantable Neural Interfaces
… model is suggested along with investigating the MRI compatibility of the carbon electrodes which, along with the proven MRI compatibility of the Gen 1 all-SiC devices at 7 Tesla, would further motivate investment into the development of both of these highly promising mINI concept.
-
Supervised Deep Learning with Finite Element Synthetic Data for Force Estimation in Robotic-assisted Surgery
… surgical site, which brings sterilization, biocompatibility, and MRI compatibility concerns. On the other hand, Dynamic robot modeling may be precise in a specific setting, but it suffers from the lack of generalization encountering unseen settings. Considering the drawbacks and deficits of …
-
Clinical Compatibility of an Implantable Pressure Sensing Device With Consideration of the Intracranial Pressure Application
… reader wand. This thesis reports on the clinical compatibility of a pressure monitoring system. Pressure measurement stability over time has been a major cause of failure for previous attempts at a long term ICP device, and this research has shown some (but not all) pressure sensors do have …
-
Design, development, and evaluation of meso-scale robotic system for deep intracranial tumor removal
… approach, and magnetic resonance imaging (MRI) to achieve more precise and complete removal of brain tumor. MINIR-II is a spring-based 3-D printed flexible robot that is tendon-driven and equipped with electrocautery, suction and irrigation capabilities. A novel central tendon routing …
-
Tissue Stabilization in MRI-Guided Breast Biopsy
… Contrast-enhanced Magnetic Resonance Imaging (MRI) is often used for guiding the biopsy in those cases in which the tumor may not be detectable under Ultrasound or X-ray mammography. Stabilization of the breast tissue during the biopsy is critical for its success to ensure that the target would …
-
Phonon Modulation By Polarized Lasers For Material Modification
Magnetic resonance imaging (MRI) has become one of the premier non-invasive diagnostic tools, with around 60 million MRI scans applied each year. However, there is a risk of thermal injury due to radiofrequency (RF) induction heating of the tissue and implanted metallic device for the patients with …
-
Sensors and System Integration for Magnetic Resonance Image (MRI)-Guided and Robot-Assisted Interventions
Demand for magnetic resonance image (MRI)-guided interventions and robot-assisted surgeries continues to increase in the field of medical robotics. MRI-guided interventions provide pre-/intra-operative MR images and intraoperative manipulations. Robot-assisted surgeries guarantee higher safety and …