Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 89 for “"MRI system"”

  1. An investigation into a flux-pumped high-temperature superconducting MRI system

    … high-field magnets, Magnetic Resonance Imaging (MRI) magnets, fusion magnets, superconducting fault current limiters, energy storage devices, and many others. Among all of the applications, MRI magnets make up the major part of the commercial application of superconductors. More than 80 % of MRI …

    cambridge Repository record for An investigation into a flux-pumped high-temperature superconducting MRI system (opens in a new tab)

  2. MICROFABRICATION OF MAGNETIC MICRO-GRIPPERS AND THEIR NAVIGATION USING MRI SYSTEM

    … the recent decades, magnetic resonance imaging (MRI) has become one of the most important technologies in medical science that can provide a safe, convenient and high-quality imaging of the human body. By exploiting the imaging and magnetic navigation features of the MRI system, researchers have …

    jhu Repository record for MICROFABRICATION OF MAGNETIC MICRO-GRIPPERS AND THEIR NAVIGATION USING MRI SYSTEM (opens in a new tab)

  3. Development of a Novel MRI system for Preclinical Small Animal Radiation Experiments

    … interferences between the scanner and the x-ray system. This thesis work proposes a novel low-field single-sided MR system that can potentially enable preclinical MR-guided radiation studies. We utilized an inhomogeneous single-sided ultra-low-field MR design to achieve geometric and magnetic …

    utswmed Repository record for Development of a Novel MRI system for Preclinical Small Animal Radiation Experiments (opens in a new tab)

  4. Adaptation of advanced MRI and NMR technique for low magnetic field MRI system.

    … techniques, including nuclear magnetic imaging (MRI) and nuclear magnetic resonance (NMR) relaxometry are increasingly gaining interest and acceptance by food scientists and engineers. These techniques are being used to study moisture and fat content, water mobility, and distribution of water, …

    umn Repository record for Adaptation of advanced MRI and NMR technique for low magnetic field MRI system. (opens in a new tab)

  5. Design and analysis of a compact high-torque permanent magnet vernier machine for a portable MRI system

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2025-10-20 without embargo terms

    uiuc Repository record for Design and analysis of a compact high-torque permanent magnet vernier machine for a portable MRI system (opens in a new tab)

  6. A 24-channel radio frequency receive array for magnetic resonance imaging of primates at 10.5 T

    Magnetic resonance imaging (MRI) is a unique modality which offers many advantages and challenges compared to other imaging technologies. The radio frequency (RF) coil is one of the key hardware sub-systems, which drives overall MRI system performance to enable higher resolution imaging and the …

    umn Repository record for A 24-channel radio frequency receive array for magnetic resonance imaging of primates at 10.5 T (opens in a new tab)

  7. A 20-coil array system for high-throughput dynamic contrast-enhanced mouse MRI

    MRI is a versatile tool for systematically assessing anatomical and functional changes in small animal models of human disease. Its noninvasive nature makes MRI an ideal candidate for longitudinal evaluation of disease progression in mice; however achieving the desired level of statistical power …

    texas Repository record for A 20-coil array system for high-throughput dynamic contrast-enhanced mouse MRI (opens in a new tab)

  8. Magnetic resonance imaging of transmembrane water permeability for detection of cell death

    … were implemented on a preclinical and clinical MRI system. The AXR is shown as a contrast agent-free early cell death imaging biomarker in vitro and in vivo. A pilot study in patients demonstrates the translatability of AXR measurements to the clinic.

    greece Repository record for Magnetic resonance imaging of transmembrane water permeability for detection of cell death (opens in a new tab)

  9. Liquid-state nuclear hyperpolarization without a polarizer : synthesis amid the magnet bore allows a dramatically enhanced nuclear alignment

    … is lost during the transfer of the tracer to the MRI system. <br>In this thesis, parahydrogen (pH2) induced polarization (PHIP) of carbon-13 of P13C > 10 % was achieved for the first time inside a preclinical 7 Tesla MR imaging (MRI) system. In addition to the MRI system, only little extra …

    freiburg-diss Repository record for Liquid-state nuclear hyperpolarization without a polarizer : synthesis amid the magnet bore allows a dramatically enhanced nuclear alignment (opens in a new tab)

  10. Magnetic Resonance Imaging of Susceptibility Effects in Carotid Atherosclerosis

    … a group of patients who underwent USPIO enhanced MRI on a 1.5T MRI system. Images were acquired prior to infusion and 48 hours post infusion. SWI and gradient echo phase images were used to depict the field inhomogeneities generated by diamagnetic and paramagnetic materials within the plaques, …

    cambridge Repository record for Magnetic Resonance Imaging of Susceptibility Effects in Carotid Atherosclerosis (opens in a new tab)

  11. Σχεδίαση, ανάπτυξη και κλινική εφαρμογή πηνίων φασικής συνάφειας για απεικόνιση και φασματοσκοπία μαγνητικού συντονισμού

    … We simulated a 4-channel phased array system of orthogonal elements with reduced size compare to the conventional coils in order to improve the signal-to-noise ratio in prostate MR imaging. That system was then designed and developed using particular decoupling, tuning, matching and …

    greece Repository record for Σχεδίαση, ανάπτυξη και κλινική εφαρμογή πηνίων φασικής συνάφειας για απεικόνιση και φασματοσκοπία μαγνητικού συντονισμού (opens in a new tab)

  12. The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging

    … ratio (SNR) issue in magnetic resonance imaging (MRI). In the first part of the thesis (Chapter 2), an invasive microwave breast cancer therapy which uses the needle insertion to guide microwave power into the tumor region is investigated through the calculation of specific absorption rate (SAR) …

    nus Repository record for The Application of Electromagnetic Theory in Microwave Therapy and Magnetic Resonance Imaging (opens in a new tab)

  13. Magnetic Resonance Imaging Techniques for Rodent Pulmonary Imaging

    Magnetic Resonance Imaging (MRI) is a safe and widely used diagnostic imaging method that allows in vivo observation of anatomy and characterization of tissues. MRI provides a method to monitor patients without invasive measures, making it suitable for both diagnostics and longitudinal monitoring …

    arizona-thes Repository record for Magnetic Resonance Imaging Techniques for Rodent Pulmonary Imaging (opens in a new tab)

  14. A 200-MHz fully-differential CMOS front-end with an on-chip inductor for magnetic resonance imaging

    … front-end for a magnetic resonance imaging (MRI) system to perform microspectroscopy. The research has succeeded in producing good function- ality for a multiple-channel sensor. The sensor met expectations compared to similar one-channel systems through experiments in channel separation and …

    tamu Repository record for A 200-MHz fully-differential CMOS front-end with an on-chip inductor for magnetic resonance imaging (opens in a new tab)

  15. A Study of Sensitivity Mapping Techniques for Multi-Channel MR Coils

    … hand in hand with Magnetic Resonance Imaging (MRI) technology to complement one another to provide the highest level improvements to patient screening. The technical innovations for MRI machines are based on marketing requirements that are driven by the inputs provided by clinical radiologists. …

    ohiolink Repository record for A Study of Sensitivity Mapping Techniques for Multi-Channel MR Coils (opens in a new tab)

  16. A multi-echo spin echo wrist MRI dataset at 1 Tesla

    Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast but is slow and costly, motivating the development of accelerated and data-driven reconstruction methods. Recent advances in machine learning for MRI rely heavily on high-quality datasets; however, most existing datasets do …

    texas Repository record for A multi-echo spin echo wrist MRI dataset at 1 Tesla (opens in a new tab) Embargoed until 2028-05-01

  17. An 8 Channel Transmit-Receive RF Volume Coil for Magnetic Resonance Imaging

    … of the prototype was measured using the MRI system. Magnetic field simulations were compared to flip angle maps, comparing transmit fields, and receive sensitivities were compared to measured signal intensities. Full electronics characterization is described, and optimization was achieved …

    marquette Repository record for An 8 Channel Transmit-Receive RF Volume Coil for Magnetic Resonance Imaging (opens in a new tab)

Page 1 of 5