  1. Reducing Acoustic Noise in MRI Scanners

    … acoustic noise in magnetic resonance imaging (MRI) scanners is presented in this thesis. The structural-acoustic coupling mechanism of MRI scanners was investigated using a method of structural-acoustic modal analysis. Mathematical expressions of generalized radiation impedances of gradient …

    queens Repository record for Reducing Acoustic Noise in MRI Scanners (opens in a new tab)

  2. Registration of Total Hip Replacement Implants from Subjects Imaged with 1.5 and 3 Tesla MRI Scanners Using Mavric

    … to the presence and wear of the implant. MRI is an imaging modality that can assess and diagnosis the diseases ailing the periprosthetic tissues, however images of a metal implants are susceptible to artifacts. Aim 1 of this study was to register the THAs imaged at 3T to 1.5T images; Aim 2 …

    marquette Repository record for Registration of Total Hip Replacement Implants from Subjects Imaged with 1.5 and 3 Tesla MRI Scanners Using Mavric (opens in a new tab)

  3. Radio Frequency Power Amplifiers Adapted For Low Field Magnetic Resonance Imaging

    Magnetic Resonance Imaging (MRI) is a reliable and established minimally invasive imaging technique that can provide diagnostically relevant information about the internal structures of the human body. While the basic design of the new MRI scanners is not much different from when they were first …

    sask Repository record for Radio Frequency Power Amplifiers Adapted For Low Field Magnetic Resonance Imaging (opens in a new tab)

  4. Quantitative MRI quality control using the ACR phantom

    … many studies have used T1 and T2 quantitative MRI in examining the brain and other body structures, to evaluate and follow up diseases, or simply for better understanding of the human body. Quality control on MRI scanners has been performed since the early eighties and nowadays the ACR MRI …

    bu Repository record for Quantitative MRI quality control using the ACR phantom (opens in a new tab) Embargoed until 2999-01-01

  5. Effects of acute and chronic noise exposure on cochlear function and hearing in dogs

    … hospitals, Magnetic Resonance Imaging (MRI) scanners are used daily in diagnostics of dogs. MRI scanners omit high levels of acoustic noise, which is known to be damaging to the hearing of human patients without effective ear protection. However, the effects of the MRI noise levels on …

    glasgow Download PDF for Effects of acute and chronic noise exposure on cochlear function and hearing in dogs (opens in a new tab)

  6. Two-dimensional spectroscopy of γ-aminobutyric acid on a clinical MRI scanner

    … acid (GABA) has been performed on clinical MRI scanners using a variety of magnetic resonance spectroscopy (MRS) techniques. MRS studies of GABA are difficult, especially at 1.5T due to low in-vivo concentrations and overlapping of higher concentration metabolites. Unlike spectral editing …

    edinburgh Repository record for Two-dimensional spectroscopy of γ-aminobutyric acid on a clinical MRI scanner (opens in a new tab)

  7. Gadoxetsäure-verstärkte Magnetresonanztomographie als bildgestützter Leberfunktionstest

    … acid-enhanced magnetic resonance imaging (MRI) as an imaging-based liver function test. In this context, we compared gadoxetic acid-enhanced MRI T1 relaxometry-derived indices with the 13C-methacetin breath test (LiMAx test) in 53 patients who underwent MRI examinations less than 30 days …

    fu-berlin Repository record for Gadoxetsäure-verstärkte Magnetresonanztomographie als bildgestützter Leberfunktionstest (opens in a new tab)

  8. Nachweis Kontrastmittel-markierter humaner hämatopoetischer Vorläuferzellen im Mausmodell mit der Magnetresonanztomographie

    … hematopoetic progenitor cells in nude mice using MRI and optical imaging. Techniques for cell-labelling with MR contrast agents and subsequent in vivo depiction by imaging modalities were developed and optimized. Conclusion: The biodistribution of iron oxide as well as gadophrin labeled progenitor …

    lmu-germany Repository record for Nachweis Kontrastmittel-markierter humaner hämatopoetischer Vorläuferzellen im Mausmodell mit der Magnetresonanztomographie (opens in a new tab)

  9. Assessment of knee cartilage mechanics using the magnetization transfer ratio

    … that lead to OA. Magnetic resonance imaging (MRI) techniques such as T2 and T1ρ have shown sensitivity to mechanical changes in cartilage. However, the response is depth-dependent, and clinical MRI scanners with lower image resolutions cannot detect such specific changes. The magnetization …

    ubc Repository record for Assessment of knee cartilage mechanics using the magnetization transfer ratio (opens in a new tab) Download PDF for Assessment of knee cartilage mechanics using the magnetization transfer ratio (opens in a new tab)

  10. Design and Control of a Magnetic Hammer Millirobot for Tissue Penetration

    … for minimally invasive surgery or drug delivery. MRI scanners can generate magnetic gradients to apply propulsive forces on ferromagnetic objects. However, MRI gradient forces are insufficient for tissue penetration. This project presents a millirobot design and control methods to produce pulsed …

    houston Repository record for Design and Control of a Magnetic Hammer Millirobot for Tissue Penetration (opens in a new tab)

  11. Development and validation of non-contrast MRI techniques for the measurement of cerebral blood volume

    The inflow-based vascular space occupancy (iVASO) MRI technique was developed to measure arterial cerebral blood volume (CBVa). The integration of vascular crushers within iVASO amplifies signal sensitivity, particularly targeting small pial arteries and arterioles. In this dissertation, we aim to …

    jhu Repository record for Development and validation of non-contrast MRI techniques for the measurement of cerebral blood volume (opens in a new tab)

  12. Multicentre evaluation of MRI variability in the quantification of infarct size in experimental focal cerebral ischaemia

    … research. Magnetic resonance imaging (MRI) could be pivotal in such studies due to its non-invasive nature and its high sensitivity to ischaemic lesions, but its accuracy and concordance across centres has not yet been evaluated. This thesis focussed on the use of MRI for the assessment …

    edinburgh Repository record for Multicentre evaluation of MRI variability in the quantification of infarct size in experimental focal cerebral ischaemia (opens in a new tab)

  13. 1H and 31P MR Spectroscopic Imaging of the prostate at 7 Tesla

    … very important to assess this very accurately. MRI scans can be used for this purpose. The location and size of prostate cancer can be recognized on an MR image of the prostate. It is also possible to estimate the aggressiveness of the cancer using MRI. During this PhD research, new techniques …

    radboud Repository record for 1H and 31P MR Spectroscopic Imaging of the prostate at 7 Tesla (opens in a new tab) Download PDF for 1H and 31P MR Spectroscopic Imaging of the prostate at 7 Tesla (opens in a new tab)

  14. Numerical and Experimental Study of Pacemaker Safety under MRI

    Pacemaker safety issues with MRI (Magnetic Resonance Imaging) are discussed in this thesis. In order to analyze the electromagnetic compatibility issue of pacemaker/defibrillator with MRI RF (radio frequency) coil and human body model, novel techniques for the evaluation of MRI-induced heating or …

    houston Repository record for Numerical and Experimental Study of Pacemaker Safety under MRI (opens in a new tab)

  15. Assessment of MRI scanner performance for preclinical functional studies

    Functional Magnetic Resonance Imaging (fMRI) based studies are rapidly expanding in the field of preclinical research. The majority of these studies use Echo Planar Imaging (EPI) to measure Blood Oxygenation Level Dependent (BOLD) signal contrasts in the brain. In such studies the magnitude and …

    edinburgh Repository record for Assessment of MRI scanner performance for preclinical functional studies (opens in a new tab)