Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 87 for “"MRI-compatible"”.
-
The development of MRI-compatible SPECT system
In recent years, combined MRI and nuclear imaging techniques such as PET and SPECT have received great attentions. MRI provides high-resolution anatomical and functional information along with an exquisite soft tissue contrast. Nuclear techniques could provide an excellent sensitivity to …
-
A Novel Transmission Mechanism for MRI-Compatible Surgery Robot
… the open approach. Magnetic Resonance Imaging (MRI) is an intrinsically three-dimensional (3D) modality which offers high contrast and spatial resolution and a plethora of soft-tissue contrast mechanisms for assessment of anatomical morphology and function. These benefit , in addition to the …
-
MRI compatible robotic positioning system for an arborizing multiport catheter
… This thesis describes the development of an MRI-compatible system for remotely positioning the arborizing catheter, allowing for precision control of drug infusion points while the infusion is viewed in real time from an MRI control room. Actuation mechanisms, made using all MRI-compatible …
-
DESIGN AND IMPLEMENTATION OF AN MRI-COMPATIBLE MOTOR TEST STAND
… trend has emerged to expand the use of robots to MRI-guided surgeries. This is due to its safe working principle, its versatility and its superior image quality over X-ray and CT. However, the strong magnetic field created poses serious constraints on the electronics and materials used in these …
-
MAGNETIC RESONANCE IMAGING (MRI) COMPATIBLE ROBOT FOR LUMBAR PUNCTURE PROCEDURE
… particularly in obese patients with excess fat. MRI is known for its ability to detect soft tissues and accurately locate vertebrae and CSF. This research aims to develop an MRI image-guided robot that can perform the needle insertion steps in a lumbar puncture procedure. The robot's components, …
-
Development of a cost-effective detector for an MRI compatible brainPET
… the development of a Magnetic Resonance Imaging (MRI) compatible small animal Positron Emission Tomography (PET) insert, the University of Manitoba PET lab aims to develop an MRI compatible brainPET designed to retrofit into the Siemens Magnetom 7 T brain MRI. The purpose of this device is to …
-
Inverted compound eye camera for second generation MRI compatible SPECT system
… evaluate a novel design of the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept inspired by compound eyes often found in small invertebrates. The MRC-SPECT II system is constructed with a total of 24 ICE-camera panels that …
-
Development of a high-resolution, MRI-compatible PET detector using digital silicon photomultipliers
… tomography (PET) and magnetic resonance imaging (MRI) promises to combine superior functional and anatomical information into a single examination, but poses a number of engineering challenges. In particular, the development of MRI-compatible photodetectors is a key issue to realize PET/MRI at its …
-
Design and control of a pneumatically driven MRI-compatible tele-operated haptic interface
… rehabilitation in Magnetic Resonance Imaging (MRI). Pneumatic actuators have excellent MRI-compatibility as opposed to conventional electro-mechanical systems; however, the actuator and the system drivers cannot be co-located due to the MRI-compatibility requirements. The actuators are driven …
-
A force and displacement self-sensing method for a mri compatible tweezer end effector
… technique for a piezoelectrically driven MRI-compatible tweezer style end effector, suitable for robot assisted, MRI guided surgery. Nested strain amplification mechanisms are used to amplify the displacement of the piezo actuators to practical levels for robotics. By using a hysteretic …
-
Design of a 2D MRI compatible robot for performing prostate cancer treatment using therapeutic ultrasound
… prostate cancer. Magnetic resonance image (MRI) guidance of therapeutic ultrasound permits targeting and monitoring of therapy. In this thesis a prototype MRI compatible positioning device for the treatment of prostate cancer using therapeutic ultrasound is presented. The accuracy, MRI …
-
Development of MRI-compatible Transducer Array for Focused Ultrasound Surgery: : The Use of Relaxor-based Piezocrystals
… the development of ultrasound arrays for MRI guided FUS, from the point of view of the potential piezoelectric material of choice. Two materials are of particular interests in this work: Binary (x)Pb(Mg1/3Nb2/3) O3 - (1-x)PbTiO3 (PMN-PT) piezocrystal, and newly specialized FUS material, …
-
Design and development of magnetic resonance imaging (MRI) compatible tissue mimicking phantoms for evaluating focused ultrasound thermal protocols
… these phantoms are to be geometrically accurate, compatible with magnetic resonance imaging (MRI) and to be composed of materials that approximate the acoustic and thermal properties of the replicated tissues. Throughout the duration of the project three ultrasonic composite phantoms (head, femur …
-
DESIGN AND DEVELOPMENT OF AN MRI-COMPATIBLE ROBOT TO OPERATE A TENDON-DRIVEN ACTIVE NEEDLE FOR PERCUTANEOUS NEEDLE PLACEMENT
… imaging modalities such as ultrasound and CT. MRI provides excellent real-time imaging feedback for the operator to target lesions with greater confidence. Using a teleoperated robotic interface can further increase this targeting confidence when performing interventions guided by MRI, a method …
-
The design and implementation of a CT and MRI compatible multipurpose phantom: testing the effectiveness of multiple contrast material concentrations for CTA
The purpose of our study was to determine if it is possible to acquire CTA images of small vessels using lower concentrations of iodinated contrast material without substantially diminishing image quality. A custom designed multi-purpose phantom was used to test multiple concentrations of iodinated …
-
MRI Compatible Retention System for a Bone Conduction Device: An evaluation of required design changes to Sentio Ti™ Implant for compliance with 3 T MRI scans
Magnetic resonance imaging (MRI) compatibility is an important requirement for implantable hearing devices, as increasing numbers of patients are expected to undergo MRI examinations during their lifetime. This study evaluates the mechanical response of the Sentio Ti™ transcutaneous bone conduction …
Page 1 of 5