Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 36 for “"MRM mode"”
-
Qualitative and Quantitative analysis of glycans and glycopeptides released from model glycoproteins and biological samples using MRM mode and ESI LC-MS/MS
… as transitions in multiple reaction monitoring (MRM) mode. The invariable presence of oxonium ions as a result of fragmentation of glycopeptides makes them an excellent choice as transitions for MRM of the glycopeptides. MRM on a triple quadrupole mass spectrometer enables very high sensitivity …
-
Qualitative and quantitative analysis of glycans released from model glycoproteins and pooled human blood serum using MRM Mode and ESI LC-MS/MS
… of permethylated N-glycans derived from model glycoproteins, such as fetuin, a-1 acid glycoprotein and ribonuclease B, offered more sensitive and reproducible results than offline liquid–liquid and solid-phase extractions. The online solid-phase purification method described here …
-
Application of Atmospheric Pressure Chemical Ionization Gas Chromatography in Urine Organic Acid Analysis
… use. Furthermore, utilizing the machine’s MRM mode would increase sensitivities thus allowing for hopefully quantitative analysis. Chemical standards and patient urine samples were extracted via a liquid-liquid ether extraction and derivatized with BSTFA for proper GC elution. Results were …
-
Polyamine Profiling Analysis by Liquid Chromatography–Tandem Mass Spectrometry in Plasma and Lung Tissues of Mice with Asthma
… method and multiple reaction monitoring (MRM) mode for simultaneous measurement of four aliphatic and five acetylated PAs in plasma and lung tissue samples was developed by liquid chromatography–tandem mass spectrometry (LC−MS/MS). Characteristic ions in MRM mode with electrospray …
-
Metabolomic Study of Endogenous Steroid Hormones in Tissues of Ovarian Cancer Patients by Gas Chromatography−Tandem Mass Spectrometry
… spectrometry (GC−MS/MS). Characteristic ions in MRM mode with electron ionization (EI) permitted the accurate and selective analysis of endogenous steroid hormones. In optimal conditions, this method showed good linearity (r ≥ 0.9989) with limit of detection (LOD) of 2.5−48.5 pg and limit of …
-
Ανάπτυξη μεθόδων προσδιορισμού κυανοτοξινών και οργανικών ρύπων σε νερά με υγροχρωματογραφία - συζευγμένη φασματομετρία μαζών
… mass spectrometry (LC–MS/MS) in MRM mode. A dual Solid Phase Extraction (SPE) cartridge assembly (two tandem SPE cartridges, Oasis HLB and Hyper PGC) was applied for the efficient extraction of target compounds from water. Moreover, a method was developed for the simultaneous …
-
Development of an Analytical Method for VInca Alkaloids Using Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
… per analyte in multiple reaction monitoring (MRM) mode. Calibrators in methanol resulted in a LLOQ for vinblastine of approximately 0.77 ng/mL and of deacetylvinblastine at approximately 3.6 ng/mL. The LLOQ for plasma samples after SPE was 0.4450.047 for VBL and 0.2090.01 ng/mL for DVBL. The …
-
Quantificação de resíduos de amoxicilina e ampicilina por injeção direta de amostras de leite de bovino
… As well as, columns with different modes and mechanism of the analytes retention (C8, C18, SAX, SCX) were used. Using the technique of column coupling and a mass spectrometer as detector, ampicillin, was quantified, in bovine milk samples having a RAM-BSA column, in the first …
-
DEVELOPMENT OF A LC/MS-MS METHOD FOR THE STUDY OF THE RATIOS BETWEEN MORPHINE, MORPHINE-3-beta-D-GLUCURONIDE AND MORPHINE-6-beta-D-GLUCURONIDE IN BLOOD SAMPLES FROM HEROIN FATALITIES".
… operating in positive ionisation and MRM mode, was used. Chromatographic separation was achieved thanks to a Reversed-Phase method, using a C18 column and a gradient elution with a binary mobile phase. SPE technique was employed to extract the analytes from biological samples. After …
-
Development of Liquid Chromatography-tandem Mass Spectrometry (Lc-ms/Ms) Methods for Exploration of Currency Contamination with Controlled Substances
… per analyte in multiple reaction monitoring (MRM) mode. The limit of quantitation for cocaine was 0.0664 ng/bill, codeine was 0.0742 ng/bill, heroin was 0.0743 ng/bill, 3,4-methylenedioxymethamphetamine (MDMA) was 0.0730 ng/bill, methamphetamine was 0.0639 ng/bill, and morphine was 0.0268 …
-
New synthetic bile acid analogue agonists of FXR and TGR5 receptors: Analytical methodologies for the study of their physico-chemical properties, pharmacokinetic activity and metabolism.
… and metabolism using a bile fistula rat model. Sensitive and accurate analytical methods have been developed for the quali-quantitative analysis of BA in biological fluids and sample used for physicochemical studies. Combined High Performance Liquid Chromatography Electrospray tandem mass …
-
Métodos para a determinação enantiomérica dos fármacos omeprazol, lansoprazol e pantoprazol em águas residuais e de estuário
… gel® G3000PWXL), and those obtained in in-line mode with the RAM-BSA. Through a calibration curve, using standards of sodium polystyrene sulfonates of different molecular weights, in order of the 18000 Da, the molecular weight of eluted fractions were determined. This work reports the …
-
Analysis of Glycerophospholipids and Sphingolipids in Murine Brain Using Liquid Chromatography – Electrospray Ionization - Tandem Mass Spectrometry and Matrix-Assisted Laser Desorption Ionization – Imaging Mass Spectrometry
… spectrometer and multiple-reaction-monitoring (MRM) mode, the glycerophosphocholine (GPC) metabolites and second messengers in the hippocampus of N3 & N4 C57BL/6 x 129/SV were profiled at various post-mortem interval (PMI). I found that disruption to the GPC metabolite and second messengers …
-
Ανάπτυξη μεθόδων προσδιορισμού ορμονών με αυξητική δράση σε βιολογικά δείγματα με υγρή χρωματογραφία-φασματομετρία μαζών
… and negative multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for the unambiguous confirmation of the hormones. The method was validated according to the Commission Decision 2002/657/EC, at the validation level of 0.5 ng/g. …
-
Development of liquid chromatography-mass spectrometry protocols for quantification of imidacloprid in pig urine and for analysis of 5α-cyprinol sulfate metabolism in zebrafish
… tandem MS/MS and multiple reaction monitoring (MRM) mode that created specific channels to monitor previously identified daughter ions of IMI and the internal standard D4-IMI. The subsequent LC/MS utilization first required purification of 5α-cyprinol sulfate, the main bile alcohol present in …
-
Development and validation of selective and sensitive LC-MS/MS Methods for determination of para-aminosalicyclic acid and cycloserine/terizidone applicable to clinical studies for the treatment of tuberculosis
… resolution in the multiple reaction monitoring (MRM) mode was used to monitor the transition of the protonated precursor ions m/z 154.1 and m/z 181.2 to the product ions m/z 80.2 and m/z 95.2 for PAS and the ISTD, respectively. Electro Spray Ionisation (ESI) was used for ion production. Accuracy …
-
The Role of RNASE L in Type I Diabetes and Development of Quantitative LC-MS/MS Methods for the Pharmacological Studies of Anti-Cancer Drug Candidates
… 5500 with positive electrospray ionization. A MRM mode was chosen for sensitive and specific detection of the analyte and internal standard. The HPLC separation employed a Phenomenex Kinetex C8 column (50x2.1 mm, 2.6µ) with a gradient mobile phase of 0.2% formic acid in water and 0.2% formic …
-
Quantification of C₂₋₃ organosulfates in atmospheric aerosols : method comparison and evaluation
… data of C<sub>2-3</sub>OSs allows for refined modeling of isoprene chemistry, enabling a more accurate perception of its broader implications in atmospheric processes. Despite the importance of airborne C<sub>2-3</sub>OSs, few unambiguous measurements of these compounds have been conducted, …
-
Profiling of bioactive lipids using ultrahigh performance liquid chromatography and mass spectrometry
… mass analyzer in multiple reaction monitoring (MRM) mode for selective and sensitive identification of sweeteners. Prior to this selective MS/MS detection, a rapid ultra-high performance liquid chromatographic separation was performed using a fused-core C18 column to elute and resolve sweeteners …
-
Validation of an ultra performance liquid chromatography tandem mass spectrometry (UPLC™/MS/MS) method for forensic toxicological analysis : Confirmation and quantitation of lysergic acid diethylamide (LSD) and its congeners in forensic samples
… (ESI+) in multiple reaction monitoring (MRM) mode. The lowest limit of quantitation (LLOQ) was 20 pg/mL for LSD and iso-LSD, and 50 pg/mL for nor-LSD and O-H-LSD. The method was linear, accurate, precise, selective, and reproducible from 20 to 2000 pg/mL for LSD and iso-LSD, and from 50 …
Page 1 of 2